Numerical investigation for the room with displacement ventilation and cooling ceiling system

被引:0
|
作者
Na, YL [1 ]
Tu, GB [1 ]
Yu, SB [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
If the vertical temperature difference in room caused by thermal delamination of displacement ventilation is too high, people may feel uncomfortable. To increase the cooling capacity of air-conditioning systems, the combination of displacement ventilation and cooling ceiling can not only improve the indoor air quality, enhance the thermal comfort but also make energy saving. In this paper, based on the model of CFD, a numerical simulation of the temperature field, indoor airflow field and thermal comfort in room with and without a cooling ceiling was processed by using a finite-volume method, and the result of the simulation was analyzed to give some pieces of advice to engineers or designers.
引用
收藏
页码:591 / 594
页数:4
相关论文
共 50 条
  • [1] Numerical investigation of transient buoyant flow in a room with a displacement ventilation and chilled ceiling system
    Rees, SJ
    McGuirk, JJ
    Haves, P
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (16) : 3067 - 3080
  • [2] NUMERICAL INVESTIGATION OF OFFICE ROOM VENTILATION BY ADOPTING DISPLACEMENT VENTILATION AND CHILLED CEILING SYSTEM IN A HOT AND DRY CLIMATE
    Shbeeb, Ali A.
    Mahdi, Ala'a A.
    Hussein, Ahmed K.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 17 (04): : 2958 - 2982
  • [3] Investigation of the displacement effect of a diffuse ceiling ventilation system
    Petersen, Steffen
    Christensen, Niels Uhre
    Heinsen, Caroline
    Hansen, Anne Sophie
    ENERGY AND BUILDINGS, 2014, 85 : 265 - 274
  • [4] A method to avoid condensation and downdraft in displacement ventilation and cooling ceiling system
    Wang, J
    Long, W
    Cai, H
    Dong, T
    Wang, Q
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1106 - 1110
  • [5] Chilled ceiling and displacement ventilation system: Laboratory study with high cooling load
    Schiavon, Stefano
    Bauman, Fred S.
    Tully, Brad
    Rimmer, Julian
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 944 - 956
  • [6] Numerical investigation of airborne transmission in low-ceiling rooms under displacement ventilation
    Wang, Changchang
    Hong, Jiarong
    PHYSICS OF FLUIDS, 2023, 35 (02)
  • [7] Study on Indoor Air Quality of Ceiling Radiant Cooling Panel System Integrated with Displacement Ventilation
    Du, Jing
    Li, Nianping
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 497 - 505
  • [8] Air Distribution and Ventilation Effectiveness in a Room with Floor/Ceiling Heating and Mixing/Displacement Ventilation
    Wu, Xiaozhou
    Fang, Lei
    Olesen, Bjarne W.
    Zhao, Jianing
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 59 - 67
  • [9] Room air stratification in combined chilled ceiling and displacement ventilation systems
    Schiavon, Stefano
    Bauman, Fred
    Tully, Brad
    Rimmer, Julian
    HVAC&R RESEARCH, 2012, 18 (1-2): : 147 - 159
  • [10] Room cooling load and ceiling cooling
    Galaso, I
    Curko, T
    Zvizdic, D
    ENERGY AND THE ENVIRONMENT, 1999, : 545 - 547