Effects of steady state free precession parameters on cardiac mass, function, and volumes

被引:6
|
作者
Hogan, Maureen C. [1 ]
Petersen, Steffen E. [1 ]
Hudsmith, Lucy E. [1 ]
Francis, Jane M. [1 ]
Neubauer, Stefan [1 ]
Robson, Matthew D. [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Ctr Clin Magnet Resonance Res, Dept Cardiovasc Med, Oxford OX3 9DU, England
来源
基金
英国惠康基金; 英国医学研究理事会;
关键词
interslice gap; magnetic resonance imaging; slice thickness; temporal resolution; ventricular function;
D O I
10.1007/s10554-006-9191-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose We aimed to investigate comparability of LV volumes, function, and mass acquired with three steady-state free precession (SSFP) pulse sequences, simulating typical vendor and protocol specific differences in data acquisition. Methods Twenty-one healthy subjects (11 male and 10 female; age range 23-49) underwent cardiac magnetic resonance (CMR) imaging at 1.5 Tesla (T). A complete stack of short-axis views covering the entire left ventricle (LV) were acquired for each of the three SSFP sequences, differing in the interslice gap and slice thickness (7 mm with no gap (7/0 mm); 7 mm with a 3 mm gap (7/3 mm) and 6 mm with a 4 mm gap (6/4 mm)) with slight variations in acquisition parameters. For each sequence, the LV volumes, function, and mass were determined. Intra- and inter-observer variability and inter-study reproducibility were assessed for all protocols. Results All LV volumes, function and mass parameters were similar for the three SSFP sequences (P > 0.05 for all). The LV ejection fraction for the 7/3 mm sequence was 67.2 +/- 6.0, 67.4 +/- 5.3 for the 7/0 mm sequence, and the 6/4 mm sequence was 69.2 +/- 5.7. The LV mass ranged from 119.8 +/- 32.4 for the 7/3 mm sequence to 122.2 +/- 34.0 for the 7/0 mm sequence. Variabilities were low with no difference in variability between the sequences. Conclusion The three SSFP pulse sequence techniques resulted in similar LV volume, function, and mass measurements with no difference in observer and interstudy variabilities. This may allow application and transfer of LV volume studies and databases based on different imaging parameters, at different CMR sites, with a given post-processing method. Future multi-centre studies may now be in a position to consider multi-vendor study designs for LV volume studies.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 50 条
  • [1] Effects of steady state free precession parameters on cardiac mass, function, and volumes
    Maureen C. Hogan
    Steffen E. Petersen
    Lucy E. Hudsmith
    Jane M. Francis
    Stefan Neubauer
    Matthew D. Robson
    The International Journal of Cardiovascular Imaging, 2007, 23 : 583 - 589
  • [2] Cardiac cine MRI: Quantification of the relationship between fast gradient echo and steady-state free precession for determination of myocardial mass and volumes
    Malayeri, Ashkan Akhavan
    Johnson, W. Craig
    Macedo, Robson
    Bathon, Joan
    Lima, Joao A. C.
    Bluemke, David A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 60 - 66
  • [3] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473
  • [4] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903
  • [5] Superbalanced steady state free precession
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1346 - 1354
  • [6] High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession
    Peters, DC
    Ennis, DB
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 82 - 88
  • [7] Reference left atrial dimensions and volumes by steady state free precession cardiovascular magnetic resonance
    Alicia M Maceira
    Juan Cosín-Sales
    Michael Roughton
    Sanjay K Prasad
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 12
  • [8] Reference left atrial dimensions and volumes by steady state free precession cardiovascular magnetic resonance
    Maceira, Alicia M.
    Cosin-Sales, Juan
    Roughton, Michael
    Prasad, Sanjay K.
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [9] Morphing steady-state free precession
    Bieri, O.
    Patil, S.
    Quick, H. H.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1242 - 1248
  • [10] Balanced Steady State Free Precession fMRI
    Lee, Jin Hyung
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2010, 20 (01) : 23 - 30