Complications After Arthroscopic Coracoclavicular Reconstruction Using a Single Adjustable-Loop-Length Suspensory Fixation Device in Acute Acromioclavicular Joint Dislocation

被引:82
|
作者
Shin, Sang-Jin [1 ]
Kim, Nam-Ki [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Dept Orthopaed Surg, Global Top Res Program 5, Seoul 158710, South Korea
关键词
STABILIZATION; SEPARATIONS; REDUCTION; SUTURE;
D O I
10.1016/j.arthro.2014.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustableeloop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Methods: Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. Results: The preoperative CC distance of the injured shoulder was 16.1 +/- 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% +/- 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 +/- 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% +/- 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 +/- 4.5) and 12 patients with reduction maintenance (98.4 +/- 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Conclusions: Satisfactory clinical outcomes were obtained after CC fixation using the single adjustableeloop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation. Additionally, 8 patients (44%) had complications associated with the adjustableeloop-length suspensory fixation device and surgical technical problems. Despite acceptable shoulder function restoration, adequate care should be exercised in surgical treatment of acute acromioclavicular dislocation with a single adjustableeloop-length suspensory fixation device for optimal radiological outcomes.
引用
下载
收藏
页码:816 / 824
页数:9
相关论文
共 47 条
  • [1] Comments on Complications After Arthroscopic Coracoclavicular Reconstruction Using a Single Adjustable Loop Length Suspensory Fixation Device
    Imhoff, Andreas B.
    Braun, Sepp
    Beitzel, Knut
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (06): : 1031 - 1033
  • [2] Comments on Complications After Arthroscopic Coracoclavicular Reconstruction Using a Single Adjustable Loop Length Suspensory Fixation Device Reply
    Shin, Sang-Jin
    Kim, Nam-Ki
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (06): : 1033 - 1034
  • [3] Arthroscopic Coracoclavicular and Acromioclavicular Stabilization of Acute Acromioclavicular Joint Dislocation By Suspensory Fixation System
    Martetschlaeger, Frank
    Tauber, Mark
    Habermeyer, Peter
    Selim, Hisham Anis
    ARTHROSCOPY TECHNIQUES, 2019, 8 (06): : E611 - E615
  • [4] Arthroscopic Acromioclavicular Joint Treatment With Coracoclavicular Fixation and Allograft Coracoclavicular Ligament Reconstruction for Acute Acromioclavicular Dislocations
    Ruzbarsky, Joseph J.
    Nolte, Philip-C
    Arner, Justin W.
    Elrick, Bryant P.
    Tross, Anna-K
    Millett, Peter J.
    ARTHROSCOPY TECHNIQUES, 2020, 9 (09): : E1219 - E1225
  • [5] Clavicular Tunnel Complications after Coracoclavicular Reconstruction in Acute Acromioclavicular Dislocation: Coracoid Loop versus Coracoid Tunnel Fixation
    Jeon, Neunghan
    Choi, Nam Hong
    Ha, Joo Hyung
    Kim, Myonghwhan
    Lim, Tae Kang
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 128 - 135
  • [6] Assessment of Coracoclavicular Ligament Healing on MRI After Arthroscopic TightRope Fixation for Acute Acromioclavicular Joint Dislocation
    Elhalawany, Mohamed Fathy
    Abdalla, Usama Gaber
    Shwitter, Lotfy
    Elattar, Mohammed Said
    Fahmy, Fahmy Samir
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (10)
  • [7] Arthroscopic Coracoclavicular Fixation Using Multiple Low-Profile Devices in Acute Acromioclavicular Joint Dislocation
    Lee, Seung-Jin
    Yoo, Yon-Sik
    Kim, Yoon-Sang
    Jang, Seong-Wook
    Kim, Jeehyoung
    Kim, Sung-Jae
    Kim, Byung-Su
    Jung, Koo-Hyun
    Varshney, Ankit
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (01): : 14 - 21
  • [8] Arthroscopic Iliac Crest Bone Block for Reconstruction of the Glenoid: A Fixation Technique Using an Adjustable-Length Loop Cortical Suspensory Fixation Device
    Kalogrianitis, Socrates
    Tsouparopoulos, Vasileios
    ARTHROSCOPY TECHNIQUES, 2016, 5 (06): : E1197 - E1202
  • [9] Transglenoid Fixation Technique for Arthroscopic Subscapularis Augmentation Using an Adjustable-Length Loop Cortical Suspensory Fixation Device
    Ren, Shiyou
    Zhou, Ri
    Guan, Siyao
    Zhang, Wentao
    ARTHROSCOPY TECHNIQUES, 2023, 12 (09): : E1555 - E1563
  • [10] Arthroscopic fixation for acute acromioclavicular joint disruption using the TightRope device
    Chaudhary, Deepak
    Jain, Vineet
    Joshi, Deepak
    Jain, Jitesh Kumar
    Goyal, Ankit
    Mehta, Nitin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (03) : 309 - 314