Complications After Arthroscopic Coracoclavicular Reconstruction Using a Single Adjustable-Loop-Length Suspensory Fixation Device in Acute Acromioclavicular Joint Dislocation

被引:82
|
作者
Shin, Sang-Jin [1 ]
Kim, Nam-Ki [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Dept Orthopaed Surg, Global Top Res Program 5, Seoul 158710, South Korea
关键词
STABILIZATION; SEPARATIONS; REDUCTION; SUTURE;
D O I
10.1016/j.arthro.2014.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustableeloop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Methods: Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. Results: The preoperative CC distance of the injured shoulder was 16.1 +/- 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% +/- 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 +/- 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% +/- 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 +/- 4.5) and 12 patients with reduction maintenance (98.4 +/- 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Conclusions: Satisfactory clinical outcomes were obtained after CC fixation using the single adjustableeloop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation. Additionally, 8 patients (44%) had complications associated with the adjustableeloop-length suspensory fixation device and surgical technical problems. Despite acceptable shoulder function restoration, adequate care should be exercised in surgical treatment of acute acromioclavicular dislocation with a single adjustableeloop-length suspensory fixation device for optimal radiological outcomes.
引用
下载
收藏
页码:816 / 824
页数:9
相关论文
共 47 条
  • [31] A retrospective comparative study of arthroscopic fixation in acute Rockwood type IV acromioclavicular joint dislocation: single versus double paired Endobutton technique
    Jian Xu
    Haifeng Liu
    Wei Lu
    Dingfu Li
    Weimin Zhu
    Kan Ouyang
    Bing Wu
    Liangquan Peng
    Daping Wang
    BMC Musculoskeletal Disorders, 19
  • [32] Can an adjustable-loop length suspensory fixation device reduce femoral tunnel enlargement in anterior cruciate ligament reconstruction? A prospective computer tomography study
    Lanzetti, R. M.
    Monaco, E.
    De Carli, A.
    Grasso, A.
    Ciompi, A.
    Sigillo, R.
    Argento, G.
    Ferretti, A.
    KNEE, 2016, 23 (05): : 837 - 841
  • [33] Clinical and radiologic outcomes of the modified phemister procedure with coracoclavicular ligament augmentation using mersilene tape versus hook plate fixation for acute acromioclavicular joint dislocation
    Yu-Jui Chang
    Wen-Yi Chou
    Jih-Yang Ko
    Hao-Chen Liu
    Ya-Ju Yang
    Ka-Kit Siu
    BMC Surgery, 22
  • [34] Clinical and radiologic outcomes of the modified phemister procedure with coracoclavicular ligament augmentation using mersilene tape versus hook plate fixation for acute acromioclavicular joint dislocation
    Chang, Yu-Jui
    Chou, Wen-Yi
    Ko, Jih-Yang
    Liu, Hao-Chen
    Yang, Ya-Ju
    Siu, Ka-Kit
    BMC SURGERY, 2022, 22 (01)
  • [35] Anterior Laxity at 2 Years After Anterior Cruciate Ligament Reconstruction Is Comparable When Using Adjustable-Loop Suspensory Fixation and Interference Screw Fixation
    Boutsiadis, Achilleas
    Panisset, Jean-Claude
    Devitt, Brian M.
    Mauris, Frederic
    Barthelemy, Renaud
    Barth, Johannes
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (10): : 2366 - 2375
  • [36] Long-term follow-up in a single-bundle arthroscopic acromioclavicular joint reconstruction after Rockwood III to VI dislocation
    Reyniers, P.
    De Mulder, T.
    Ruette, P.
    Van Raebroeckx, A.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (01): : 156 - 161
  • [37] Transarticular fixation by hook plate versus coracoclavicular stabilization by single multistrand titanium cable for acute Rockwood grade-V acromioclavicular joint dislocation: a case–control study
    You-Shui Gao
    Yue-Lei Zhang
    Zi-Sheng Ai
    Yu-Qiang Sun
    Chang-Qing Zhang
    Wei Zhang
    BMC Musculoskeletal Disorders, 16
  • [38] Arthroscopic fixation of acute acromioclavicular joint disruption with TightRope™ : Outcome and complications after minimum 2 (2-5) years follow-up
    Zhang, Li-Feng
    Yin, Bo
    Hou, Su
    Han, Bing
    Huang, De-fa
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02)
  • [39] Transarticular fixation by hook plate versus coracoclavicular stabilization by single multistrand titanium cable for acute Rockwood grade-V acromioclavicular joint dislocation: a case-control study
    Gao, You-Shui
    Zhang, Yue-Lei
    Ai, Zi-Sheng
    Sun, Yu-Qiang
    Zhang, Chang-Qing
    Zhang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [40] Excellent bone plug-socket integration at 8 weeks after anterior cruciate ligament reconstruction using an adjustable-length loop cortical fixation device
    Uchida, Ryohei
    Nakamura, Norimasa
    Suzuki, Tomoyuki
    Kusano, Masashi
    Mae, Tatsuo
    Ohzono, Kenji
    Toritsuka, Yukiyoshi