Effects of steady state free precession parameters on cardiac mass, function, and volumes

被引:6
|
作者
Hogan, Maureen C. [1 ]
Petersen, Steffen E. [1 ]
Hudsmith, Lucy E. [1 ]
Francis, Jane M. [1 ]
Neubauer, Stefan [1 ]
Robson, Matthew D. [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Ctr Clin Magnet Resonance Res, Dept Cardiovasc Med, Oxford OX3 9DU, England
来源
基金
英国惠康基金; 英国医学研究理事会;
关键词
interslice gap; magnetic resonance imaging; slice thickness; temporal resolution; ventricular function;
D O I
10.1007/s10554-006-9191-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose We aimed to investigate comparability of LV volumes, function, and mass acquired with three steady-state free precession (SSFP) pulse sequences, simulating typical vendor and protocol specific differences in data acquisition. Methods Twenty-one healthy subjects (11 male and 10 female; age range 23-49) underwent cardiac magnetic resonance (CMR) imaging at 1.5 Tesla (T). A complete stack of short-axis views covering the entire left ventricle (LV) were acquired for each of the three SSFP sequences, differing in the interslice gap and slice thickness (7 mm with no gap (7/0 mm); 7 mm with a 3 mm gap (7/3 mm) and 6 mm with a 4 mm gap (6/4 mm)) with slight variations in acquisition parameters. For each sequence, the LV volumes, function, and mass were determined. Intra- and inter-observer variability and inter-study reproducibility were assessed for all protocols. Results All LV volumes, function and mass parameters were similar for the three SSFP sequences (P > 0.05 for all). The LV ejection fraction for the 7/3 mm sequence was 67.2 +/- 6.0, 67.4 +/- 5.3 for the 7/0 mm sequence, and the 6/4 mm sequence was 69.2 +/- 5.7. The LV mass ranged from 119.8 +/- 32.4 for the 7/3 mm sequence to 122.2 +/- 34.0 for the 7/0 mm sequence. Variabilities were low with no difference in variability between the sequences. Conclusion The three SSFP pulse sequence techniques resulted in similar LV volume, function, and mass measurements with no difference in observer and interstudy variabilities. This may allow application and transfer of LV volume studies and databases based on different imaging parameters, at different CMR sites, with a given post-processing method. Future multi-centre studies may now be in a position to consider multi-vendor study designs for LV volume studies.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 50 条
  • [21] Diffusion Imaging with Balanced Steady State Free Precession
    Cheung, Matthew M.
    Wu, Ed X.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 90 - 93
  • [22] Fundamentals of balanced steady state free precession MRI
    Bieri, Oliver
    Scheffler, Klaus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 2 - 11
  • [23] Evaluation of steady state free precession imaging of the pancreas
    Herborn, CU
    Vogt, FM
    Lauenstein, TC
    Goyen, M
    Debatin, JF
    Ruehm, SG
    EUROPEAN RADIOLOGY, 2005, 15 (08) : 1629 - 1633
  • [24] Echo-dephased steady state free precession
    Sunil Patil
    Oliver Bieri
    Klaus Scheffler
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2009, 22 : 277 - 285
  • [26] Alternating repetition time balanced steady state free precession
    Leupold, J
    Hennig, J
    Scheffler, K
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 557 - 565
  • [27] Quantitative diffusion imaging with steady-state free precession
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 428 - 433
  • [28] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [29] MR angiography using steady-state free precession
    Foo, TKF
    Ho, VB
    Marcos, HB
    Hood, MN
    Choyke, PL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 699 - 706
  • [30] Understanding steady-state free precession: A geometric perspective
    Dharmakumar, R
    Wright, GA
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2005, 26A (01) : 1 - 10