Transcatheter aortic valve replacement in bicuspid valves: The synergistic effects of eccentric and incomplete stent deployment

被引:13
|
作者
Qiu, Dong [1 ]
Barakat, Mohammed [1 ]
Hopkins, Brenna [1 ]
Ravaghi, Saba [1 ]
Azadani, Ali N. [1 ]
机构
[1] Univ Denver, Dept Mech & Mat Engn, 2155 E Wesley Ave,Room 439, Denver, CO 80208 USA
关键词
Transcatheter aortic valve replacement; Bicuspid aortic valves; Finite element simulations; Eccentric stent deployment; Valve oversizing; SUBCLINICAL LEAFLET THROMBOSIS; FINITE-ELEMENT-ANALYSIS; BLOOD STASIS; IMPLANTATION; SIMULATION; COREVALVE; GEOMETRY; STENOSIS; OUTCOMES; SYSTEM;
D O I
10.1016/j.jmbbm.2021.104621
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bicuspid aortic valve is a congenital cardiac anomaly and common etiology of aortic stenosis. Given the positive outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients, TAVR will become more prevalent in the future in the treatment of severe bicuspid valve stenosis. However, asymmetrical bicuspid valve anatomy and calcification can prevent the circular and complete expansion of transcatheter aortic valves (TAVs). In previous studies, examining the impact of elliptical TAV deployment on leaflet stress distribution, asymmetric expansion of balloon-expandable intra-annular devices was studied up to an ellipticity index (long/short TAV diameter) of 1.4. However, such a high degree of eccentricity has not been observed in clinical studies with balloon-expandable devices. High degrees of stent eccentricity have been observed in self-expanding TAVs, such as CoreValve. However, CoreValve is a supra-annular device, and it was not clear if eccentric and incomplete stent deployment at the annulus would alter leaflet stress and strain distributions. This study aimed to assess the effects of eccentric and incomplete stent deployment of CoreValves in bicuspid aortic valves and compare the results to that of SAPIEN 3. Leaflet stress distribution and leaflet kinematics of 26-mm CoreValve and 26-mm SAPIEN 3 devices in bicuspid valves were obtained in a range that was observed in previous clinical studies. The results indicated that elliptical and incomplete stent deployment of TAVs increase leaflet stress and impair leaflet kinematics. The changes were more pronounced in CoreValve than SAPIEN 3. Increased leaflet stress can reduce long-term valve durability, and impaired leaflet kinematics can potentially increase blood stasis on the TAV leaflets. The study provides complementary insights into the mechanics of TAVs in bicuspid aortic valves.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Bicuspid Aortic Valve Morphology and Outcomes After Transcatheter Aortic Valve Replacement
    Yoon, Sung-Han
    Kim, Won-Keun
    Dhoble, Abhijeet
    Pio, Stephan Milhorini
    Babaliaros, Vasilis
    Jilaihawi, Hasan
    Pilgrim, Thomas
    De Backer, Ole
    Bleiziffer, Sabine
    Vincent, Flavien
    Schmidit, Tobias
    Butter, Christian
    Kamioka, Norihiko
    Eschenbach, Lena
    Renker, Matthias
    Asami, Masahiko
    Lazkani, Mohamad
    Fujita, Buntaro
    Birs, Antoinette
    Barbanti, Marco
    Pershad, Ashish
    Landes, Uri
    Oldemeyer, Brad
    Kitamura, Mitusnobu
    Oakley, Luke
    Ochiai, Tomoki
    Chakravarty, Tarun
    Nakamura, Mamoo
    Ruile, Philip
    Deuschl, Florian
    Berman, Daniel
    Modine, Thomas
    Ensminger, Stephan
    Kornowski, Ran
    Lange, Rudiger
    McCabe, James M.
    Williams, Mathew R.
    Whisenant, Brian
    Delgado, Victoria
    Windecker, Stephan
    Van Belle, Eric
    Sondergaard, Lars
    Chevalier, Bernard
    Mack, Michael
    Bax, Jeroen J.
