Protocol for X-ray dosimetry in radiobiology

被引:18
|
作者
Zoetelief, J
Broerse, JJ
Davies, RW
Octave-Prignot, M
Rezvani, M
Vergara, JCS
Toni, MP
机构
[1] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
[2] Leiden Univ, Med Ctr, NL-2300 RC Leiden, Netherlands
[3] Nycomed Amersham Plc, Amersham HP7 9NA, England
[4] Clin Univ St Luc, B-1200 Brussels, Belgium
[5] Univ Oxford, Churchill Hosp, Res Inst, Oxford OX3 7LJ, England
[6] CIEMAT, E-28040 Madrid, Spain
[7] ENEA CR Casaccia, Ist Nazl Metrol Radiaz Ionizzanti, I-0100 Rome, Italy
关键词
D O I
10.1080/09553000110050605
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To harmonize X-ray dosimetry in radiobiology to allow a direct comparison of radiobiological studies performed at institutes cooperation within the framework of the European Late Effects Project Group (EULEP). Materials and methods: The 1985 EULEP protocol for X-ray dosimetry and exposure arrangements employed for studies of late somatic effects in mammals required serious revision, e.g. due to the replacement of calibration of dosemeters in terms of exposure by calibration in terms of air kerma free-in-air. An action group established by EULEP and the European Radiation Dosimetry Group (EURADOS) updated the 1985 protocol. Results: The new EULEP EURADOS protocol for X-ray dosimetry in radiobiology including the code of practice for irradiation of small animals and related dosimetry. The present protocol includes the changes in calibration procedures and dosimetric concepts for irradiation with medium energy X-rays since 1985. Accuracy and precision are replaced by the concept of combined (standard) uncertainty. The revised supplements provide more detailed background information. New appendices contain definitions of general terms used for measurements and mathematical expressions of the relative variances. Conclusion: Adherence to the present protocol will result in improved dosimetry and facilitates the comparison of results of radiobiological experiments obtained at different institutes.
引用
收藏
页码:817 / 835
页数:19
相关论文
共 50 条
  • [21] Superficial and orthovoltage x-ray beam dosimetry
    Podgorsak, EB
    Gosselin, M
    Evans, MDC
    MEDICAL PHYSICS, 1998, 25 (07) : 1206 - 1211
  • [22] Dosimetry for a monochromatic X-ray source, the CXS
    Norman, A
    Iwamoto, K
    Solberg, T
    Landahl, E
    Luhmann, N
    MEDICAL PHYSICS, 2002, 29 (06) : 1249 - 1249
  • [23] 4 MEV X-RAY FILM DOSIMETRY
    JACOBSON, A
    RADIOLOGY, 1972, 103 (03) : 703 - &
  • [24] Fluorescent Nanogel Sensors for X-ray Dosimetry
    Jiang, Li
    Li, Wenxiang
    Nie, Jing
    Wang, Rensheng
    Chen, Xinjian
    Fan, Wenhui
    Hu, Liang
    ACS SENSORS, 2021, 6 (04) : 1643 - 1648
  • [26] Advances in kilovoltage x-ray beam dosimetry
    Hill, Robin
    Healy, Brendan
    Holloway, Lois
    Kuncic, Zdenka
    Thwaites, David
    Baldock, Clive
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (06): : R183 - R231
  • [27] MOSFET dosimetry of an X-ray microbeam.
    Rosenfeld, AB
    Kaplan, GI
    Kron, T
    Allen, BJ
    Dilmanian, A
    Orion, I
    Ren, B
    Lerch, MLF
    Holmes-Siedle, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1774 - 1780
  • [28] PROTOCOL FOR DOSIMETRY OF X-RAY AND GAMMA-RAY BEAMS WITH MAXIMUM ENERGIES BETWEEN 0.6 AND 50 MEV
    不详
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 379 - &
  • [29] Visualized X-ray Dosimetry for Multienvironment Applications
    Lu, Lan
    Peng, Songcheng
    Zhao, Lei
    Zhang, Meiguang
    Xiao, Jianqiang
    Wen, Hongyu
    Zhang, Peng
    Yakovlev, Alexey Nikolaevich
    Qiu, Jianbei
    Yu, Xue
    Wang, Ting
    Xu, Xuhui
    NANO LETTERS, 2023, 23 (18) : 8753 - 8760
  • [30] INVESTIGATION OF A VACUUM CHAMBER FOR X-RAY DOSIMETRY
    BEKTURGA.K
    GUMANSKI.GA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (01): : 71 - &