Evaluating the four-dimensional cone beam computed tomography with varying gantry rotation speed

被引:13
|
作者
Yoganathan, S. A. [1 ]
Maria, K. J. [1 ]
Ali, Shajahan Mohamed [2 ]
Agarwal, Arpita [1 ]
Mishra, Surendra P. [2 ]
Kumar, Shaleen [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Deparment Radiotherapy, Lucknow, Uttar Pradesh, India
[2] Dr Ram Manohar Lohia Inst Med Sci, Dept Radiat Oncol, Lucknow, Uttar Pradesh, India
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1060期
关键词
RADIATION-THERAPY; ADAPTIVE RADIOTHERAPY; CT RECONSTRUCTION; TARGET MARGINS; INTRA-FRACTION; MOTION MODEL; TUMOR MOTION; LUNG; VOLUME; VERIFICATION;
D O I
10.1259/bjr.20150870
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this work was to evaluate the four-dimensional cone beam CT (4DCBCT) imaging with different gantry rotation speed. Methods: All the 4DCBCT image acquisitions were carried out in Elekta XVI Symmetry (TM) system (Elekta AB, Stockholm, Sweden). A dynamic thorax phantom with tumour mimicking inserts of diameter 1, 2 and 3 cm was programmed to simulate the respiratory motion (4 s) of the target. 4DCBCT images were acquired with different gantry rotation speeds (36 degrees, 50 degrees, 75 degrees, 100 degrees, 150 degrees and 200 degrees min(-1)). Owing to the technical limitation of 4DCBCT system, average cone beam CT (CBCT) images derived from the 10 phases of 4DCBCT were used for the internal target volume (ITV) contouring. ITVs obtained from average CBCT were compared with the four-dimensional CT (4DCT). In addition, the image quality of 4DCBCT was also evaluated for various gantry rotation speeds using Catphan (R) 600 (The Phantom Laboratory Inc., Salem, NY). Results: Compared to 4DCT, the average CBCT underestimated the ITV. The ITV deviation increased with increasing gantry speed (210.8% vs 217.8% for 36 degrees and 200 degrees min(-1) in 3-cm target) and decreasing target size (217.8% vs 226.8% for target diameter 3 and 1 cm in 200 degrees min(-1)). Similarly, the image quality indicators such as spatial resolution, contrast-to-noise ratio and uniformity also degraded with increasing gantry rotation speed. Conclusion: The impact of gantry rotation speed has to be considered when using 4DCBCT for ITV definition. The phantom study demonstrated that 4DCBCT with slow gantry rotation showed better image quality and less ITV deviation. Advances in knowledge: Usually, the gantry rotation period of Elekta 4DCBCT system is kept constant at 4min (50 degrees min(-1)) for acquisition, and any attempt of decreasing/increasing the acquisition duration requires careful investigation. In this study, the 4DCBCT images with different gantry rotation speed were evaluated.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Four-Dimensional Cone-Beam Computed Tomography Image Compression Using Video Encoder for Radiotherapy
    Hui Yan
    Yexiong Li
    Jianrong Dai
    Journal of Digital Imaging, 2020, 33 : 1292 - 1300
  • [22] Four-Dimensional Cone-Beam Computed Tomography Image Compression Using Video Encoder for Radiotherapy
    Yan, Hui
    Li, Yexiong
    Dai, Jianrong
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (05) : 1292 - 1300
  • [23] High temporal resolution and streak-free four-dimensional cone-beam computed tomography
    Leng, Shuai
    Tang, Jie
    Zambelli, Joseph
    Nett, Brian
    Tolakanahalli, Ranjini
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5653 - 5673
  • [24] Kinematic analysis of forearm rotation using four-dimensional computed tomography
    Oonk, Joris G. M.
    Dobbe, Johannes G. G.
    Strijkers, Gustav J.
    Van Rijn, Sybren K.
    Streekstra, Geert J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 466 - 475
  • [25] High Temporal Resolution and Streak-Free Four-Dimensional Cone-Beam Computed Tomography
    Leng, S.
    Tang, J.
    Zambelli, J.
    Nett, B.
    Tolakanahalli, R.
    Chen, G.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [26] On the evaluation of mobile target trajectory between four-dimensional computer tomography and four-dimensional cone-beam computer tomography
    Baley, Colton
    Kirby, Neil
    Wagner, Timothy
    Papanikolaou, Nikos
    Myers, Pamela
    Rasmussen, Karl
    Stathakis, Sotirios
    Saenz, Daniel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 198 - 207
  • [27] A longitudinal four-dimensional computed tomography and cone beam computed tomography dataset for image-guided radiation therapy research in lung cancer
    Hugo, Geoffrey D.
    Balik, Salim
    Keall, Paul J.
    Lu, Jun
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2017, 44 (02) : 762 - 771
  • [28] Optimization of four-dimensional cone-beam computed tomography in image-guided radiation therapy of the lung
    Ahmad, Moiz
    Pan, Tinsu
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [29] A cycle generative adversarial network for improving the quality of four-dimensional cone-beam computed tomography images
    Keisuke Usui
    Koichi Ogawa
    Masami Goto
    Yasuaki Sakano
    Shinsuke Kyougoku
    Hiroyuki Daida
    Radiation Oncology, 17
  • [30] Application of four-dimensional cone beam computed tomography in lung cancer radiotherapy (vol 18, 69, 2023)
    Abulimiti, Muyasha
    Yang, Xu
    Li, Minghui
    Huan, Fukui
    Zhang, Yanxin
    Jun, Liang
    RADIATION ONCOLOGY, 2023, 18 (01)