One-dimensional x-ray microscope for shock measurements in high-density aluminum plasmas

被引:8
|
作者
Workman, J [1 ]
Tierney, T [1 ]
Evans, S [1 ]
Kyrala, G [1 ]
Benage, J [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1999年 / 70卷 / 01期
关键词
D O I
10.1063/1.1149359
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate experimental measurements of the equation of state for strongly coupled plasmas (Gamma greater than or equal to 1), relevant to astrophysical, geologic and inertial confinement fusion applications, have been extremely difficult. In this pursuit, we have designed a one-dimensional dual-crystal x-ray microscope for making high-resolution measurements of shocks launched by laser pulses in high-density aluminum plasmas. Optical ray-tracing analysis of the design is presented including effects of surface aberrations. The spherically bent mica crystals are arranged at near normal incidence to operate at energies of 1.35 and 4.75 keV using the second and seventh order reflections, respectively. With a magnification of 45X, the microscope's spatial resolution is predicted to be better than 2 mu m when coupled to an x-ray streak camera. The addition of a grazing-incidence optic perpendicular to the imaging direction partially compensates astigmatism. This compensation provides an increase in collection efficiency at the streak camera slit by a factor of similar to 15. (C) 1999 American Institute of Physics.[S0034-6748(99)62401-7].
引用
收藏
页码:613 / 616
页数:4
相关论文
共 50 条
  • [21] X-RAY DIFFRACTION BY SYSTEMS OF LONG MOLECULES AND ONE-DIMENSIONAL X-RAY DIFFRACTION OF CELLULOSE
    KITAYGORODSKY, AI
    TSVANKIN, DY
    ACTA CRYSTALLOGRAPHICA, 1960, 13 (12): : 1142 - 1143
  • [22] Time-resolved x-ray spectra from laser-generated high-density plasmas
    Andiel, U
    Eidmann, K
    Witte, K
    ECLIM 2000: 26TH EUROPEAN CONFERENCE ON LASER INTERACTION WITH MATTER, 2001, 4424 : 496 - 499
  • [23] On characterization of shock propagation and radiative preheating in x-ray driven high-density carbon foils
    Mishra, Gaurav
    Ghosh, Karabi
    PHYSICS OF PLASMAS, 2023, 30 (04)
  • [24] Mixed stitching interferometry with correction from one-dimensional profile measurements for high-precision X-ray mirrors
    Wu, Qiaoyu
    Huang, Qiushi
    Yu, Jun
    Zhu, Yifan
    Gu, Weichen
    Sheng, Pengfeng
    He, Yumei
    Luo, Hongxin
    Zhang, Zhong
    Wang, Zhanshan
    OPTICS EXPRESS, 2023, 31 (10) : 16330 - 16347
  • [25] X-ray diffraction by a one-dimensional paracrystal of limited size
    Mu, XQ
    ACTA CRYSTALLOGRAPHICA SECTION A, 1998, 54 : 606 - 616
  • [26] X-Ray Diffraction by the One-dimensional Superlattice with a Stacking Fault
    Manukyan, H. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2007, 63 : S254 - S255
  • [27] High resolution x-ray diffraction methodology for the structural analysis of one-dimensional nanostructures
    Martinez-Tomas, M. C.
    Montenegro, D. N.
    Sallet, V.
    Munoz-Sanjose, V.
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (01)
  • [28] The benefits of one-dimensional detectors for high-pressure powder X-ray diffraction
    Fisch, Martin
    Lanza, Arianna
    Macchi, Piero
    Casati, Nicola
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2015, 48 : 1956 - 1963
  • [29] Image plates as one-dimensional detectors in high-resolution X-ray diffraction
    Kinne, A
    Thoms, M
    Ress, HR
    Gerhard, T
    Ehinger, M
    Faschinger, W
    Landwehr, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 : 446 - 452
  • [30] High-density arrays of x-ray microcalorimeters for Constellation-X
    Kilbourne, Caroline A.
    Bandler, Simon R.
    Brown, Ari D.
    Chervenak, James A.
    Figueroa-Feliciano, Enectali
    Finkbeiner, Fred M.
    Iyomoto, Naoko
    Kelley, Richard L.
    Porter, F. Scott
    Saab, Tarek
    Sadleir, John
    White, Jennifer
    SPACE TELESCOPES AND INSTRUMENTATION II: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2006, 6266