Towards a determination of the absorbed dose to water in water for low-energy photon-emitting brachytherapy seeds

被引:2
|
作者
Schneider, T. [1 ]
Lange, B. [1 ]
Selbach, H-J [1 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
关键词
D O I
10.1088/0026-1394/44/5/018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An accurate determination of the dose produced by brachytherapy seeds emitting low-energy photons is an important component of the radiotherapeutic process. As yet, the output of these seeds has usually been specified in terms of the air kerma rate. The desired quantity in radiation therapy is, however, the absorbed dose to water inside a water phantom, for which primary standards are not available. For this reason, developments are under way in the Physikalisch-Technische Bundesanstalt to establish a primary standard to determine the absorbed dose to water within a phantom. As a fundamental step towards this aim, a method will be introduced in this publication to determine the water kerma inside a graphite phantom housing an extrapolation chamber. Experimental results will be presented and compared with water kerma values obtained from air kerma measurements in free air and applying a conversion factor to water kerma for the conditions of the experiment. First estimates indicate that the relative uncertainty is of the order of 1% (k = 1).
引用
收藏
页码:407 / 414
页数:8
相关论文
共 50 条
  • [31] Transmitted photon spectra of low-energy gamma rays through water
    Swarup, J.
    Peshori, L.H.
    1600, (36):
  • [33] COMPARISON OF THE NMIJ AND THE ARPANSA STANDARDS FOR ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS
    Shimizu, M.
    Morishita, Y.
    Kato, M.
    Tanaka, T.
    Kurosawa, T.
    Takata, N.
    Saito, N.
    Ramanathan, G.
    Harty, P. D.
    Oliver, C.
    Wright, T.
    Butler, D. J.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 181 - 186
  • [34] ASSESSMENT OF ABSORBED DOSE TO WATER IN HIGH ENERGY PHOTON BEAMS USING DIFFERENT CYLINDRICAL CHAMBERS
    Stancu, Elena
    Vancea, Catalin
    Valenta, Jiri
    Zeman, Josef
    Badita, Eugenia
    Scarisoreanu, Anca
    ROMANIAN REPORTS IN PHYSICS, 2015, 67 (02) : 693 - 699
  • [35] Procedures for establishing and maintaining consistent air-kerma strength standards for low-energy, photon-emitting brachytherapy sources: Recommendations of the Calibration Laboratory Accreditation Subcommittee of the American Association of Physicists in Medicine
    DeWerd, LA
    Huq, MS
    Das, IJ
    Ibbott, GS
    Hanson, WF
    Slowey, TW
    Williamson, JF
    Coursey, BM
    MEDICAL PHYSICS, 2004, 31 (03) : 675 - 681
  • [36] General methods for calculating the air kerma rate for clinical dosimetry of low-energy photon emitting brachytherapy sources
    Rivard, M
    Leal, L
    Kirk, B
    MEDICAL PHYSICS, 2002, 29 (06) : 1221 - 1221
  • [37] Implementation of absorbed dose determination based on absorbed dose to water standards in external beam radiotherapy
    Noerrevang, O
    Berg, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S111 - S111
  • [38] Comments on 'Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations'
    Fippel, M
    Nüsslin, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : L17 - L18
  • [39] REALIZATION OF THE ABSORBED DOSE TO WATER FOR I-125 INTERSTITIAL BRACHYTHERAPY SOURCES
    Schneider, T.
    Selbach, H. J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S66 - S66
  • [40] Realisation of the absorbed dose to water for I-125 interstitial brachytherapy sources
    Schneider, Thorsten
    Selbach, Hans-Joachim
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 442 - 445