APPLICATION OF FLOW CYTOMETER IN SECONDARY STICKIES

被引:0
|
作者
Jiang Guobin [1 ]
Chen Zhonghao [1 ]
机构
[1] S China Univ Technol, State Key Lab Pulp & Paper Engn, Guangzhou 510640, Peoples R China
关键词
flow cytometer; stickies; secondary stickies; turbidity meter;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Three different cationic fixatives A159, A160 and A169 were added to OCC pulp suspension, and the amount of dissolved and colloidal materials (DCM) within stock was estimated by Turbidity Meter and Flow Cytometer (FCM) respectively. Results might provide the insight into the advantage of FCM during the DCM testing. Results showed that turbidity of three samples all descended greatly compared with pre-treatment, but no significant differences were found when testing with Turbidimeter. Via the FCM, results demonstrated that the amounts of DCM were much less than pre-treatment, but the size keeps almost unchanged for the treatment of good fixation. For poor fixation, DCM amounts decreased, but the size was bigger than pre-treatment. This might result from destabilization of colloidal system, and this destabilization could not be observed by Turbidimeter. Therefore, different fixation performances of cationic fixatives could be well represented via the FCM, which would help to exactly estimate the amount and deposition of DCM in the pulp suspension.
引用
收藏
页码:1068 / 1071
页数:4
相关论文
共 50 条
  • [41] Purification of fish spermatogonia using flow cytometer
    Kise, Kazuyoshi
    Miwa, Misako
    Yoshizaki, Goro
    JOURNAL OF REPRODUCTION AND DEVELOPMENT, 2008, 54 (01): : A8 - A8
  • [42] Miniaturized On-Sensor Fluorescence Flow Cytometer
    Shanmugam, Akshaya
    Salthouse, Christopher D.
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 2019 - 2022
  • [43] PURCHASING TIPS WHEN SEARCHING FOR A FLOW CYTOMETER
    Reddy, Emily C.
    Lab Manager, 2022, 17 (01):
  • [44] INTEGRATION OF A BARCODE READER WITH A COMMERCIAL FLOW CYTOMETER
    ROBINSON, JP
    MAGUIRE, D
    KING, G
    KELLEY, S
    DURACK, G
    CYTOMETRY, 1992, 13 (02): : 193 - 197
  • [45] Validation of a flow cytometer for use in regulated studies
    Hill, Benjaman
    Thomas, John K.
    Schroeder, Michelle
    Ferbas, John
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2006, 70B (05) : 369 - 369
  • [46] A portable flow cytometer for the detection and identification of microorganisms
    Davey, HM
    Kell, DB
    RAPID METHODS FOR ANALYSIS OF BIOLOGICAL MATERIALS IN THE ENVIRONMENT, 2000, 30 : 159 - 167
  • [47] Effect of DCS of BCTMP on the stability and depositability of secondary stickies in deinked pulp
    Li Zongquan
    Zhan Huaiyu
    Qin Menghua
    Research Progress in Pulping and Papermaking, 2006, 2006, : 278 - 282
  • [48] An All-Glass Microfluidic Flow Cytometer
    Li, Jiayu
    Cui, Yuhan
    Wei, Zewen
    Zhou, Tianfeng
    Li, Qin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XI, 2021, 11900
  • [50] MACINTOSH GRAPHICS FOR THE EPICS FLOW CYTOMETER USER
    CAMERON, MJ
    CYTOMETRY, 1990, 11 (08): : 916 - 918