Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography

被引:35
|
作者
Golatta, Michael [1 ]
Baggs, Christina [1 ]
Schweitzer-Martin, Mirjam [1 ]
Domschke, Christoph [1 ]
Schott, Sarah [1 ]
Harcos, Aba [1 ]
Scharf, Alexander [1 ]
Junkermann, Hans [1 ]
Rauch, Geraldine [2 ]
Rom, Joachim [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
关键词
Ultrasound; Breast; Automated three-dimensional breast ultrasound; 3D scanning; BI-RADS((R)); VOLUME SCANNER; LESION DETECTION; DENSE BREASTS; SONOGRAPHY; CANCER; AGREEMENT; DIAGNOSIS; US; CLASSIFICATION; CARCINOMA;
D O I
10.1007/s00404-014-3509-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patientsA ' history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95 % CI [0.26;0.36], p < 0.0001) and 0.25 (95 % CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98 %, a high specificity of 85 % and a sensitivity of 74 % based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84 % (NPV = 99 %, specificity = 85 %). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [31] 3D-ultrasound diagnosis in breast masses: Merits and limitations
    Chung, SY
    Yang, I
    Lee, KW
    Lee, Y
    Bae, SH
    RADIOLOGY, 1998, 209P : 149 - 149
  • [32] A prospective study of a hand-held ultrasound device in abdominal aortic aneurysm evaluation
    Lin, PH
    Bush, RL
    McCoy, SA
    Felkai, D
    Pasnelli, TK
    Nelson, JC
    Watts, K
    Lam, RC
    Lumsden, AB
    AMERICAN JOURNAL OF SURGERY, 2003, 186 (05): : 455 - 459
  • [33] Integration of intraoperative 3D-ultrasound in a commercial navigation system
    Sergeeva, O.
    Uhlemann, F.
    Schackert, G.
    Hergeth, C.
    Morgenstern, U.
    Steinmeier, R.
    ZENTRALBLATT FUR NEUROCHIRURGIE, 2006, 67 (04): : 197 - 203
  • [34] HIGH-FREQUENCY BREAST ULTRASOUND - HAND-HELD VERSUS AUTOMATED UNITS - EXAMINATION FOR PALPABLE MASS VERSUS SCREENING
    KIMMESMITH, C
    BASSETT, LW
    GOLD, RH
    JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (02) : 77 - 81
  • [35] Efficiency and impact factors of anatomical intelligence for breast and hand-held ultrasound in lesion detection
    Dai, Chaochao
    Bao, Lingyun
    Yan, Hongju
    Zhu, Luoxi
    Xu, Xiaojing
    Tan, Yanjuan
    Yu, Lifang
    Yang, Jing
    Jiang, Chenxiang
    Shen, Yingzhao
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (06) : 1039 - 1047
  • [36] Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG)
    Chen, He
    Han, Ming
    Jing, Hui
    Liu, Zhao
    Shang, Haitao
    Wang, Qiucheng
    Cheng, Wen
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 9193 - 9202
  • [37] Combination of digital mammography with semi-automated 3D breast ultrasound
    Kapur, A
    Carson, PL
    Eberhard, J
    Goodsitt, MM
    Thomenius, K
    Lokhandwalla, M
    Buckley, D
    Roubidoux, MA
    Helvie, MA
    Booi, RC
    LeCarpentier, GL
    Erkamp, RQ
    Chan, HP
    Fowlkes, JB
    Thomas, JA
    Landberg, CE
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (04) : 325 - 334
  • [38] Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations
    Choi, Woo Jung
    Cha, Joo Hee
    Kim, Hak Hee
    Shin, Hee Jung
    Kim, Hyunji
    Chae, Eun Young
    Hong, Min Ji
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (21) : 9101 - 9105
  • [39] Development of a hand-held 3D photoacoustic imaging system for breast cancer detection
    Al-Aabed, Hazem
    Roumeliotis, Michael
    Carson, Jeffrey J. L.
    PHOTONICS NORTH 2010, 2010, 7750
  • [40] A New Automated 3D Mapping And Labeling System for Routine Free Hand Ultrasound Examinations, Performance Evaluation in a Breast Phantom
    Caluser, C.
    Lum, B.
    Gheorghe, B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)