Effects of steady state free precession parameters on cardiac mass, function, and volumes

被引:6
|
作者
Hogan, Maureen C. [1 ]
Petersen, Steffen E. [1 ]
Hudsmith, Lucy E. [1 ]
Francis, Jane M. [1 ]
Neubauer, Stefan [1 ]
Robson, Matthew D. [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Ctr Clin Magnet Resonance Res, Dept Cardiovasc Med, Oxford OX3 9DU, England
来源
基金
英国惠康基金; 英国医学研究理事会;
关键词
interslice gap; magnetic resonance imaging; slice thickness; temporal resolution; ventricular function;
D O I
10.1007/s10554-006-9191-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose We aimed to investigate comparability of LV volumes, function, and mass acquired with three steady-state free precession (SSFP) pulse sequences, simulating typical vendor and protocol specific differences in data acquisition. Methods Twenty-one healthy subjects (11 male and 10 female; age range 23-49) underwent cardiac magnetic resonance (CMR) imaging at 1.5 Tesla (T). A complete stack of short-axis views covering the entire left ventricle (LV) were acquired for each of the three SSFP sequences, differing in the interslice gap and slice thickness (7 mm with no gap (7/0 mm); 7 mm with a 3 mm gap (7/3 mm) and 6 mm with a 4 mm gap (6/4 mm)) with slight variations in acquisition parameters. For each sequence, the LV volumes, function, and mass were determined. Intra- and inter-observer variability and inter-study reproducibility were assessed for all protocols. Results All LV volumes, function and mass parameters were similar for the three SSFP sequences (P > 0.05 for all). The LV ejection fraction for the 7/3 mm sequence was 67.2 +/- 6.0, 67.4 +/- 5.3 for the 7/0 mm sequence, and the 6/4 mm sequence was 69.2 +/- 5.7. The LV mass ranged from 119.8 +/- 32.4 for the 7/3 mm sequence to 122.2 +/- 34.0 for the 7/0 mm sequence. Variabilities were low with no difference in variability between the sequences. Conclusion The three SSFP pulse sequence techniques resulted in similar LV volume, function, and mass measurements with no difference in observer and interstudy variabilities. This may allow application and transfer of LV volume studies and databases based on different imaging parameters, at different CMR sites, with a given post-processing method. Future multi-centre studies may now be in a position to consider multi-vendor study designs for LV volume studies.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 50 条
  • [31] Starter sequence for steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 919 - 929
  • [32] Normal values for paediatric atrial volumes assessed by steady-state free-precession cardiovascular magnetic resonance
    Voges, I.
    Hinz, S.
    Caliebe, A.
    Gracioli, S. Boroni
    Wage, R.
    Gabbert, D.
    Uebing, A.
    Krupickova, S.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1601 - 1601
  • [33] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW LETTERS, 1958, 1 (11) : 429 - 430
  • [34] Linear combination steady-state free precession MRI
    Vasanawala, SS
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (01) : 82 - 90
  • [36] Determining Microvascular Obstruction and Infarct Size with Steady-State Free Precession Imaging Cardiac MRI
    Wuest, Wolfgang
    Lell, Michael
    May, Matthias
    Scharf, Michael
    Schlundt, Christian
    Achenbach, Stephan
    Uder, Michael
    Schmid, Axel
    PLOS ONE, 2015, 10 (03):
  • [37] Free-Breathing Steady-State Free Precession Cine Cardiac Magnetic Resonance with Respiratory Navigator Gating
    Moghari, Mehdi H.
    Komarlu, Rukmini
    Annese, David
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1555 - 1561
  • [38] Quantification of the relationship between two cardiac magnetic resonance techniques: fast gradient echo and steady-state free precession for determination of left atrial volumes
    Filip Zemrak
    Pierre-Jean Pintard
    Elzbieta H Chamera
    Saidi A Mohiddin
    Saman Nazarian
    Joao A Lima
    Steffen E Petersen
    David Bluemke
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [39] Cardiac CINE imaging with IDEAL water-fat separation and steady-state free precession
    Reeder, SB
    Markl, M
    Yu, HZ
    Hellinger, JC
    Herfkens, RJ
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 44 - 52
  • [40] Quantification of vendor-specific relationships between fast gradient echo and steady-state free precession cine MRI for determination of myocardial mass and volumes
    Andrew S Chi
    W Craig Johnson
    Elzbieta Chamera
    John Eng
    Joan Bathon
    Chia-Ying Liu
    Joao AC Lima
    David A Bluemke
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)