Evaluation of brachytherapy lung implant dose distributions from photon-emitting sources due to tissue heterogeneities

被引:9
|
作者
Yang, Yun [1 ]
Rivard, Mark J. [1 ]
机构
[1] Tufts Univ, Sch Med, Boston, MA 02111 USA
关键词
lung; brachytherapy; Monte Carlo; dosimetry; permanent implants; I-125; BRACHYTHERAPY; CANCER; DOSIMETRY; RESECTION; UPDATE;
D O I
10.1118/1.3641872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon-emitting brachytherapy sources are used for permanent implantation to treat lung cancer. However, the current brachytherapy dose calculation formalism assumes a homogeneous water medium without considering the influence of radiation scatter or tissue heterogeneities. The purpose of this study was to determine the dosimetric effects of tissue heterogeneities for permanent lung brachytherapy. Methods: The MCNP5 v1.40 radiation transport code was used for Monte Carlo (MC) simulations. Point sources with energies of 0.02, 0.03, 0.05, 0.1, 0.2, and 0.4 MeV were simulated to cover the range of pertinent brachytherapy energies and to glean dosimetric trends independent of specific radionuclide emissions. Source positions from postimplant CT scans of five patient implants were used for source coordinates, with dose normalized to 200 Gy at the center of each implant. With the presence of fibrosis (around the implant), cortical bone, lung, and healthy tissues, dose distributions and PTVDVH were calculated using the MCNP *FMESH4 tally and the NIST mass-energy absorption coefficients. This process was repeated upon replacing all tissues with water. For all photon energies, 10(9) histories were simulated to achieve statistical errors (k = 1) typically of 1%. Results: The mean PTV doses calculated using tissue heterogeneities for all five patients changed (compared to dose to water) by only a few percent over the examined photon energy range, as did PTV dose at the implant center. The V-PTV(100) values were 81.2%, 90.0% (as normalized), 94.3%, 93.9%, 92.7%, and 92.2% for 0.02, 0.03, 0.05, 0.1, 0.2, and 0.4 MeV source photons, respectively. Relative to water, the maximum bone doses were higher by factors of 3.7, 5.1, 5.2, 2.4, 1.2, and 1.0 The maximum lung doses were about 0.98, 0.94, 0.91, 0.94, 0.97, and 0.99. Relative to water, the maximum healthy tissue doses at the mediastinal position were higher by factors of 9.8, 2.2, 1.3, 1.1, 1.1, and 1.1. However, the maximum doses to these healthy tissues were only 3.1, 7.2, 11.3, 10.9, 9.0, and 8.1 Gy while maximum bone doses were 66, 177, 236, 106, 49, and 39 Gy, respectively. Similarly, maximum lung doses were 55, 66, 73, 74, 73, and 73 Gy, respectively. Conclusions: The current brachytherapy dose calculation formalism overestimates PTV dose and significantly underestimates doses to bone and healthy tissue. Further investigation using specific brachytherapy source models and patient-based CT datasets as MC input may indicate whether the observed trends can be generalized for low-energy lung brachytherapy dosimetry. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3641872]
引用
收藏
页码:5857 / 5862
页数:6
相关论文
共 30 条
  • [1] Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources
    Chen, Zhe Jay
    Nath, Ravinder
    MEDICAL PHYSICS, 2007, 34 (04) : 1412 - 1430
  • [2] Presentation of a matrix-based method to calculate dose distribution in brachytherapy with photon-emitting sources
    Ghorbani, Mahdi
    Mozaffari, Azam
    Akbari-Lalimi, Hossein
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (06) : 1245 - 1253
  • [3] Update of the CLRP eye plaque brachytherapy database for photon-emitting sources
    Safigholi, Habib
    Parsons, Zack
    Deering, Stephen G.
    Thomson, Rowan M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3373 - 3383
  • [4] A systematic evaluation of the dose-rate constant determined by photon spectrometry for 21 different models of low-energy photon-emitting brachytherapy sources
    Chen, Zhe
    Nath, Ravinder
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (20): : 6089 - 6104
  • [5] A DOSIMETRIC UNCERTAINTY ANALYSIS FOR PHOTON-EMITTING BRACHYTHERAPY SOURCES BY THE AAPM AND GEC-ESTRO
    DeWerd, L.
    Ibbott, G.
    Meigooni, A.
    Mitch, M.
    Rivard, M.
    Stump, K.
    Thomadsen, B.
    Venselaar, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S574 - S574
  • [6] Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources
    Ghorbani, Mahdi
    Salahshour, Fateme
    Haghparast, Abbas
    Moghaddas, Toktam Ahmadi
    Knaup, Courtney
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 54 - 67
  • [7] Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO
    Perez-Calatayud, Jose
    Ballester, Facundo
    Das, Rupak K.
    DeWerd, Larry A.
    Ibbott, Geoffrey S.
    Meigooni, Ali S.
    Ouhib, Zoubir
    Rivard, Mark J.
    Sloboda, Ron S.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2012, 39 (05) : 2904 - 2929
  • [8] Measurements of X-Ray Spectra Emergent From Low-Energy Photon-Emitting Brachytherapy Sources
    Mitch, M.
    Jackson, D.
    Seltzer, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Investigating the Influence of Tissue Geometry On Bioluminescence Imaging for Quantification of Low Photon-Emitting Sources
    Melemenidis, S.
    Graves, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E176 - E176
  • [10] Towards a determination of the absorbed dose to water in water for low-energy photon-emitting brachytherapy seeds
    Schneider, T.
    Lange, B.
    Selbach, H-J
    METROLOGIA, 2007, 44 (05) : 407 - 414