Visualized X-ray Dosimetry for Multienvironment Applications

被引:12
|
作者
Lu, Lan [1 ]
Peng, Songcheng [1 ]
Zhao, Lei [2 ]
Zhang, Meiguang [2 ]
Xiao, Jianqiang [1 ]
Wen, Hongyu [1 ]
Zhang, Peng [1 ]
Yakovlev, Alexey Nikolaevich [3 ]
Qiu, Jianbei [1 ]
Yu, Xue [4 ]
Wang, Ting [5 ]
Xu, Xuhui [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Mat Sci & Engn, Kunming 650093, Yunnan, Peoples R China
[2] Baoji Univ Arts & Sci, Coll Phys & Optoelect Technol, Collaborat Innovat Ctr Rare Earth Funct Mat & Dev, Baoji 721016, Peoples R China
[3] TF Gorbachev Kuzbass State Tech Univ, Kemerovo 650000, Russia
[4] Chengdu Univ, Inst Adv Mat Deformat & Damage Multiscale, Sch Mech Engn, Chengdu 610106, Peoples R China
[5] Chengdu Univ Technol, Sch Mat & Chem & Chem Engn, Chengdu 610059, Sichuan, Peoples R China
关键词
X-ray dose detection; multienvironment; color-tunable; cross-relaxation; LUMINESCENCE;
D O I
10.1021/acs.nanolett.3c02826
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
X-ray dose detection plays a critical role in various scientific fields, including chemistry, materials, and medicine. However, the current materials used for this purpose face challenges in both immediate and delayed radiation detections. Here, we present a visual X-ray dosimetry method for multienvironment applications, utilizing NaLuF4 nanocrystals (NCs) that undergo a color change from green to red upon X-ray irradiation. By adjustment of the concentrations of Ho3+, the emission color of the NCs can be tuned thanks to the cross-relaxation effects. Furthermore, X-ray irradiation induces generation of trapping centers in NaLuF4:Ho3+ NCs, endowing the generation of mechanoluminescence (ML) behavior upon mechanical stimulation after X-ray irradiation ceases. The ML intensity shows a linear correlation with the X-ray dose, facilitating the detection of delayed radiation. This breakthrough facilitates X-ray dose inspection in flaw detection, nuclear medicine, customs, and civil protection, thereby enhancing opportunities for radiation monitoring and control.
引用
收藏
页码:8753 / 8760
页数:8
相关论文
共 50 条
  • [1] Suitability of Synthetic Diamond Films for X-ray Dosimetry Applications
    Lansley, S. P.
    Betzel, G. T.
    Baluti, F.
    Lydon, J.
    Reinisch, L.
    COMMAD: 2008 CONFERENCE ON OPTOELECTRONIC AND MICROELECTRONIC MATERIALS & DEVICES, 2008, : 34 - +
  • [2] A NEW CIRCUIT WITH SPECIAL APPLICATIONS IN GAMMA-RAY AND X-RAY DOSIMETRY
    KEMP, LAW
    BRITISH JOURNAL OF RADIOLOGY, 1945, 18 (208): : 107 - 112
  • [3] Characterization of X-Ray Acoustic Computed Tomography for Applications in Radiotherapy Dosimetry
    Hickling, Susannah
    Hobson, Maritza
    El Naqa, Issam
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (04) : 337 - 344
  • [4] DOSIMETRY AT X-RAY EXAMINATIONS OF SCOLIOSIS
    HALLEN, S
    MARTLING, K
    MATTSSON, S
    RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 49 - 54
  • [5] MOSFET dosimetry of an X-ray microbeam
    Rosenfeld, A.B.
    Kaplan, G.I.
    Kron, T.
    Allen, B.J.
    Dilmanian, A.
    Orion, I.
    Ren, B.
    Lerch, M.L.F.
    Holmes-Siedle, A.
    IEEE Transactions on Nuclear Science, 1999, 46 (6 I): : 1774 - 1780
  • [6] Protocol for X-ray dosimetry in radiobiology
    Zoetelief, J
    Broerse, JJ
    Davies, RW
    Octave-Prignot, M
    Rezvani, M
    Vergara, JCS
    Toni, MP
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2001, 77 (07) : 817 - 835
  • [7] DOSIMETRY FOR ASYMMETRIC X-RAY FIELDS
    KWA, W
    KORNELSEN, RO
    HARRISON, RW
    ELKHATIB, E
    MEDICAL PHYSICS, 1994, 21 (10) : 1599 - 1604
  • [8] DOSIMETRY OF ASYMMETRIC X-RAY COLLIMATORS
    KHAN, FM
    GERBI, BJ
    DEIBEL, FC
    MEDICAL PHYSICS, 1986, 13 (06) : 936 - 941
  • [9] PHOTOGRAPHIC X-RAY AND GAMMA-RAY DOSIMETRY
    EHRLICH, M
    FITCH, SH
    NUCLEONICS, 1951, 9 (03): : 5 - 17
  • [10] BASIS OF X-RAY AND GAMMA-RAY DOSIMETRY
    DAY, MJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (01): : 153 - &