Visualized X-ray Dosimetry for Multienvironment Applications

被引:12
|
作者
Lu, Lan [1 ]
Peng, Songcheng [1 ]
Zhao, Lei [2 ]
Zhang, Meiguang [2 ]
Xiao, Jianqiang [1 ]
Wen, Hongyu [1 ]
Zhang, Peng [1 ]
Yakovlev, Alexey Nikolaevich [3 ]
Qiu, Jianbei [1 ]
Yu, Xue [4 ]
Wang, Ting [5 ]
Xu, Xuhui [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Mat Sci & Engn, Kunming 650093, Yunnan, Peoples R China
[2] Baoji Univ Arts & Sci, Coll Phys & Optoelect Technol, Collaborat Innovat Ctr Rare Earth Funct Mat & Dev, Baoji 721016, Peoples R China
[3] TF Gorbachev Kuzbass State Tech Univ, Kemerovo 650000, Russia
[4] Chengdu Univ, Inst Adv Mat Deformat & Damage Multiscale, Sch Mech Engn, Chengdu 610106, Peoples R China
[5] Chengdu Univ Technol, Sch Mat & Chem & Chem Engn, Chengdu 610059, Sichuan, Peoples R China
关键词
X-ray dose detection; multienvironment; color-tunable; cross-relaxation; LUMINESCENCE;
D O I
10.1021/acs.nanolett.3c02826
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
X-ray dose detection plays a critical role in various scientific fields, including chemistry, materials, and medicine. However, the current materials used for this purpose face challenges in both immediate and delayed radiation detections. Here, we present a visual X-ray dosimetry method for multienvironment applications, utilizing NaLuF4 nanocrystals (NCs) that undergo a color change from green to red upon X-ray irradiation. By adjustment of the concentrations of Ho3+, the emission color of the NCs can be tuned thanks to the cross-relaxation effects. Furthermore, X-ray irradiation induces generation of trapping centers in NaLuF4:Ho3+ NCs, endowing the generation of mechanoluminescence (ML) behavior upon mechanical stimulation after X-ray irradiation ceases. The ML intensity shows a linear correlation with the X-ray dose, facilitating the detection of delayed radiation. This breakthrough facilitates X-ray dose inspection in flaw detection, nuclear medicine, customs, and civil protection, thereby enhancing opportunities for radiation monitoring and control.
引用
收藏
页码:8753 / 8760
页数:8
相关论文
共 50 条
  • [11] Experimental evaluation of x-ray acoustic computed tomography for radiotherapy dosimetry applications
    Hickling, Susannah
    Lei, Hao
    Hobson, Maritza
    Leger, Pierre
    Wang, Xueding
    El Naqa, Issam
    MEDICAL PHYSICS, 2017, 44 (02) : 608 - 617
  • [12] STRESS-FRACTURES VISUALIZED VIA X-RAY
    DIHLMANN, W
    AKTUELLE RHEUMATOLOGIE, 1995, 20 (02) : 69 - 71
  • [13] Dosimetry for a monochromatic X-ray source, the CXS
    Norman, A
    Iwamoto, K
    Solberg, T
    Landahl, E
    Luhmann, N
    MEDICAL PHYSICS, 2002, 29 (06) : 1249 - 1249
  • [14] Superficial and orthovoltage x-ray beam dosimetry
    Podgorsak, EB
    Gosselin, M
    Evans, MDC
    MEDICAL PHYSICS, 1998, 25 (07) : 1206 - 1211
  • [15] Fluorescent Nanogel Sensors for X-ray Dosimetry
    Jiang, Li
    Li, Wenxiang
    Nie, Jing
    Wang, Rensheng
    Chen, Xinjian
    Fan, Wenhui
    Hu, Liang
    ACS SENSORS, 2021, 6 (04) : 1643 - 1648
  • [16] 4 MEV X-RAY FILM DOSIMETRY
    JACOBSON, A
    RADIOLOGY, 1972, 103 (03) : 703 - &
  • [18] Advances in kilovoltage x-ray beam dosimetry
    Hill, Robin
    Healy, Brendan
    Holloway, Lois
    Kuncic, Zdenka
    Thwaites, David
    Baldock, Clive
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (06): : R183 - R231
  • [19] MOSFET dosimetry of an X-ray microbeam.
    Rosenfeld, AB
    Kaplan, GI
    Kron, T
    Allen, BJ
    Dilmanian, A
    Orion, I
    Ren, B
    Lerch, MLF
    Holmes-Siedle, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1774 - 1780
  • [20] INVESTIGATION OF A VACUUM CHAMBER FOR X-RAY DOSIMETRY
    BEKTURGA.K
    GUMANSKI.GA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (01): : 71 - &