Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography

被引:35
|
作者
Golatta, Michael [1 ]
Baggs, Christina [1 ]
Schweitzer-Martin, Mirjam [1 ]
Domschke, Christoph [1 ]
Schott, Sarah [1 ]
Harcos, Aba [1 ]
Scharf, Alexander [1 ]
Junkermann, Hans [1 ]
Rauch, Geraldine [2 ]
Rom, Joachim [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
关键词
Ultrasound; Breast; Automated three-dimensional breast ultrasound; 3D scanning; BI-RADS((R)); VOLUME SCANNER; LESION DETECTION; DENSE BREASTS; SONOGRAPHY; CANCER; AGREEMENT; DIAGNOSIS; US; CLASSIFICATION; CARCINOMA;
D O I
10.1007/s00404-014-3509-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patientsA ' history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95 % CI [0.26;0.36], p < 0.0001) and 0.25 (95 % CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98 %, a high specificity of 85 % and a sensitivity of 74 % based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84 % (NPV = 99 %, specificity = 85 %). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [1] Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography
    Michael Golatta
    Christina Baggs
    Mirjam Schweitzer-Martin
    Christoph Domschke
    Sarah Schott
    Aba Harcos
    Alexander Scharf
    Hans Junkermann
    Geraldine Rauch
    Joachim Rom
    Christof Sohn
    Joerg Heil
    Archives of Gynecology and Obstetrics, 2015, 291 : 889 - 895
  • [2] Comparison of automated breast volume scanning to hand-held ultrasound and mammography
    Wang, Zhi Li
    Xw, Jian Hong
    Li, Jun Lai
    Huang, Yan
    Tang, Jie
    RADIOLOGIA MEDICA, 2012, 117 (08): : 1287 - 1293
  • [3] A Comparison of the Acceptance of Female Subjects Between Mammography, Automated Breast Ultrasound and Hand-Held Ultrasound
    Gao, Xican
    Liu, Liwen
    Yan, Jingru
    Yang, Shanling
    Shu, Rui
    Ju, Yan
    Zhang, Ge
    Xiao, Yao
    Song, Hongping
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (04) : 768 - 775
  • [4] Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts
    Philadelpho, Fernanda
    Gregorio Calas, Maria Julia
    Coutinho Carneiro, Gracy de Almeida
    Silveira, Isabela Cunha
    Ribeiro Vaz, Andreia Brandao
    Coelho Nogueira, Adriana Maria
    Bergmann, Anke
    Proenca Lobo Lopes, Flavia Paiva
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2021, 43 (03): : 190 - 199
  • [5] Breast ultrasound: automated or hand-held? Exploring patients’ experience and preference
    Ilaria Mussetto
    Licia Gristina
    Simone Schiaffino
    Simona Tosto
    Edoardo Raviola
    Massimo Calabrese
    European Radiology Experimental, 4
  • [6] Breast ultrasound: automated or hand-held? Exploring patients' experience and preference
    Mussetto, Ilaria
    Gristina, Licia
    Schiaffino, Simone
    Tosto, Simona
    Raviola, Edoardo
    Calabrese, Massimo
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [7] Automated breast ultrasound compared to hand-held ultrasound in surveillance after breast-conserving surgery
    Depretto, Catherine
    Liguori, Alessandro
    Primolevo, Alessandra
    Di Cosimo, Serena
    Cartia, Francesco
    Ferranti, Claudio
    Scaperrotta, Gianfranco P.
    TUMORI JOURNAL, 2021, 107 (02): : 132 - 138
  • [8] Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results
    Golatta, Michael
    Franz, Dorothea
    Harcos, Aba
    Junkermann, Hans
    Rauch, Geraldine
    Scharf, Alexander
    Schuetz, Florian
    Sohn, Christof
    Heil, Joerg
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : E332 - E336
  • [9] Evaluation of an automated breast volume scanner according to the fifth edition of BI-RADS for breast ultrasound compared with hand-held ultrasound
    Choi, Eun Jung
    Choi, Hyemi
    Park, Eun Hae
    Song, Ji Soo
    Youk, Ji Hyun
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 138 - 145
  • [10] Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound data
    Chang, Jung Min
    Moon, Woo Kyung
    Cho, Nariya
    Park, Jeong Seon
    Kim, Seung Ja
    ACTA RADIOLOGICA, 2011, 52 (01) : 8 - 14