Robustness of sweeping-window arc therapy treatment sequences against intrafractional tumor motion

被引:5
|
作者
Fleckenstein, Jens [1 ]
Hesser, Juergen [1 ]
Wenz, Frederik [1 ]
Lohr, Frank [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
关键词
VMAT; robust planning; interplay effects; organ motion; time resolved dosimetry; INCORPORATING ORGAN MOTION; VOLUMETRIC MODULATED ARC; RESPIRATORY MOTION; STATISTICAL-ANALYSIS; RADIATION-THERAPY; DOSIMETRIC IMPACT; DOSE DISTRIBUTION; LUNG-CANCER; MONTE-CARLO; IMRT;
D O I
10.1118/1.4914166
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Due to the potentially periodic collimator dynamic in volumetric modulated arc therapy (VMAT) dose deliveries with the sweeping-window arc therapy (SWAT) technique, additional manifestations of dosimetric deviations in the presence of intrafractional motion may occur. With a fast multileaf collimator (MLC), and a flattening filter free dose delivery, treatment times close to 60 s per fraction are clinical reality. For these treatment sequences, the human breathing period can be close to the collimator sweeping period. Compared to a random arrangement of the segments, this will cause a further degradation of the dose homogeneity. Methods: Fifty VMAT sequences of potentially moving target volumes were delivered on a two dimensional ionization chamber array. In order to detect interplay effects along all three coordinate axes, time resolved measurements were performed twice-with the detector aligned in vertical (V) or horizontal (H) orientation. All dose matrices were then moved within a simulation software by a time-dependent motion vector. The minimum relative equivalent uniform dose EUDr,m for all breathing starting phases was determined for each amplitude and period. Furthermore, an estimation of periods with minimum EUD was performed. Additionally, LINAC logfiles were recorded during plan delivery. The MLC, jaw, gantry angle, and monitor unit settings were continuously saved and used to calculate the correlation coefficient between the target motion and the dose weighed collimator motion component for each direction (CC, LR, AP) separately. Results: The resulting EUDr,m were EUDr,m(CCV) = (98.3 +/- 0.6)%, EUDr,m(CCH) = (98.6 +/- 0.5)%, EUDr,m(AP(V)) = (97.7 +/- 0.9)%, and EUDr,m(LRH) = (97.8 +/- 0.9)%. The overall minimum relative EUD observed for 360. arc midventilation treatments was 94.6%. The treatment plan with the shortest period and a minimum relative EUD of less than 97% was found at T = 6.1 s. For a partial 120 degrees arc, an EUDr,m = 92.0% was found. In all cases, a correlation coefficient above 0.5 corresponded to a minimum in EUD. Conclusions: With the advent of fast VMAT delivery techniques, nonrobust treatment sequences for human breathing patterns can be generated. These sequences are characterized by a large correlation coefficient between a target motion component and the corresponding collimator dynamic. By iteratively decreasing the maximum allowed dose rate, a low correlation coefficient and consequentially a robust treatment sequence are ensured. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页码:1538 / 1545
页数:8
相关论文
共 50 条
  • [31] Observations on prostate intrafraction motion and the effect of reduced treatment time using volumetric modulated arc therapy
    Shelton, Jay
    Rossi, Peter J.
    Chen, Hao
    Liu, Yuan
    Master, Viraj A.
    Jani, Ashesh B.
    PRACTICAL RADIATION ONCOLOGY, 2011, 1 (04) : 243 - 250
  • [32] A treatment planning study comparing tomotherapy, volumetric modulated arc therapy, Sliding Window and proton therapy for low-risk prostate carcinoma
    Scobioala, Sergiu
    Kittel, Christopher
    Wissmann, Nicolas
    Haverkamp, Uwe
    Channaoui, Mohammed
    Habibeh, Omar
    Elsayad, Khaled
    Eich, Hans Theodor
    RADIATION ONCOLOGY, 2016, 11
  • [33] A treatment planning study comparing tomotherapy, volumetric modulated arc therapy, Sliding Window and proton therapy for low-risk prostate carcinoma
    Sergiu Scobioala
    Christopher Kittel
    Nicolas Wissmann
    Uwe Haverkamp
    Mohammed Channaoui
    Omar Habibeh
    Khaled Elsayad
    Hans Theodor Eich
    Radiation Oncology, 11
  • [34] Planning Automation for Treatment Techniques Comparison and Robustness Analysis: Tangential Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Whole Breast Irradiation
    Marrazzo, Livia
    Chila, Deborah
    Vanore, Immacolata
    Pellegrini, Roberto
    Voet, Peter
    Di Cataldo, Vanessa
    Meattini, Icro
    Zani, Margherita
    Arilli, Chiara
    Calusi, Silvia
    Casati, Marta
    Compagnucci, Antonella
    Talamonti, Cinzia
    Livi, Lorenzo
    Pallotta, Stefania
    ADVANCES IN RADIATION ONCOLOGY, 2025, 10 (03)
  • [35] Respiratory gating window and internal motion margins to accommodate the fluctuation of exhalation level during proton beam therapy for liver tumor
    Asada, Y.
    Fuji, H.
    Numano, M.
    Saida, T.
    Kawashima, I.
    Toi, A.
    Yamashita, H.
    Urakabe, E.
    Murayama, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S608 - S608
  • [36] Optimal prescription isodose line in SBRT for lung tumor treatment with volumetric-modulated arc therapy
    Wang, David
    Denittis, Albert
    Evans, Tracey
    Meyer, Thomas
    JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 157 - 164
  • [37] Tracking of organ motion during arc therapy with MV treatment beam imaging and as-needed kV imaging
    Liu, W.
    Mao, W.
    Wiersma, R.
    Luxton, G.
    Riaz, N.
    Schlaefer, A.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S609 - S609
  • [38] Stereotactic radiation treatment planning with volumetric modulated arc therapy: Impact of duodenal sparing on pancreatic tumor coverage
    Kumar, R.
    Kang, J.
    Herman, J. M.
    Tuli, R.
    Pawlik, T. M.
    Tryggestad, E.
    Smith, K.
    DeWeese, T. L.
    Wong, J.
    Ford, E. C.
    JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (04)
  • [39] Efficacy Assessment of Breathing Phase Adaptive Lung Tumor Motion Management for Various Degrees of Freedom in Volumetric Modulated Arc Therapy (VMAT)
    Tewatia, D.
    Chebrolu, V.
    Tolakanahalli, R.
    Paliwal, B.
    Tome, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S846 - S847
  • [40] Synchronized moving aperture radiation therapy (SMART): superimposing tumor motion on IMRT MLC leaf sequences under realistic delivery conditions
    Xu, Jun
    Papanikolaou, Nikos
    Shi, Chengyu
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16): : 4993 - 5007