Full-field laser heterodyne imaging vibrometry using a CMOS-DVR system

被引:2
|
作者
Xiao, Wen [1 ]
Chen, Zonghui [1 ]
Pan, Feng [1 ]
Hou, Xueqin [1 ]
Hao, Hongliang [1 ]
Guo, Zhuang [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Key Lab Precis Optomechatron Technol, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
DOPPLER VIBROMETRY; HOLOGRAPHIC-INTERFEROMETRY; SPECKLE NOISE; SIDE-BAND; VIBRATION; PHASE; AMPLITUDE; DIRECTION; EXCITATION; FREQUENCY;
D O I
10.1364/AO.431321
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A laser heterodyne imaging vibrometry is proposed for full-field vibration measurement. The vibration responses are imaged and recorded using a CMOS camera and a digital video recorder. A digital demodulation method based on a cumulative distribution function and autocorrelation is designed to demodulate signals affected by speckle noise. The experimental investigations confirm the viability of the proposed method for vibration measurement. Meanwhile, a comparison with laser Doppler vibrometry is performed to further validate the method. The results prove the proposed vibrometry is an effective and precise option for full-field vibration measurement. (C) 2021 Optical Society of America
引用
收藏
页码:8513 / 8523
页数:11
相关论文
共 50 条
  • [1] Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera
    Serov, A
    Steinacher, B
    Lasser, T
    [J]. OPTICS EXPRESS, 2005, 13 (10): : 3681 - 3689
  • [2] A full-field heterodyne surface plasmon resonance dynamic bio-imaging system
    Lin, C. -H.
    Su, Y. -D.
    Huang, C. -H.
    Cho, K. -C.
    Chen, S. -J.
    [J]. NANOSCALE IMAGING, SPECTROSCOPY, SENSING, AND ACTUATION FOR BIOMEDICAL APPLICATIONS IV, 2007, 6447
  • [3] Full-field vibrometry with digital Fresnel holography
    Leval, J
    Picart, P
    Boileau, JP
    Pascal, JC
    [J]. APPLIED OPTICS, 2005, 44 (27) : 5763 - 5772
  • [4] FULL-FIELD VIBROMETRY USING A FABRY-PEROT ETALON INTERFEROMETER
    OURSLER, DA
    WAGNER, JW
    [J]. APPLIED OPTICS, 1992, 31 (34): : 7301 - 7308
  • [5] Measurement of dynamic full-field internal stresses through surface laser Doppler vibrometry
    Holland, Stephen D.
    Renshaw, Jeremy
    Roberts, Ron
    [J]. APPLIED PHYSICS LETTERS, 2007, 91 (13)
  • [6] Optimal condition for full-field heterodyne interferometry
    Jian, Zhi-Cheng
    Chen, Yen-Liang
    Hsieh, Hung-Chih
    Hsieh, Po-Jen
    Su, Der-Chin
    [J]. OPTICAL ENGINEERING, 2007, 46 (11)
  • [7] Full-field heterodyne interferometer for shape measurement:: experimental characteristics of the system
    Tkaczyk, T
    Józwicki, R
    [J]. OPTICAL ENGINEERING, 2003, 42 (08) : 2391 - 2399
  • [8] Full-field laser Doppler blood-flow imaging and monitoring using an intelligent CMOS camera and area illumination
    Serov, A
    Steinacher, B
    Lasser, T
    [J]. SARATOV FALL MEETING 2004: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE VI, 2005, 5771 : 95 - 102
  • [9] Analysis on optical heterodyne frequency error of full-field heterodyne interferometer
    Li, Yang
    Zhang, Wenxi
    Wu, Zhou
    Lv, Xiaoyu
    Kong, Xinxin
    Guo, Xiaoli
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [10] Laser Doppler Vibrometry system using the synthetic-heterodyne interferometric demodulation scheme implemented on a CMOS DSP camera
    Connelly, M. J.
    Szecowka, P. M.
    Jallapuram, R.
    Martin, S.
    Toal, V.
    Whelan, M. P.
    [J]. CSNDSP 08: PROCEEDINGS OF THE SIXTH INTERNATIONAL SYMPOSIUM ON COMMUNICATION SYSTEMS, NETWORKS AND DIGITAL SIGNAL PROCESSING, 2008, : 133 - +