Design and evaluation of a nanometer aerosol differential mobility analyzer (Nano-DMA)

被引:262
|
作者
Chen, DR
Pui, DYH [1 ]
Hummes, D
Fissan, H
Quant, FR
Sem, GJ
机构
[1] Univ Minnesota, Dept Mech Engn, Particle Technol Lab, Minneapolis, MN 55455 USA
[2] Gerhard Mercator Univ, D-47048 Duisburg, Germany
[3] TSI Inc, St Paul, MN 55164 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0021-8502(97)10018-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A nanometer aerosol differential mobility analyzer, Nano-DMA, has been developed for measuring the size distribution of nanometer aerosols in the particle size range of 3-50 nm. The design is based on a cylindrical configuration and is optimized by means of the numerical model of Chen and Pui (1997, J. Aerosol Sci. 28, 985-1004). Important design features include high particle penetration (low loss) through the Nano-DMA and high sizing resolution. For reducing particle loss in the aerosol transport passage, the aerosol residence time in the Nano-DMA is reduced by shortening the inlet transport passage. An optional feature of high inlet flow (up to 16.5 1pm) is designed in order to further reduce the residence lime between the aerosol inlet and the slit in the classifying region of the Nano-DMA. A new entrance slit is designed to have optimal aerosol and sheath flow matching at a flow ratio of 1:10, and has a wide dynamic flow-ratio range (up to aerosol/sheath flow ratio of 1/70) compared with the TSI-standard DMA design. This slit improvement makes the Nano-DMA suitable for high resolution particle sizing and classification. For reducing the effect of Brownian diffusion broadening on the transfer Function of the Nano-DMA, the collector tube length is shortened to 5.0 cm compared to the TSI-Standard DMA of 44.44 cm and TSI-Short DMA of 11.11 cm. At the design flow condition of 1.5 1pm aerosol (or 16.5 1pm aerosol high inlet flow case) and 15.0 1pm sheath flow rates, the measurable size range is from 3-50 nm. The lower detection limit of 3.0 nm coincides with the lower detection limit of the TSI UCPC (Ultrafine Condensation Particle Counter). The base of the Nano-DMA is completely re-designed to avoid particle loss due to the undesirable electrostatic effect observed by Kousaka et al. (1986, J. Chern. Eng. Japan 19, 401), and to obtain an uniform electric field in the entire classifying region. The overall performance of the Nano-DMA is then evaluated by the numerical model of Chen and Pui (1997, J. Aerosol Sci. 28, 985-1004) before its construction and experimental evaluation. By comparing with the experimental results obtained using the Tandem DMA technique described in Hummes et al. (1996, J. Aerosol Sci. 27, S135-S136; Part. Part. Syst. Charact. 5, 327-332), it is concluded that the Nano-DMA is performing well in the designed size range and its transfer function agrees well with the numerical prediction. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:497 / 509
页数:13
相关论文
共 50 条
  • [11] FACILITATED AEROSOL SIZING USING THE DIFFERENTIAL MOBILITY ANALYZER
    ADACHI, M
    OKUYAMA, K
    KOUSAKA, Y
    MOON, SW
    SEINFELD, JH
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1990, 12 (02) : 225 - 239
  • [12] A Differential Mobility Analyzer (DMA) for Size Selection of Nanoparticles at High Flow Rates
    Hontanon, E.
    Kruis, F. E.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 25 - 37
  • [13] Practical limitations of aerosol separation by a tandem differential mobility analyzer-aerosol particle mass analyzer
    Radney, James G.
    Zangmeister, Christopher D.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (02) : 160 - 172
  • [14] LOSS OF ULTRAFINE AEROSOL-PARTICLES IN DIFFERENTIAL MOBILITY ANALYZER
    KOUSAKA, Y
    OKUYAMA, K
    HAYASHI, K
    [J]. JOURNAL OF AEROSOL SCIENCE, 1984, 15 (03) : 375 - 376
  • [15] Numerical modeling of the performance of differential mobility analyzers for nanometer aerosol measurements
    Chen, DR
    Pui, DYH
    [J]. JOURNAL OF AEROSOL SCIENCE, 1997, 28 (06) : 985 - 1004
  • [16] A cost-effective differential mobility analyzer (cDMA) for multiple DMA column applications
    Mei, Fan
    Fu, Huijing
    Chen, Da-Ren
    [J]. JOURNAL OF AEROSOL SCIENCE, 2011, 42 (07) : 462 - 473
  • [17] Design and optimization of a medium flow differential mobility analyzer (MF-DMA) for classification of high-density particles
    Rosenberger, T.
    Kiesler, D.
    Hontanon, E.
    Fuentes, D.
    Ramiro, E.
    Kruis, F. E.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2019, 53 (10) : 1172 - 1185
  • [18] Experimental comparison of four differential mobility analyzers for nanometer aerosol measurements
    Fissan, H
    Hummes, D
    Stratmann, F
    Buscher, P
    Neumann, S
    Pui, DYH
    Chen, D
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1996, 24 (01) : 1 - 13
  • [19] Two dimensional size-mass distribution function inversion from differential mobility analyzer-aerosol particle mass analyzer (DMA-APM) measurements
    Rawat, Vivek K.
    Buckley, David T.
    Kimoto, Shigeru
    Lee, Myong-Hwa
    Fukushima, Nobuhiko
    Hogan, Christopher J., Jr.
    [J]. JOURNAL OF AEROSOL SCIENCE, 2016, 92 : 70 - 82
  • [20] Performance of Vienna type differential mobility analyzer at 1.2-20 nanometer
    Reischl, GP
    Makela, JM
    Necid, J
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (06) : 651 - 672