Development of an Integrated C-Arm Interventional Imaging System With a Strip Photon Counting Detector and a Flat Panel Detector

被引:1
|
作者
Ji, Xu [1 ]
Feng, Mang [1 ]
Treb, Kevin [1 ]
Zhang, Ran [1 ]
Schafer, Sebastian [2 ]
Li, Ke [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Siemens Healthineers, Adv Therapies, D-91301 Forchheim, Germany
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
关键词
Photon counting detector; photon counting CT; image guided intervention; C-arm x-ray systems; CONE-BEAM CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; PROJECTION; QUALITY; RECONSTRUCTION; ALGORITHM; ABLATION; GUIDANCE; MOBILE;
D O I
10.1109/TMI.2021.3095419
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Modern interventional x-ray systems are often equipped with flat-panel detector-based cone-beam CT (FPD-CBCT) to provide tomographic, volumetric, and high spatial resolution imaging of interventional devices, iodinated vessels, and other objects. The purpose of this work was to bring an interchangeable strip photon-counting detector (PCD) to C-arm systems to supplement (instead of retiring) the existing FPD-CBCT with a high quality, spectral, and affordable PCD-CT imaging option. With minimal modification to the existing C-arm, a 51 x 0.6 cm(2) PCD with a 0.75 mm CdTe layer, two energy thresholds, and 0.1 mm pixels was integrated with a Siemens Artis Zee interventional imaging system. The PCD can be translated in and out of the field-of-view to allow the system to switch between FPD and PCD-CT imaging modes. A dedicated phantom and a new algorithm were developed to calibrate the projection geometry of the narrow-beam PCD-CT system and correct the gantry wobbling-induced geometric distortion artifacts. In addition, a detector response calibration procedure was performed for each PCD pixel using materials with known radiological pathlengths to address concentric artifacts in PCD-CT images. Both phantom and human cadaver experiments were performed at a high gantry rotation speed and clinically relevant radiation dose level to evaluate the spectral and non-spectral imaging performance of the prototype system. Results show that the PCD-CT system has excellent image quality with negligible artifacts after the proposed corrections. Compared with FPD-CBCT images acquired at the same dose level, PCD-CT images demonstrated a 53% reduction in noise variance and additional quantitative imaging capability.
引用
收藏
页码:3674 / 3685
页数:12
相关论文
共 50 条
  • [21] Artifact Reduction of Different Metallic Implants in Flat Detector C-Arm CT
    Hung, S. -C.
    Wu, C. -C.
    Lin, C. -J.
    Guo, W. -Y.
    Luo, C. -B.
    Chang, F. -C.
    Chang, C. -Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1288 - 1292
  • [22] Update On the Development of a New Dual Detector (Micro-Angiographic Fluoroscope/Flat Panel) C-Arm Mounted System for Endovascular Image Guided Interventions (EIGI)
    Ionita, C.
    Patel, V.
    Keleshis, C.
    Bednarek, D.
    Hoffmann, K.
    Rudin, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [23] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [24] Image performance of photon-counting imaging detector with wedge-and-strip anode
    He, Ling-Ping
    Ni, Qi-Liang
    Li, Min
    Liu, Shi-Jie
    Chen, Bo
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (11): : 2699 - 2704
  • [25] A Dagger (†) Photon Counting Detector System for both 2D and 3D Interventional Imaging
    Treb, Kevin
    Ji, Xu
    Periyasamy, Sarvesh
    Feng, Mang
    Zhang, Ran
    Bushe, Dan
    Laeseke, Paul
    Li, Ke
    [J]. MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [26] X-ray Integrated Digital Imaging System Based on a-si Flat Panel Detector
    Fu Jian
    Li Bin
    Jiang Baihong
    [J]. 5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTOELECTRONIC MATERIALS AND DEVICES FOR DETECTOR, IMAGER, DISPLAY, AND ENERGY CONVERSION TECHNOLOGY, 2010, 7658
  • [27] A photon-counting camera system developed from a crossed-strip detector
    Cook, Jonathan M.
    Palmer, Joseph M.
    Rabin, Ellen C. S.
    Stonehill, Laura C.
    Thompson, David C.
    Whittemore, Stephen R.
    Ulibarri, Michael D.
    [J]. BIOSENSING AND NANOMEDICINE V, 2012, 8460
  • [28] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6709 - 6727
  • [29] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [30] Volume-of-interest, (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose
    Kolditz, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2719 - 2730