APPLICATION OF FLOW CYTOMETER IN SECONDARY STICKIES

被引:0
|
作者
Jiang Guobin [1 ]
Chen Zhonghao [1 ]
机构
[1] S China Univ Technol, State Key Lab Pulp & Paper Engn, Guangzhou 510640, Peoples R China
关键词
flow cytometer; stickies; secondary stickies; turbidity meter;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Three different cationic fixatives A159, A160 and A169 were added to OCC pulp suspension, and the amount of dissolved and colloidal materials (DCM) within stock was estimated by Turbidity Meter and Flow Cytometer (FCM) respectively. Results might provide the insight into the advantage of FCM during the DCM testing. Results showed that turbidity of three samples all descended greatly compared with pre-treatment, but no significant differences were found when testing with Turbidimeter. Via the FCM, results demonstrated that the amounts of DCM were much less than pre-treatment, but the size keeps almost unchanged for the treatment of good fixation. For poor fixation, DCM amounts decreased, but the size was bigger than pre-treatment. This might result from destabilization of colloidal system, and this destabilization could not be observed by Turbidimeter. Therefore, different fixation performances of cationic fixatives could be well represented via the FCM, which would help to exactly estimate the amount and deposition of DCM in the pulp suspension.
引用
收藏
页码:1068 / 1071
页数:4
相关论文
共 50 条
  • [31] Progress in Standardization of Fluorescence Flow Cytometer
    Lue Yingkai
    Liu Wenli
    Hu Zhixiong
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (04)
  • [32] Hydrodynamic focusing for a micromachined flow cytometer
    Hung, CI
    Ke, BJ
    Huang, GR
    Hwei, BH
    Lai, HF
    Lee, GB
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 672 - 679
  • [33] The antioxidation microsphere flow cytometer assay
    Thornthwaite, Jerry T.
    Shah, Hare R.
    CANCER RESEARCH, 2013, 73 (08)
  • [34] HIGH-EFFICIENCY FLOW CYTOMETER
    SKOGENHAGENSON, MJ
    SALZMAN, GC
    MULLANEY, PF
    BROCKMAN, WH
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1977, 25 (07) : 784 - 789
  • [35] Microfluidic impedance flow cytometer leveraging virtual constriction microchannel and its application in leukocyte differential
    Wang, Minruihong
    Zhang, Jie
    Chen, Xiao
    Li, Yimin
    Huang, Xukun
    Wang, Junbo
    Li, Yueying
    Huo, Xiaoye
    Chen, Jian
    Microsystems and Nanoengineering, 2024, 10 (01):
  • [36] INCREASING THE USE OF SECONDARY FIBER - AN OVERVIEW OF DEINKING CHEMISTRY AND STICKIES CONTROL
    OLSON, CR
    LETSCHER, MK
    APPITA JOURNAL, 1992, 45 (02): : 125 - 130
  • [37] Application of Cytosense flow cytometer for the analysis of airborne bacteria collected by a high volume impingement sampler
    Jang, Jaeyoun
    Hendriksen, Niels Bohse
    Jakobsen, Hans H.
    Gosewinkel, Ulrich
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 154 : 63 - 72
  • [38] New method for measuring potential secondary stickies in deinked pulp filtrates
    Sarja, T
    Zabihian, M
    Kourunen, P
    Niinimäki, J
    WATER SCIENCE AND TECHNOLOGY, 2004, 50 (03) : 207 - 215
  • [39] DETERMINE THE POTENCY OF BCG VACCINES BY FLOW CYTOMETER
    Yang, Yi-Chen
    Tsai, Mong-Hsun
    Cheng, Hwei-Fang
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2011, 25 (02) : 2394 - 2398
  • [40] Evaluating the liquid path stability of a flow cytometer
    Zhang, Wenchang
    Zhu, Lianqing
    Zhang, Fan
    Lou, Xiaoping
    Liu, Chao
    Meng, Xiaochen
    CYTOMETRY PART A, 2016, 89A (10) : 941 - 948