Towards a determination of the absorbed dose to water in water for low-energy photon-emitting brachytherapy seeds

被引:2
|
作者
Schneider, T. [1 ]
Lange, B. [1 ]
Selbach, H-J [1 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
关键词
D O I
10.1088/0026-1394/44/5/018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An accurate determination of the dose produced by brachytherapy seeds emitting low-energy photons is an important component of the radiotherapeutic process. As yet, the output of these seeds has usually been specified in terms of the air kerma rate. The desired quantity in radiation therapy is, however, the absorbed dose to water inside a water phantom, for which primary standards are not available. For this reason, developments are under way in the Physikalisch-Technische Bundesanstalt to establish a primary standard to determine the absorbed dose to water within a phantom. As a fundamental step towards this aim, a method will be introduced in this publication to determine the water kerma inside a graphite phantom housing an extrapolation chamber. Experimental results will be presented and compared with water kerma values obtained from air kerma measurements in free air and applying a conversion factor to water kerma for the conditions of the experiment. First estimates indicate that the relative uncertainty is of the order of 1% (k = 1).
引用
收藏
页码:407 / 414
页数:8
相关论文
共 50 条
  • [1] Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources
    Chen, Zhe Jay
    Nath, Ravinder
    MEDICAL PHYSICS, 2007, 34 (04) : 1412 - 1430
  • [2] Measurements of X-Ray Spectra Emergent From Low-Energy Photon-Emitting Brachytherapy Sources
    Mitch, M.
    Jackson, D.
    Seltzer, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] A systematic evaluation of the dose-rate constant determined by photon spectrometry for 21 different models of low-energy photon-emitting brachytherapy sources
    Chen, Zhe
    Nath, Ravinder
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (20): : 6089 - 6104
  • [4] A robust method for determining the absorbed dose to water in a phantom for low-energy photon radiation
    Schneider, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : 3387 - 3402
  • [5] Model-specific uncertainties in air-kerma strength measurements of low-energy photon-emitting brachytherapy sources
    Mitch, M.
    Seltzer, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2337 - 2337
  • [6] A NEW DEVICE FOR THE MEASUREMENT OF THE ABSORBED DOSE TO WATER FOR LOW-ENERGY X-RAYS AND LOW DOSE-RATE BRACHYTHERAPY SOURCES
    Schneider, T.
    Lange, B.
    Meier, M.
    Selbach, H. J.
    Taegtmeyer, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S480 - S480
  • [7] CONSISTENCY IN THE DETERMINATION OF ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS
    MIJNHEER, B
    MEDICAL PHYSICS, 1986, 13 (05) : 780 - 780
  • [8] Measurement of absorbed dose in water in brachytherapy
    Pawlowski, Piotr
    Szymko, Magdalena
    Wolowiec, Pawel
    Braziewicz, Janusz
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (04):
  • [9] The equivalence of the absorbed dose to water in high energy photon beams
    Stancu, E.
    Kapsch, R-P.
    Badita, E. S.
    Scarlat, F.
    Scarisoreanu, A. M.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2018, 12 (3-4): : 237 - 239
  • [10] A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources
    Sliski, Alan
    Soares, Christopher
    Mitch, Michael G.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 24 - 27