Anatomical evidence for the anterior plate fixation of sacroiliac joint

被引:12
|
作者
Bai, Zhibiao [1 ]
Gao, Shichang [1 ]
Liu, Jia [2 ]
Liang, Anlin [1 ]
Yu, Weihua [3 ]
机构
[1] Chongqing Med Univ, Dept Orthoped Surg, Affiliated Hosp 1, Youyi Rd 1, Chongqing 400016, Peoples R China
[2] Fengdu Peoples Hosp Chongqing, Dept Orthoped Surg, Chongqing, Peoples R China
[3] Chongqing Med Univ, Dept Anat, Chongqing, Peoples R China
关键词
REDUCTION;
D O I
10.1016/j.jos.2017.09.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The iatrogenic injuries to the lumbar nerves during the fixation the sacroiliac (SI) joint fractures with anterior plates were often reported. No specific method had been reported to avoid it. This study was done to find a safer way of placing the anterior plates and screws for treating the sacroiliac (SI) joint fracture and/or dislocation. Methods: The research was performed using 8 male and 7 female normal corpse pelvic specimens preserved by 10% formalin solution. Try by measuring the horizontal distance from L4, L5 nerve roots to the sacroiliac joint and perpendicular distance from L4, L5 nerve roots to the ala sacralis, the length of L4, L5 nerve roots from intervertebral foramen to the edge of true pelvis, the diameter of L4, L5 nerve roots. The angles between the sacroiliac joint and sagittal plane were measured on the CT images. Results: The horizontal distance between the lateral side of the anterior branches of L4, L5 nerve roots and the sacroiliac joint decreased gradually from the top to the bottom. The widest distances for L4,5 were 2.1 cm (range, 1.74-2.40) and 2.7 cm (range, 2.34-3.02 cm), respectively. The smallest distances for L4, 5 were 1.2 cm (range, 0.82-1.48 cm) and 1.5 cm (range, 1.08-1.74 cm), respectively. On CT images, the angle between the sacroiliac joint and sagittal plane was about 30 degrees. Conclusions: If we use two anterior plates to fix the sacroiliac joint, It is recommended to place one plate on the superior one third part of the joint, with exposing medially no more than 2.5 cm and the other in the middle one third part of the joint, with elevating periosteum medially no more than 1.5 cm. The screws in the sacrum are advised to incline medially about 30 degrees directing to the true pelvis. (C) 2017 Published by Elsevier B.V. on behalf of The Japanese Orthopaedic Association.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [21] ANTERIOR APPROACH AND STABILIZATION OF THE DISRUPTED SACROILIAC JOINT
    SIMPSON, LA
    WADDELL, JP
    LEIGHTON, RK
    KELLAM, JF
    TILE, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1987, 27 (12): : 1332 - 1339
  • [22] Anterior plate or halo fixation
    Sukoff, MH
    JOURNAL OF NEUROSURGERY, 2002, 97 (02) : 272 - 273
  • [23] C-2 anterior plate-screw fixation: a quantitative anatomical and morphometric evaluation
    Senoglu, M.
    Ozbag, D.
    Gumusalan, Y.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2010, 111 (10): : 566 - 569
  • [24] Anatomical Comparison of Radiofrequency Ablation Techniques for Sacroiliac Joint Pain
    Roberts, Shannon L.
    Stout, Alison
    Loh, Eldon Y.
    Swain, Nathan
    Dreyfuss, Paul
    Agur, Anne M.
    PAIN MEDICINE, 2018, 19 (10) : 1924 - 1943
  • [25] Anatomy of the anterior sacroiliac joint with reference to lumbosacral nerves
    Atlihan, D
    Tekdemir, I
    Ates, Y
    Elhan, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (376) : 236 - 241
  • [26] COMPLEX MOTION TOMOGRAPHY OF THE SACROILIAC JOINT - AN ANATOMICAL AND ROENTGENOLOGICAL STUDY
    DIJKSTRA, PF
    VLEEMING, A
    STOECKART, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1989, 150 (06): : 635 - 642
  • [27] The sacroiliac joint: Anatomical study in the coronal plane and MR correlation
    LeBlanche, AF
    Mabi, C
    Bigot, JM
    Rousseau, J
    Treves, R
    Outrequin, G
    Dupuy, JP
    Caix, M
    SURGICAL AND RADIOLOGIC ANATOMY, 1996, 18 (03) : 215 - 220
  • [28] A CONTOURED ANTERIOR SPINAL FIXATION PLATE
    BLACK, RC
    GARDNER, VO
    ARMSTRONG, GWD
    ONEIL, J
    STGEORGE, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (227) : 135 - 142
  • [29] Anterior plate or halo fixation - Response
    Haid, RW
    Subach, B
    JOURNAL OF NEUROSURGERY, 2002, 97 (02) : 273 - 273
  • [30] Critical distance of the sacroiliac joint for open reduction using screw fixation for traumatic sacroiliac joint diastasis: a retrospective study
    Chien, Ruei-Shyuan
    Chen, I-Jung
    Lai, Chih-Yang
    Chen, Jui-Ping
    Yu, Yi-Hsun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):