Full-field laser heterodyne imaging vibrometry using a CMOS-DVR system

被引:3
|
作者
Xiao, Wen [1 ]
Chen, Zonghui [1 ]
Pan, Feng [1 ]
Hou, Xueqin [1 ]
Hao, Hongliang [1 ]
Guo, Zhuang [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Key Lab Precis Optomechatron Technol, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
DOPPLER VIBROMETRY; HOLOGRAPHIC-INTERFEROMETRY; SPECKLE NOISE; SIDE-BAND; VIBRATION; PHASE; AMPLITUDE; DIRECTION; EXCITATION; FREQUENCY;
D O I
10.1364/AO.431321
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A laser heterodyne imaging vibrometry is proposed for full-field vibration measurement. The vibration responses are imaged and recorded using a CMOS camera and a digital video recorder. A digital demodulation method based on a cumulative distribution function and autocorrelation is designed to demodulate signals affected by speckle noise. The experimental investigations confirm the viability of the proposed method for vibration measurement. Meanwhile, a comparison with laser Doppler vibrometry is performed to further validate the method. The results prove the proposed vibrometry is an effective and precise option for full-field vibration measurement. (C) 2021 Optical Society of America
引用
收藏
页码:8513 / 8523
页数:11
相关论文
共 50 条
  • [21] Full-field heterodyne interference microscope with spatially incoherent illumination
    Pitter, MC
    See, CW
    Somekh, MG
    OPTICS LETTERS, 2004, 29 (11) : 1200 - 1202
  • [22] Application of heterodyne interferometry for the full-field surface shape measurement
    Józwicki, R
    Tkaczyk, T
    12TH CZECH-SLOVAK-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2001, 4356 : 182 - 186
  • [23] Video-rate, full-field OCT imaging using a dual-channel parallel heterodyne detection technique
    Akiba, M
    Chan, KP
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 12 - 13
  • [24] Two-wavelength full-field heterodyne interferometric profilometry
    Hsieh, Hung-Chih
    Chen, Yen-Liang
    Jian, Zhi-Chen
    Wu, Wang-Tsung
    Su, Der-Chin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (02)
  • [25] Characterizing an Image Intensifier in a Full-Field Range Imaging System
    Payne, Andrew D.
    Dorrington, Adrian A.
    Cree, Michael J.
    Carnegie, Dale A.
    IEEE SENSORS JOURNAL, 2008, 8 (11-12) : 1763 - 1770
  • [26] Full-field time domain optical molecular imaging system
    Hall, DJ
    Vera, DR
    Mattrey, RF
    Optical Tomography and Spectroscopy of Tissue VI, 2005, 5693 : 330 - 335
  • [27] A high-resolution full-field range imaging system
    Carnegie, DA
    Cree, MJ
    Dorrington, AA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (08): : 1 - 7
  • [28] Improved linearity using harmonic error rejection in a full-field range imaging system
    Payne, Andrew D.
    Dorrington, Adrian A.
    Cree, Michael J.
    Carnegie, Dale A.
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS 2008, 2008, 6805
  • [29] Full-field quantitative phase imaging
    DiMarzio, Charles A.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XV, 2008, 6861
  • [30] Full-Field Imaging With Quantum Illumination
    Gregory, T.
    Moreau, P-A
    Toninelli, E.
    Padgett, M. J.
    2020 PHOTONICS NORTH (PN), 2020,