Three-dimensional versus four-dimensional dose calculation for breast intensity-modulated radiation therapy

被引:4
|
作者
Chung, Joo-Hyun [1 ]
Chun, Minsoo [1 ,2 ,3 ]
Kim, Jung-In [1 ,2 ,3 ]
Park, Jong Min [1 ,2 ,3 ,4 ]
Shin, Kyung Hwan [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[2] Seoul Natl Univ, Biomed Res Inst, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[4] Adv Inst Convergence Technol, Robot Res Lab Extreme Environm, Suwon, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2020年 / 93卷 / 1110期
关键词
MONTE-CARLO; DOSIMETRIC IMPACT; BREATHING MOTION; HOLD TECHNIQUES; HEART-DISEASE; RADIOTHERAPY; CANCER; RESPIRATION; IRRADIATION; VALIDATION;
D O I
10.1259/bjr.20200047
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To analyze the effect of intra- and interfractional motion during breast intensity modulated radiation therapy (IMRT) by calculating dose distribution based on four-dimensional computed tomography (4DCT). Methods: 20 patients diagnosed with left breast cancer were enrolled. Three-dimensional CT (3DCT) along with 10 phases of 4DCT were collected for each patient, with target volumes independently delineated on both 3DCT and all phases of 4DCT. IMRT plans were generated based on 3DCT (43.2Gy in 16 fractions). The plan parameters for each segment were split into phases based on time duration estimates for each respiratory phase, with phase-specific dose distributions calculated and summated (4D-calculated dose). The procedure is repeated for 16 fractionations by randomly allocating starting phase using random-number generation to simulate interfractional discrepancy caused by different starting phase. Comparisons of plan quality between the original and 4D-calculated doses were analyzed. Results: There was a significant distortion in 4D-calculated dose induced by respiratory motion in terms of conformity and homogeneity index compared to those of the original 3D plan. Mean doses of the heart and the ipsilateral lung were significantly higher in the 4D-calculated doses compared to those of the original 3D plan (0.34 Gy, p = 0.010 and 0.59Gy, p < 0.001), respectively). The mean internal mammary lymph node (IMN) dose was significantly greater in the 4D-calculated plan, compared to the original 3D plan (1.42Gy, p < 0.001). Conclusions: IMN doses should be optimized during the dose-calculation for the free-breathing left breast IMRT. Advances in knowledge: The interplay effect between respiratory motion and multileaf collimator modulation caused discrepancies in dose distribution, particularly in IMN.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A Retrospective Comparison of Toxicity, Response and Survival of Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiation Therapy in the Treatment of Rectal Carcinoma
    Kouklidis, Georgios
    Nikolopoulos, Manolis
    Ahmed, Omer
    Eskander, Boulos
    Masters, Ben
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [32] Comparison of gamma index based on dosimetric error and clinically relevant dose-volume index based on three-dimensional dose prediction in breast intensity-modulated radiation therapy
    Kaneko, Akari
    Sumida, Iori
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Suzuki, Osamu
    Seo, Yuji
    Otani, Keisuke
    Tamari, Keisuke
    Ogawa, Kazuhiko
    [J]. RADIATION ONCOLOGY, 2019, 14 (1)
  • [33] Three-dimensional and four-dimensional printing in otolaryngology
    Irene Chiesa
    Carmelo De Maria
    Giovanni Vozzi
    Riccardo Gottardi
    [J]. MRS Bulletin, 2023, 48 : 676 - 687
  • [34] Three-dimensional and four-dimensional printing in otolaryngology
    Chiesa, Irene
    De Maria, Carmelo
    Vozzi, Giovanni
    Gottardi, Riccardo
    [J]. MRS BULLETIN, 2023, 48 (06) : 676 - 687
  • [35] Three-dimensional conformal intensity-modulated radiation therapy of left femur foci does not damage the sciatic nerve
    Xu, Wanlong
    Zhao, Xibin
    Wang, Qing
    Sun, Jungang
    Xu, Jiangbo
    Zhou, Wenzheng
    Wang, Hao
    Yan, Shigui
    Yuan, Hong
    [J]. NEURAL REGENERATION RESEARCH, 2014, 9 (20) : 1824 - 1829
  • [36] Three-dimensional conformal intensity-modulated radiation therapy of left femur foci does not damage the sciatic nerve
    Wanlong Xu
    Xibin Zhao
    Qing Wang
    Jungang Sun
    Jiangbo Xu
    Wenzheng Zhou
    Hao Wang
    Shigui Yan
    Hong Yuan
    [J]. Neural Regeneration Research, 2014, 9 (20) : 1824 - 1829
  • [37] The cost effectiveness of intensity-modulated radiation therapy and three-dimensional conformal radiotherapy in the treatment of head and neck cancers
    Varmaghani, Mehdi
    Amiri, Malihe
    Ebrahimpour, Hossein
    Salek, Roham
    Javan-Noughabi, Javad
    [J]. RADIATION ONCOLOGY, 2023, 18 (01)
  • [38] The cost effectiveness of intensity-modulated radiation therapy and three-dimensional conformal radiotherapy in the treatment of head and neck cancers
    Mehdi Varmaghani
    Malihe Amiri
    Hossein Ebrahimpour
    Roham Salek
    Javad Javan-Noughabi
    [J]. Radiation Oncology, 18
  • [39] Comparison of Three-Dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric-Modulated Arc Therapy In Glioblastoma Multiforme Radiation Therapy With EORTC Target Delineation
    Ibis, Kamuran
    Akbas, Ugur
    Koksal, Canan
    Altun, Musa
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2018, 33 (02): : 65 - 72
  • [40] A dosimetric comparison between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in the treatment of posterior fossa boost in medulloblastoma
    Gupta, Meenu
    Kant, Ravi
    Nautiyal, Vipul
    Bisht, Jyoti
    Raghuvanshi, Shalindra
    Saini, Manju
    Kalra, B. P.
    Ahmad, Mushtaq
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (06) : 1027 - 1031