Analysis of measurement accuracy of quadrilateral hole using optical inner-diameter-measuring machine

被引:3
|
作者
Liangpanich, E [1 ]
Akiyama, N [1 ]
Yoshida, M [1 ]
Kuwabara, K [1 ]
机构
[1] Nagaoka Univ Technol, Dept Mech Engn, Niigata 9402188, Japan
关键词
quadrilateral hole; gap measurement; optical measurement; spherical aberration;
D O I
10.1117/1.1598435
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We develop a technology for detecting the inner wall (not an "edge portion") of a small hole in machine parts such as a die, a nozzle, and a gauge directly and measuring the inner diameter (usually, the inner diameter is 0.3 to 10.0 mm and the length of hole is 1 to 20 mm). Especially, we discuss theoretically and experimentally the measurement error in a gap larger than 0.3 mm of a quadrilateral hole sample using an optical noncontact measuring machine. By projecting a spot image onto the sample's inside wall and detecting the reflected image with a CCD camera, the position of the inside wall of the sample can be measured. The inner diameter of the sample can be measured from the distance between the positions of each inside wall. Experimental results show that the measurement error of the gap varies with the gap size of the sample. In a comparison with theoretical simulation results, it is verified that the spherical aberrations of the lens in the measuring machine is the cause of this error. With the maximum spherical aberration of the lens at 50 Am, the maximum measurement error of the gap is +1.0 mum for a 0.3 x 0.3-mm square hole, and is -0.30 to -0.35 mum for a quadrilateral hole with a gap larger than 0.6 mm. These theoretical results are in good agreement with the experimental results. The measurement error is always negative when the spherical aberration is assumed to be 0. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
下载
收藏
页码:2568 / 2575
页数:8
相关论文
共 50 条
  • [21] Raising the accuracy of the diffraction method of measuring the diameter of thin homogeneous optical fibers
    Veselovskii, A.B.
    Mitrofanov, A.S.
    Poyarkov, V.N.
    Measurement Techniques, 1991, 33 (10) : 992 - 995
  • [22] The impact of using inner-to-inner wall diameter measurement of abdominal aortic aneurysm
    Sensier, Y.
    Akil, Y.
    Khodabakhsh, P.
    Naylor, M.
    Sharpe, R.
    Walker, J.
    Hartshorne, T.
    ULTRASOUND, 2013, 21 (01) : 8 - 11
  • [23] The impact of using inner-to-inner wall diameter measurement of abdominal aortic aneurysm
    Wolstenhulme, Stephen
    ULTRASOUND, 2013, 21 (02) : 105 - 105
  • [24] Research on Non-Contact Optical Measurement Methods for the Dimension of Inner Diameter
    Liu Bo
    Li Xiaogang
    Wang MingXing
    2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 239 - 241
  • [25] Measurement accuracy increase in fiber measuring systems with optical sensors
    Dem'yanenko, P.A.
    Radiotekhnika, 1991, (02): : 83 - 85
  • [26] Deep-hole inner diameter measuring system based on non-contact capacitance sensor
    Yu Y.
    Zhang H.
    Wang Z.
    Chang Y.
    Transactions of Tianjin University, 2010, 16 (6) : 447 - 451
  • [27] Deep-Hole Inner Diameter Measuring System Based on Non-contact Capacitance Sensor
    于永新
    张恒
    王宗超
    常以哲
    Transactions of Tianjin University, 2010, 16 (06) : 447 - 451
  • [28] Deep-Hole Inner Diameter Measuring System Based on Non-contact Capacitance Sensor
    于永新
    张恒
    王宗超
    常以哲
    Transactions of Tianjin University, 2010, (06) : 447 - 451
  • [29] AN ACCURACY ANALYSIS OF SMALL ANGLE MEASUREMENT USING THE OPTICAL VORTEX INTERFEROMETER
    Fraczek, Ewa
    Mroczka, Janusz
    METROLOGY AND MEASUREMENT SYSTEMS, 2009, 16 (02) : 249 - 257
  • [30] Measurement Accuracy Analysis for On-Board Measuring Devices
    Stroganova, E. P.
    Varlamov, O. V.
    2018 SYSTEMS OF SIGNALS GENERATING AND PROCESSING IN THE FIELD OF ON BOARD COMMUNICATIONS, 2018,