IH-DTL design with modified KONUS beam dynamics for a synchrotron-based proton therapy system

被引:8
|
作者
Tang, Ruo [1 ,2 ,3 ,4 ]
Xing, Qingzi [1 ,2 ,3 ]
Zheng, Shuxin [1 ,2 ,3 ]
Guan, Xialing [1 ,2 ,3 ]
Tang, Chuanxiang [1 ,2 ,3 ]
Wang, Xuewu [1 ,2 ,3 ]
Shi, Jinshui [4 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, CN-100084 Beijing, Peoples R China
[2] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, CN-100084 Beijing, Peoples R China
[3] Tsinghua Univ, Lab Adv Radiat Sources & Applicat, Beijing 100084, Peoples R China
[4] CAEP, Inst Fluid Phys, POB 919-106, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
IH-DTL; KONUS; Proton therapy; INJECTOR; LINAC;
D O I
10.1016/j.nima.2018.10.125
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A modified Kombinierte Null Grad Struktur (KONUS) beam dynamics for inter-digital H-mode (IH) drift tube linac (DTL) is proposed in this study. This modified KONUS beam dynamics, which is aperiodic and is suitable for a short (<1 m) DTL design, is applied to a dedicated 325 MHz IH-DTL design at Tsinghua University. The IH-DTL, which is utilized in the injector of a synchrotron-based proton therapy system, is divided into three sections, namely, rebunching (-80 degrees), 0 degrees acceleration, and debunching (10 degrees). It is slightly different from the conventional KONUS cavity, and no focusing magnets exist in the cavity to reduce the cost of fabrication. The presence of 21 gaps in the cavity can accelerate a 15 mA proton beam from 3 MeV to 7 MeV. The cavity is tapered to adjust the gap voltage distribution, and the inner diameter varies from 196.8 mm to 232.6 mm. A cavity length of 1 m has a theoretical power consumption of 151 kW, whereas the maximum surface electric field is 40 MV/m (2.3 Kp). A new design process, which is similar to alternating-phase focusing method, is proposed. Details of the design method and results are presented in this study.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 50 条
  • [31] Achievability and Optimization of Synchrotron-Based Respiratory Gated Spot Scanning Proton Beam Delivery
    Tsunashima, Y.
    Sahoo, N.
    Sakae, T.
    Poenisch, F.
    Umezawa, M.
    Briere, T.
    Zhu, X.
    Mohan, R.
    Dong, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3795 - 3795
  • [32] Evaluation of the Mini-ridge Filter's Impact on the Generation of Secondary Radiation in Synchrotron-based Proton Beam Therapy
    Shimo, Takahiro
    Shiba, Shintaro
    Watanabe, Hiroyuki
    Yamanaka, Masashi
    Matsumoto, Kazuki
    Yamano, Akihiro
    Tokuuye, Kohichi
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 14 - 19
  • [33] Monte Carlo framework for commissioning a synchrotron-based discrete spot scanning proton beam system and treatment plan verification
    Moskvin, Vadim P.
    Faught, Austin
    Pirlepesov, Fakhriddin
    Zhao, Li
    Hua, Chia-Ho
    Merchant, Thomas E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
  • [34] Investigation of dosimetric effect of beam current fluctuations in synchrotron-based proton PBS continuous scanning
    Liu, Chunbo
    Furutani, Keith M.
    Shen, Jiajian
    Tseung, Hok Wan Chan
    Tan, Hong Qi
    Li, Heng
    Whitaker, Thomas J.
    Beltran, Chris J.
    Liang, Xiaoying
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (13):
  • [35] Beam monitor calibration of a synchrotron-based scanned light-ion beam delivery system
    Osorio, Jhonnatan
    Dreindl, Ralf
    Grevillot, Loic
    Letellier, Virgile
    Kuess, Peter
    Carlino, Antonio
    Elia, Alessio
    Stock, Markus
    Vatnitsky, Stanislav
    Palmans, Hugo
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 154 - 165
  • [36] Optimization and evaluation of multiple gating beam delivery in a synchrotron-based proton beam scanning system using a real-time imaging technique
    Yamada, Takahiro
    Miyamoto, Naoki
    Matsuura, Taeko
    Takao, Seishin
    Fujii, Yusuke
    Matsuzaki, Yuka
    Koyano, Hidenori
    Umezawa, Masumi
    Nihongi, Hideaki
    Shimizu, Shinichi
    Shirato, Hiroki
    Umegaki, Kikuo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (07): : 932 - 937
  • [37] The Design and Initial Testing of the Beam Phase and Energy Measurement System for DTL in the Proton Accelerator of CSNS
    Zhao, Lei
    Liu, Shubin
    Tang, Shaochun
    An, Qi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 533 - 538
  • [38] Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data
    Yoshimura, Takaaki
    Shimizu, Shinichi
    Hashimoto, Takayuki
    Nishioka, Kentaro
    Katoh, Norio
    Taguchi, Hiroshi
    Yasuda, Koichi
    Matsuura, Taeko
    Takao, Seishin
    Tamura, Masaya
    Tanaka, Sodai
    Ito, Yoichi M.
    Matsuo, Yuto
    Tamura, Hiroshi
    Horita, Kenji
    Umegaki, Kikuo
    Shirato, Hiroki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 10 - 19
  • [39] The Design and Initial Testing of the Beam Phase and Energy Measurement System for DTL in the Proton Accelerator of CSNS
    Zhao, Lei
    Liu, Shubin
    Tang, Shaochun
    An, Qi
    2009 16TH IEEE-NPSS REAL TIME CONFERENCE, 2009, : 70 - 75
  • [40] Investigating the biochemical response of proton minibeam radiation therapy by means of synchrotron-based infrared microspectroscopy
    Gonzalez-Vegas, Roberto
    Yousef, Ibraheem
    Seksek, Olivier
    Ortiz, Ramon
    Bertho, Annaig
    Juchaux, Marjorie
    Nauraye, Catherine
    De Marzi, Ludovic
    Patriarca, Annalisa
    Prezado, Yolanda
    Martinez-Rovira, Immaculada
    SCIENTIFIC REPORTS, 2024, 14 (01):