Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET

被引:71
|
作者
Gu, Y. [1 ,2 ]
Matteson, J. L. [3 ]
Skelton, R. T. [3 ]
Deal, A. C. [3 ]
Stephan, E. A. [3 ]
Duttweiler, F. [3 ]
Gasaway, T. M. [3 ]
Levin, C. S. [1 ,2 ,4 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Mol Imaging Instrumentat Lab, Stanford, CA 94305 USA
[3] Univ Calif San Diego, Ctr Astrophys & Space Sci, La Jolla, CA 92093 USA
[4] Stanford Univ, Dept Phys, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 06期
关键词
PERFORMANCE EVALUATION; SENSITIVITY; SYSTEM;
D O I
10.1088/0031-9155/56/6/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm x 40 mm x 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and energy resolution. The study found a single anode FWHM energy resolution of 3.06 +/- 0.39% at 511 keV throughout most of the detector volume. Improved resolution is expected with properly shielded front-end electronics. Measurements made using a collimated beam established the efficacy of the steering electrodes in facilitating enhanced charge collection across anodes, as well as a spatial resolution of 0.44 +/- 0.07 mm in the direction orthogonal to the electrode planes. Finally, measurements based on coincidence electronic collimation yielded a point spread function with 0.78 +/- 0.10 mm FWHM, demonstrating 1 mm spatial resolution capability transverse to the anodes-as expected from the 1 mm anode pitch. These findings indicate that the CZT-based detector concept has excellent performance and shows great promise for a high-resolution PET system.
引用
下载
收藏
页码:1563 / 1584
页数:22
相关论文
共 50 条
  • [31] Investigation of a high-resolution detector for wholebody PET imaging
    Surti, Suleman
    Kuhn, Austin
    Karp, Joel S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1601 - 1605
  • [32] A high-resolution PET detector based on continuous scintillators
    Tavernier, S
    Bruyndonckx, P
    Leonard, S
    Devroede, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 321 - 325
  • [33] Experiments and Monte Carlo modeling of a higher resolution Cadmium Zinc Telluride detector for safeguards applications
    Borella, Alessandro
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15), 2016, 44
  • [34] NATIVE TELLURIUM DIOXIDE LAYER ON CADMIUM TELLURIDE - A HIGH-RESOLUTION ELECTRON-MICROSCOPY STUDY
    PONCE, FA
    SINCLAIR, R
    BUBE, RH
    APPLIED PHYSICS LETTERS, 1981, 39 (12) : 951 - 953
  • [35] Photonic THz InISAR for 3D Positioning With High Resolution
    Yang, Zuomin
    Zhang, Lu
    Zhang, Hongqi
    Yang, Hang
    Lyu, Zhidong
    Yu, Xianbin
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2023, 41 (10) : 2999 - 3006
  • [36] A cadmium-zinc-telluride strip detector for high-energy diffraction applications
    Siddons, DP
    Camarda, G
    Kakuno, E
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 965 - 968
  • [37] PERFORMANCE OF QPET, A HIGH-RESOLUTION 3D PET IMAGING-SYSTEM FOR SMALL VOLUMES
    MCKEE, BTA
    DICKSON, AW
    HOWSE, DC
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 176 - 185
  • [38] Maximum likelihood positioning algorithm for high-resolution PET scanners
    Gross-Weege, Nicolas
    Schug, David
    Hallen, Patrick
    Schulz, Volkmar
    MEDICAL PHYSICS, 2016, 43 (06) : 3049 - 3061
  • [39] High-Resolution 3D Radial bSSFP with IDEAL
    Moran, Catherine J.
    Brodsky, Ethan K.
    Bancroft, Leah Henze
    Reeder, Scott B.
    Yu, Huanzhou
    Kijowski, Richard
    Engel, Dorothee
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 95 - 104
  • [40] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738