Analysis of measurement accuracy of quadrilateral hole using optical inner-diameter-measuring machine

被引:3
|
作者
Liangpanich, E [1 ]
Akiyama, N [1 ]
Yoshida, M [1 ]
Kuwabara, K [1 ]
机构
[1] Nagaoka Univ Technol, Dept Mech Engn, Niigata 9402188, Japan
关键词
quadrilateral hole; gap measurement; optical measurement; spherical aberration;
D O I
10.1117/1.1598435
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We develop a technology for detecting the inner wall (not an "edge portion") of a small hole in machine parts such as a die, a nozzle, and a gauge directly and measuring the inner diameter (usually, the inner diameter is 0.3 to 10.0 mm and the length of hole is 1 to 20 mm). Especially, we discuss theoretically and experimentally the measurement error in a gap larger than 0.3 mm of a quadrilateral hole sample using an optical noncontact measuring machine. By projecting a spot image onto the sample's inside wall and detecting the reflected image with a CCD camera, the position of the inside wall of the sample can be measured. The inner diameter of the sample can be measured from the distance between the positions of each inside wall. Experimental results show that the measurement error of the gap varies with the gap size of the sample. In a comparison with theoretical simulation results, it is verified that the spherical aberrations of the lens in the measuring machine is the cause of this error. With the maximum spherical aberration of the lens at 50 Am, the maximum measurement error of the gap is +1.0 mum for a 0.3 x 0.3-mm square hole, and is -0.30 to -0.35 mum for a quadrilateral hole with a gap larger than 0.6 mm. These theoretical results are in good agreement with the experimental results. The measurement error is always negative when the spherical aberration is assumed to be 0. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
下载
收藏
页码:2568 / 2575
页数:8
相关论文
共 50 条
  • [31] Research on Five Sections Measuring Model in Process Pneumatic Measurement System for Inner Hole Honing
    Ning, Huifeng
    Li, Xiao
    Gong, Jun
    Xu, Hongtao
    EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 1342 - +
  • [32] Research for On-Line Measurement of Optical Fiber Diameter Based on Machine Vision
    Yang, Yuan
    Geng, Tao
    Li, Peng
    Yang, WenLei
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 6497 - 6502
  • [33] Some interpretations and analysis concerning the accuracy of the thin wire diameter measurement
    Serroukh, I
    Bernabeu, E
    FIFTH SYMPOSIUM OPTICS IN INDUSTRY, 2006, 6046
  • [34] Measuring the Diameter Of the Aortic Valve Using the EndoFLIP® Endobimenal Measurement Catheter
    Nolan, David
    O'Dea, John
    Reilly, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B78 - B78
  • [35] Traceability of the primary Nano-flow measurement System: Measuring the local inner diameter of a glass capillary
    Boudaoud, A. W.
    McGraw, J. D.
    Lopez-Leon, T.
    Ogheard, F.
    MEASUREMENT, 2023, 218
  • [36] The accuracy of Video Image Analysis (VIA) and Optical Fibre Diameter Analysis (OFDA) to measure fibre diameter of cashmere
    van Niekerk, WA
    Keva, S
    Roets, M
    Coertze, RJ
    SOUTH AFRICAN JOURNAL OF ANIMAL SCIENCE, 2004, 34 : 143 - 144
  • [37] Volumetric error calibration of a coordinate measuring machine using a hole bar
    Di Giacomo, B.
    Zirondi, R.B.
    Marques, A.
    Informacion Tecnologica, 2003, 14 (01): : 71 - 74
  • [38] Measurement of cashmere yield and mean fibre diameter using the optical fibre diameter analyser
    Peterson, AD
    Gherardi, SG
    AUSTRALIAN JOURNAL OF EXPERIMENTAL AGRICULTURE, 1996, 36 (04): : 429 - 435
  • [39] The measurement and analysis of the noise spectrum of optical machine
    Li, H
    Zhang, YP
    Liu, FL
    Yang, TQ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1939 - 1942
  • [40] Analysis and Compensation of Equivalent Diameter Error of Articulated Arm Coordinate Measuring Machine
    Luo, Zai
    Liu, Hui
    Li, Dong
    Tian, Kun
    MEASUREMENT & CONTROL, 2018, 51 (1-2): : 16 - 26