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (09) : 1018 - 1030
  • [32] Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves
    He, Jingjing
    Xiong, Tian-Yuan
    Yao, Yi-Jun
    Peng, Yong
    Wei, Jia-Fu
    Zhao, Zhen-Gang
    Chen, Guo
    Ou, Yuan-Weixiang
    Liu, Qi
    Wang, Xi
    Zhu, Zhongkai
    Yang, Hao-Ran
    Jia, Kaiyu
    Mylotte, Darren
    Piazza, Nicolo
    Prendergast, Bernard
    Feng, Yuan
    Chen, Mao
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (12) : E013083
  • [33] Clinical Outcomes of Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis
    Yoon, Sung-Han
    Lefevre, Thierry
    Dvir, Danny
    Ahn, Jung-Min
    Arai, Takahide
    Kim, Young-Hak
    Watanabe, Yusuke
    Kao, Paul Hsien-Li
    Yong, Gerald
    Yin, Wei-Hsian
    Lee, Michael Kang-Yin
    Tay, Edgar L.
    Kim, Hyo-Soo
    Chevalier, Bernard
    Morice, Marie-Claude
    John, Webb
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B48 - B48
  • [34] Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Aortic Valves From the STS/ACC TVT Registry
    Forrest, John K.
    Kaple, Ryan K.
    Ramlawi, Basel
    Gleason, Thomas G.
    Meduri, Christopher U.
    Yakubov, Steven J.
    Jilaihawi, Hasan
    Liu, Fang
    Reardon, Michael J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1749 - 1759
  • [35] Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies
    Reddy, Gautam
    Wang, Zhen
    Nishimura, Rick A.
    Greason, Kevin L.
    Yoon, Sung-Han
    Makkar, Raj R.
    Holmes, David R., Jr.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (05) : 975 - 983
  • [36] Network Analysis of Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement for Stenotic Bicuspid Aortic Valves According to Valve Type
    Quintana, Raymundo A.
    Monlezun, Dominique
    Davogustto, Giovanni
    Saenz, Humberto
    Baruqui, Diego Lugo
    Denktas, Ali E.
    Jneid, Hani
    Paniagua, David
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (09) : 1076 - 1085
  • [37] The selection of transcatheter heart valves in transcatheter aortic valve replacement
    Tugaoen, Zachary
    Nguyen, Peter
    Arora, Sameer
    Vavalle, John
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (08) : 513 - 522
  • [38] Transcatheter Aortic Valve Replacement in Failed Transcatheter Bioprosthetic Valves
    Tarantini, Giuseppe
    Sathananthan, Janarthanan
    Fabris, Tommaso
    Landes, Uri
    Bapat, Vinayak N.
    Khan, Jaffar M.
    Fovino, Luca Nai
    Zaid, Syed
    Van Mieghem, Nicolas M.
    Latib, Azeem
    Waksman, Ron
    De Backer, Ole
    Rogers, Toby
    Sondergaard, Lars
    Tang, Gilbert H. L.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (18) : 1777 - 1793
  • [39] Transcatheter aortic valve replacement for patients with severe bicuspid aortic stenosis
    Pineda, Andres M.
    Rymer, Jennifer
    Wang, Alice
    Banks, Adam Z.
    Koweek, Lynne H.
    Plichta, Ryan
    Williams, Adam
    Vavalle, John P.
    Halim, Sharif
    Kiefer, Todd
    Wang, Andrew
    Gaca, Jeffrey
    Hughes, G. Chad
    Harrison, J. Kevin
    AMERICAN HEART JOURNAL, 2020, 224 : 105 - 112
  • [40] Valve-preserving root replacement in bicuspid aortic valves
    Schaefers, Hans-Joachim
    Kunihara, Takashi
    Fries, Peter
    Brittner, Brigitte
    Aicher, Diana
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06): : S36 - S40