Transcatheter aortic valve replacement in bicuspid valves: The synergistic effects of eccentric and incomplete stent deployment

被引:13
|
作者
Qiu, Dong [1 ]
Barakat, Mohammed [1 ]
Hopkins, Brenna [1 ]
Ravaghi, Saba [1 ]
Azadani, Ali N. [1 ]
机构
[1] Univ Denver, Dept Mech & Mat Engn, 2155 E Wesley Ave,Room 439, Denver, CO 80208 USA
关键词
Transcatheter aortic valve replacement; Bicuspid aortic valves; Finite element simulations; Eccentric stent deployment; Valve oversizing; SUBCLINICAL LEAFLET THROMBOSIS; FINITE-ELEMENT-ANALYSIS; BLOOD STASIS; IMPLANTATION; SIMULATION; COREVALVE; GEOMETRY; STENOSIS; OUTCOMES; SYSTEM;
D O I
10.1016/j.jmbbm.2021.104621
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bicuspid aortic valve is a congenital cardiac anomaly and common etiology of aortic stenosis. Given the positive outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients, TAVR will become more prevalent in the future in the treatment of severe bicuspid valve stenosis. However, asymmetrical bicuspid valve anatomy and calcification can prevent the circular and complete expansion of transcatheter aortic valves (TAVs). In previous studies, examining the impact of elliptical TAV deployment on leaflet stress distribution, asymmetric expansion of balloon-expandable intra-annular devices was studied up to an ellipticity index (long/short TAV diameter) of 1.4. However, such a high degree of eccentricity has not been observed in clinical studies with balloon-expandable devices. High degrees of stent eccentricity have been observed in self-expanding TAVs, such as CoreValve. However, CoreValve is a supra-annular device, and it was not clear if eccentric and incomplete stent deployment at the annulus would alter leaflet stress and strain distributions. This study aimed to assess the effects of eccentric and incomplete stent deployment of CoreValves in bicuspid aortic valves and compare the results to that of SAPIEN 3. Leaflet stress distribution and leaflet kinematics of 26-mm CoreValve and 26-mm SAPIEN 3 devices in bicuspid valves were obtained in a range that was observed in previous clinical studies. The results indicated that elliptical and incomplete stent deployment of TAVs increase leaflet stress and impair leaflet kinematics. The changes were more pronounced in CoreValve than SAPIEN 3. Increased leaflet stress can reduce long-term valve durability, and impaired leaflet kinematics can potentially increase blood stasis on the TAV leaflets. The study provides complementary insights into the mechanics of TAVs in bicuspid aortic valves.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Outcomes of transcatheter aortic valve replacement in bicuspid aortic valve stenosis
    Bob-Manuel, Tamunoinemi
    Heckle, Mark R.
    Ifedili, Ikechukwu A.
    Wang, Jiajing
    Ibebuogu, Uzoma N.
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (05)
  • [22] Feasibility of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve
    Tsujisaka, Yuta
    Toyota, Toshiaki
    Ehara, Natsuhiko
    Kim, Kitae
    Kitai, Takeshi
    Pak, Misun
    Sasaki, Yasuhiro
    Kobori, Atsushi
    Kinoshita, Makoto
    Kaji, Shuichiro
    Furukawa, Yutaka
    CIRCULATION, 2019, 140
  • [23] Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve
    Husso, Annastiina
    Airaksinen, Juhani
    Juvonen, Tatu
    Laine, Mika
    Dahlbacka, Sebastian
    Virtanen, Marko
    Niemela, Matti
    Makikallio, Timo
    Savontaus, Mikko
    Eskola, Markku
    Raivio, Peter
    Valtola, Antti
    Biancari, Fausto
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (03) : 429 - 439
  • [24] IMPROVING TRANSCATHETER AORTIC VALVE REPLACEMENT OUTCOMES IN BICUSPID AORTIC VALVES THROUGH A PREOPERATIVE COMPUTATIONAL APPROACH
    Yeats, Breandan
    Sivakumar, Sri Krishna
    Polsani, Venkateshwar
    Yadav, Pradeep
    Thourani, Vinod
    Dasi, Lakshmi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1180 - 1180
  • [25] Transcatheter Aortic Valve Replacement in a Bicuspid Aortic Valve With Type A Aortic Dissection
    Putthapiban, Prapaipan
    Alani, Anas
    Jutzy, Kenneth
    Abudayyeh, Islam
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (18) : E243 - E245
  • [26] Transcatheter aortic valve replacement for a bicuspid aortic valve following replacement of the ascending aorta
    Nardi, Paolo
    Russo, Marco
    Saitto, Guglielmo
    Ussia, Gian Paolo
    Ruvolo, Giovanni
    JOURNAL OF CARDIAC SURGERY, 2017, 32 (06) : 355 - 357
  • [27] Bioprosthetic Valves for Transcatheter Aortic Valve Replacement
    Reardon, Michael J.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (08): : 844 - 845
  • [28] Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves
    De Biase, Chiara
    Mastrokostopoulos, Antonios
    Philippart, Raphael
    Desroche, Louis Marie
    Blanco, Stephanie
    Rehal, Kamel
    Dumonteil, Nicolas
    Tchetche, Didier
    DATA IN BRIEF, 2018, 17 : 667 - 670
  • [29] Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves
    De Biase, C.
    Mastrokostopoulos, A.
    Philippart, R.
    Desroche, L. M.
    Blanco, S.
    Rehal, K.
    Dumonteil, N.
    Tchetche, D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 266 : 56 - 60
  • [30] Transcatheter and Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis
    Sanaiha, Yas
    Hadaya, Joseph E.
    Tran, Zachary
    Shemin, Richard J.
    Benharash, Peyman
    ANNALS OF THORACIC SURGERY, 2023, 115 (03): : 611 - 618