Anatomical evidence for the anterior plate fixation of sacroiliac joint

被引:12
|
作者
Bai, Zhibiao [1 ]
Gao, Shichang [1 ]
Liu, Jia [2 ]
Liang, Anlin [1 ]
Yu, Weihua [3 ]
机构
[1] Chongqing Med Univ, Dept Orthoped Surg, Affiliated Hosp 1, Youyi Rd 1, Chongqing 400016, Peoples R China
[2] Fengdu Peoples Hosp Chongqing, Dept Orthoped Surg, Chongqing, Peoples R China
[3] Chongqing Med Univ, Dept Anat, Chongqing, Peoples R China
关键词
REDUCTION;
D O I
10.1016/j.jos.2017.09.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The iatrogenic injuries to the lumbar nerves during the fixation the sacroiliac (SI) joint fractures with anterior plates were often reported. No specific method had been reported to avoid it. This study was done to find a safer way of placing the anterior plates and screws for treating the sacroiliac (SI) joint fracture and/or dislocation. Methods: The research was performed using 8 male and 7 female normal corpse pelvic specimens preserved by 10% formalin solution. Try by measuring the horizontal distance from L4, L5 nerve roots to the sacroiliac joint and perpendicular distance from L4, L5 nerve roots to the ala sacralis, the length of L4, L5 nerve roots from intervertebral foramen to the edge of true pelvis, the diameter of L4, L5 nerve roots. The angles between the sacroiliac joint and sagittal plane were measured on the CT images. Results: The horizontal distance between the lateral side of the anterior branches of L4, L5 nerve roots and the sacroiliac joint decreased gradually from the top to the bottom. The widest distances for L4,5 were 2.1 cm (range, 1.74-2.40) and 2.7 cm (range, 2.34-3.02 cm), respectively. The smallest distances for L4, 5 were 1.2 cm (range, 0.82-1.48 cm) and 1.5 cm (range, 1.08-1.74 cm), respectively. On CT images, the angle between the sacroiliac joint and sagittal plane was about 30 degrees. Conclusions: If we use two anterior plates to fix the sacroiliac joint, It is recommended to place one plate on the superior one third part of the joint, with exposing medially no more than 2.5 cm and the other in the middle one third part of the joint, with elevating periosteum medially no more than 1.5 cm. The screws in the sacrum are advised to incline medially about 30 degrees directing to the true pelvis. (C) 2017 Published by Elsevier B.V. on behalf of The Japanese Orthopaedic Association.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [41] Anatomical Joint Form Variation in Sacroiliac Joint Disease: Current Concepts and New Perspectives
    Ziegeler, Katharina
    Hermann, Kay Geert A.
    Diekhoff, Torsten
    CURRENT RHEUMATOLOGY REPORTS, 2021, 23 (08)
  • [42] Percutaneous sacroiliac screw versus anterior plating for sacroiliac joint disruption: A retrospective cohort study
    Zhang, Ruipeng
    Yin, Yingchao
    Li, Shilun
    Hou, Zhiyong
    Jin, Lin
    Zhang, Yingze
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 50 : 11 - 16
  • [43] POSTERIOR SACROILIAC FIXATION USING A SACRAL PEDICLE TARGETING DEVICE - AN ANATOMICAL STUDY
    MILLER, MD
    CAIN, JE
    LAUERMAN, WC
    LITTLEFIELD, WG
    PLATENBERG, RC
    WILSON, MR
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (06) : 514 - 520
  • [44] Radio-anatomical study of anterior–posterior placement sacroiliac screw channel
    Tianfang Wang
    Changbao Wei
    Sanjun Gu
    Yongwei Wu
    Yu Liu
    Yunhong Ma
    Qudong Yin
    European Spine Journal, 2022, 31 : 2572 - 2578
  • [45] Mechanical behavior of the female sacroiliac joint and influence of the anterior and posterior sacroiliac ligaments under sagittal loads
    Department of Orthopaedic Surgery, University of Louisville, Louisville, KY 40292, United States
    不详
    Clin. Biomech., 4-5 (293-299):
  • [46] Biomechanics of sacroiliac joint fixation using lag screws: a cadaveric study
    Chatain, Gregoire P.
    Oldham, Alton
    Uribe, Juan
    Duhon, Bradley
    Gardner, Michael J.
    Witt, Jens-Peter
    Yerby, Scott
    Kelly, Brian P.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [47] Posterior hinge fixation for the treatment of unstable traumatic sacroiliac joint injuries
    Gauthe, Remi
    Lefevre, Emeric
    Dujardin, Franck
    Foulongne, Emmanuel
    Hoffmann, Etienne
    Lalevee, Matthieu
    Ould-Slimane, Mourad
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (02)
  • [48] Percutaneous Screw Fixation of Crescent Fracture-Dislocation of the Sacroiliac Joint
    Shui, Xiaolong
    Ying, Xiaozhou
    Mao, Chuanwan
    Feng, Yongzeng
    Chen, Linwei
    Kong, Jianzhong
    Guo, Xiaoshan
    Wang, Gang
    ORTHOPEDICS, 2015, 38 (11) : E976 - E982
  • [49] Die anteriore Stabilisierung der SakroilialgelenksprengungInternal Fixation of Sacroiliac Joint Disruption
    Axel Gänsslen
    Tim Pohlemann
    Christian Krettek
    Operative Orthopädie und Traumatologie, 2005, 17 (3) : 281 - 295
  • [50] CT-GUIDED FIXATION OF SACRAL FRACTURES AND SACROILIAC JOINT DISRUPTIONS
    NELSON, DW
    DUWELIUS, PJ
    RADIOLOGY, 1991, 180 (02) : 527 - 532