Transcatheter aortic valve replacement in bicuspid valves: The synergistic effects of eccentric and incomplete stent deployment

被引:11
|
作者
Qiu, Dong [1 ]
Barakat, Mohammed [1 ]
Hopkins, Brenna [1 ]
Ravaghi, Saba [1 ]
Azadani, Ali N. [1 ]
机构
[1] Univ Denver, Dept Mech & Mat Engn, 2155 E Wesley Ave,Room 439, Denver, CO 80208 USA
关键词
Transcatheter aortic valve replacement; Bicuspid aortic valves; Finite element simulations; Eccentric stent deployment; Valve oversizing; SUBCLINICAL LEAFLET THROMBOSIS; FINITE-ELEMENT-ANALYSIS; BLOOD STASIS; IMPLANTATION; SIMULATION; COREVALVE; GEOMETRY; STENOSIS; OUTCOMES; SYSTEM;
D O I
10.1016/j.jmbbm.2021.104621
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bicuspid aortic valve is a congenital cardiac anomaly and common etiology of aortic stenosis. Given the positive outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients, TAVR will become more prevalent in the future in the treatment of severe bicuspid valve stenosis. However, asymmetrical bicuspid valve anatomy and calcification can prevent the circular and complete expansion of transcatheter aortic valves (TAVs). In previous studies, examining the impact of elliptical TAV deployment on leaflet stress distribution, asymmetric expansion of balloon-expandable intra-annular devices was studied up to an ellipticity index (long/short TAV diameter) of 1.4. However, such a high degree of eccentricity has not been observed in clinical studies with balloon-expandable devices. High degrees of stent eccentricity have been observed in self-expanding TAVs, such as CoreValve. However, CoreValve is a supra-annular device, and it was not clear if eccentric and incomplete stent deployment at the annulus would alter leaflet stress and strain distributions. This study aimed to assess the effects of eccentric and incomplete stent deployment of CoreValves in bicuspid aortic valves and compare the results to that of SAPIEN 3. Leaflet stress distribution and leaflet kinematics of 26-mm CoreValve and 26-mm SAPIEN 3 devices in bicuspid valves were obtained in a range that was observed in previous clinical studies. The results indicated that elliptical and incomplete stent deployment of TAVs increase leaflet stress and impair leaflet kinematics. The changes were more pronounced in CoreValve than SAPIEN 3. Increased leaflet stress can reduce long-term valve durability, and impaired leaflet kinematics can potentially increase blood stasis on the TAV leaflets. The study provides complementary insights into the mechanics of TAVs in bicuspid aortic valves.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] The Synergistic Impact of Eccentric and Incomplete Stent Deployment on Transcatheter Aortic Valve Leaflet Stress Distribution
    Abbasi, Mostafa
    Azadani, Ali N.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B253 - B254
  • [2] Transcatheter aortic valve replacement in patients with bicuspid aortic valves
    Patel, Amisha
    Leon, Martin B.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S3568 - S3572
  • [3] Transcatheter aortic valve replacement outcomes in bicuspid compared to trileaflet aortic valves
    Nagaraja, Vinayak
    Suh, William
    Fischman, David L.
    Banning, Adrian
    Martinez, Sara C.
    Potts, Jessica
    Kwok, Chun Shing
    Ratib, Karim
    Nolan, Jim
    Bagur, Rodrigo
    Mamas, Mamas A.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (01) : 50 - 56
  • [4] ELEVATED AORTIC GRADIENTS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT IN BICUSPID AORTIC VALVES
    Tsangaris, Adamantios
    Reiff, Chris
    Hall, Alexandra
    Raveendran, Ganesh
    Kelly, Rosemary
    Yannopoulos, Demetris
    Gurevich, Sergey
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1251 - 1251
  • [5] Early and midterm outcomes of transcatheter aortic valve replacement in patients with bicuspid aortic valves
    Aalaei-Andabili, Seyed Hossein
    Beaver, Thomas M.
    Petersen, John W.
    Anderson, R. David
    Karimi, Ashkan
    Thoburn, Eric
    Kabir, Ali
    Bavry, Anthony A.
    Arnaoutakis, George J.
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (09) : 489 - 496
  • [6] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis
    Vincent, Flavien
    Ternacle, Julien
    Denimal, Tom
    Shen, Mylene
    Redfors, Bjorn
    Delhaye, Cedric
    Simonato, Matheus
    Debry, Nicolas
    Verdier, Basile
    Shahim, Bahira
    Pamart, Thibault
    Spillemaeker, Hugues
    Schurtz, Guillaume
    Pontana, Francois
    Thourani, Vinod H.
    Pibarot, Philippe
    Van Belle, Eric
    CIRCULATION, 2021, 143 (10) : 1043 - 1061
  • [7] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease
    Mylotte, Darren
    Lefevre, Thierry
    Sondergaard, Lars
    Watanabe, Yusuke
    Modine, Thomas
    Dvir, Danny
    Bosmans, Johan
    Tchetche, Didier
    Kornowski, Ran
    Sinning, Jan-Malte
    Theriault-Lauzier, Pascal
    O'Sullivan, Crochan J.
    Barbanti, Marco
    Debry, Nicolas
    Buithieu, Jean
    Codner, Pablo
    Dorfmeister, Magdalena
    Martucci, Giuseppe
    Nickenig, Georg
    Wenaweser, Peter
    Tamburino, Corrado
    Grube, Eberhard
    Webb, John G.
    Windecker, Stephan
    Lange, Ruediger
    Piazza, Nicolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (22) : 2330 - 2339
  • [8] Transcatheter aortic valve replacement in bicuspid aortic valve stenosis
    Yoon, Sung-Han
    Webb, John G.
    Leon, Martin B.
    Makkar, Raj
    PROGRESS IN CARDIOVASCULAR DISEASES, 2020, 63 (04) : 482 - 487
  • [9] Successful Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve
    Maeda, Koichi
    Kuratani, Toru
    Torikai, Kei
    Shimamura, Kazuo
    Ueno, Takayoshi
    Toda, Koichi
    Sawa, Yoshiki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 : 705 - 708
  • [10] Transcatheter aortic valve replacement for bicuspid aortic valve stenosis
    Kayani, Waleed T.
    Blaustein, Alvin
    Denktas, Ali
    Jneid, Hani
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 2018, 85 (10) : 786 - 788