Evaluation of residual patient position variation for spinal radiosurgery using the Novalis image guided system

被引:30
|
作者
Jin, Jian-Yue [1 ]
Ryu, Samuel [1 ,2 ]
Rock, Jack [2 ]
Faber, Kathleen [1 ]
Chen, Qing [1 ]
Ajlouni, Munther [1 ]
Movsas, Benjamin [1 ]
机构
[1] Henry Ford Hosp, Dept Radiat Oncol, Detroit, MI 48202 USA
[2] Henry Ford Hosp, Dept Neurosurg, Detroit, MI 48202 USA
关键词
spinal radiotherapy; image guided radiotherapy; position uncertainty; image fusion; intrafraction motion;
D O I
10.1118/1.2839097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Novalis system has been demonstrated to achieve accurate target localization on anthropomorphic phantoms. However, other factors, such as rotational deviation, patient intrafraction motion, and image fusion uncertainty due to patient body deformation, could contribute additional position uncertainty for actual patients. This study evaluates such position uncertainty for spinal radiosurgery patients. Materials and Methods: Fifty-two consecutive spinal radiosurgery patients were included in the study. Rotational deviation was evaluated from 6-deg of freedom (6D) fusion results for all patients. The combined uncertainty of patient motion and image fusion was determined from fusion results of additional kV x-ray images acquired before, during, and after treatment for 25 of the 52 patients. The uncertainty of image fusion was also evaluated by performing 6D fusion ten different times with various regions of interest in the images selected for fusion. This was performed for two patients with L3 and T2 lesions, respectively, for comparison. Results: The mean rotational deviation was 0.7 +/- 1.8, 0.7 +/- 1.5, and 0.7 +/- 1.6 deg along the yaw, roll, and pitch directions, respectively. The combined uncertainty from patient motion and image fusion was 0.1 +/- 0.9, 0.2 +/- 1.2, and 0.2 +/- 1.0 mm in the anteroposterior (AP), longitudinal, and lateral directions, respectively. The uncertainty (standard deviation) due to image fusion was less than 0.28 mm in any direction for the L3 lesion and 0.8 mm in the AP direction for the T2 lesion. Conclusion: Overall position uncertainty for spinal radiosurgery patients has been evaluated. Rotational deviation and patient motion were the main factors contributed to position uncertainty for actual patient treatment. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1087 / 1093
页数:7
相关论文
共 50 条
  • [21] Image-guided stereotactic radiosurgery for treatment of spinal hemangioblastoma
    Pan, James
    Ho, Allen L.
    D'Astous, Myreille
    Sussman, Eric S.
    Thompson, Patricia A.
    Tayag, Armine T.
    Pangilinan, Louisa
    Soltys, Scott G.
    Gibbs, Iris C.
    Chang, Steven D.
    NEUROSURGICAL FOCUS, 2017, 42 (01)
  • [22] Image-guided radiosurgery for single spinal metastasis.
    Ryu, S
    Rock, J
    Yin, FF
    Ajlouni, M
    Rosenblum, M
    Kim, JH
    JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (14) : 737S - 737S
  • [23] Fractionated Stereotactic Radiosurgery for Brain Metastases Using the Novalis Tx® System
    Lim, Tae Kyoo
    Kim, Woo Kyung
    Yoo, Chan Jong
    Kim, Eun Young
    Kim, Myeong Jin
    Yee, Gi Taek
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2018, 61 (04) : 525 - 529
  • [24] Evaluation of CyberKnife frameless real-time image-guided stereotactic radiosurgery for spinal lesions
    Gerszten, PC
    Ozhasoglu, C
    Burton, SA
    Vogel, W
    Atkins, B
    Kalnicki, S
    Welch, WC
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2003, 81 (1-4) : 84 - 89
  • [25] Pain control by image-guided radiosurgery for solitary spinal metastasis
    Ryu, Samuel
    Jin, Ryan
    Jin, Jian-Yue
    Chen, Qing
    Rock, Jack
    Anderson, Joseph
    Movsas, Benjamin
    JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 2008, 35 (03) : 292 - 298
  • [26] Image guided linac spinal radiosurgery for benign nerve sheath tumors
    Selch, M. T.
    Agazaryan, N.
    DeMarco, J. J.
    Gorgulho, A.
    DeSalles, A. A. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S212 - S212
  • [27] An image-guided technique for intensity-modulated spinal radiosurgery
    Yin, F
    Ryu, S
    Ajlouni, M
    Zhu, J
    Yan, H
    Guan, H
    RADIOLOGY, 2002, 225 : 362 - 362
  • [28] Image-guided spinal radiosurgery for epidural compression of multiple myeloma
    Jin, R.
    Rock, J.
    Ajlouni, M.
    Anderson, J.
    Jin, J.
    Massanisso, L.
    Faber, K.
    Movsas, B.
    Ryu, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S244 - S244
  • [29] Evaluation of patient setup uncertainty of optical guided frameless system for intracranial stereotactic radiosurgery
    Wang, Jia-Zhu
    Rice, Roger
    Pawlicki, Todd
    Mundt, Arno J.
    Sandhu, Ajay
    Lawson, Joshua
    Murphy, Kevin T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 92 - 100
  • [30] Dosimetric Effect of Patient Arm Position in Spinal CyberKnife Robotic Radiosurgery
    Mihaylov, I. B.
    Tien, C. J.
    Hepel, J. T.
    MEDICAL PHYSICS, 2013, 40 (06)