Integration method of silicon sensors on SU-8-based microfluidic platforms

被引:3
|
作者
Perdigones, Francisco [1 ]
Aracil, Carmen [1 ]
Quero, Jose M. [1 ]
Gutierrez, Manuel [2 ]
Jiménez, Cecilia [2 ]
Giménez, Pablo [2 ]
机构
[1] Escuela Super Ingn, Dept Ingn Elect, Seville, Spain
[2] CSIC, CNM, IMB, Cerdanyola Del Valles 08193, Spain
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2015年 / 21卷 / 01期
关键词
SYSTEM; SU-8; DEVICES; FABRICATION; TECHNOLOGY; CHIPS; GUIDE; PDMS;
D O I
10.1007/s00542-014-2082-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a method of integration of silicon sensors in microfluidic platform is presented. In particular, impedimetric silicon sensors are used to make the proof of concept. These sensors are integrated in a FR4 substrate [component of a printed circuit board (PCB)] where the SU-8 microfluidic circuit is built. In order to generalize the application of this method, standard processes that are typical in the laboratories are used. The material to fabricate those microfluidic circuits is the negative photoresist SU-8. The method of fabrication consists on performing the typical SU-8 process over the silicon chips once they are inserted in the FR4 substrate. This method must provide flatness to avoid irregular microchannels. Also, the proposed process must ensure the insulation of the electric connections to avoid short-circuits when the sample fluid flows through the systems, and bondings robust enough to support a spinning step. In addition, the SU-8 process must be clean enough to keep the capability of measurement of the sensors. This cleanness has been studied using different conductivities of a KCl solution, providing good results. Finally, apart from integrating microfluidic and electronics in the same substrate, this method of integration provides an approach to the optimum between low cost, simplicity and precise measurements thank to the use of inexpensive PCB-based platforms and precise silicon sensors.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 50 条
  • [31] High-Aspect-Ratio SU-8-Based Optofluidic Device for Ammonia Detection in Cell Culture Media
    Dervisevic, Esma
    Voelcker, Nicolas H.
    Risbridger, Gail
    Tuck, Kellie L.
    Cadarso, Victor J.
    ACS SENSORS, 2020, 5 (08) : 2523 - 2529
  • [32] An optical microfluidic platform based on a combination of a novel SU8 multilayer technology, waveguides and photodiodes on silicon
    Ruano, JM
    Aguirregabiria, M
    Arroyo, MT
    Berganzo, J
    Blanco, FJ
    de la Fuente, P
    Castaño, E
    Mayora, K
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 34 - 36
  • [33] SU-8-based Flexible Amperometric Device with IDA Electrodes to Regenerate Redox Species in Small Spaces
    Yusuke Kanno
    Takehito Goto
    Kosuke Ino
    Kumi Y. Inoue
    Yasufumi Takahashi
    Hitoshi Shiku
    Tomokazu Matsue
    Analytical Sciences, 2014, 30 : 305 - 309
  • [34] Analysis of the Structural integrity of SU-8-Based Optofluidic Systems for Small-Molecule Crystallization Studies
    Rodriguez-Ruiz, Isaac
    Llobera, Andreu
    Vila-Planas, Jordi
    Johnson, Donald W.
    Gomez-Morales, Jaime
    Manuel Garcia-Ruiz, Juan
    ANALYTICAL CHEMISTRY, 2013, 85 (20) : 9678 - 9685
  • [35] Soft substrate as a sacrificial layer for fabrication free-standing SU-8-based nanofluidic system
    Li, Xiaojun
    Wang, Xudi
    Jin, Jian
    Li, Xin
    Tian, Yangchao
    Fu, Shaojun
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: DESIGN, MANUFACTURING, AND TESTING OF MICRO- AND NANO-OPTICAL DEVICES AND SYSTEMS, 2010, 7657
  • [36] A SU-8-Based Microfabricated Implantable Inductively Coupled Passive RF Wireless Intraocular Pressure Sensor
    Xue, Ning
    Chang, Sung-Pil
    Lee, Jeong-Bong
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (06) : 1338 - 1346
  • [37] Powerful CRISPR-Based Biosensing Techniques and Their Integration With Microfluidic Platforms
    Chen, Bing
    Li, Ya
    Xu, Feng
    Yang, Xiaonan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [38] Two-Photon Polymerization Lithography and Laser Doppler Vibrometry of a SU-8-Based Suspended Microchannel Resonator
    Accoto, Celso
    Qualtieri, Antonio
    Pisanello, Ferruccio
    Ricciardi, Carlo
    Pirri, Candido Fabrizio
    De Vittorio, Massimo
    Rizzi, Francesco
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2015, 24 (04) : 1038 - 1042
  • [39] Biocompatible SU-8-Based Microprobes for Recording Neural Spike Signals From Regenerated Peripheral Nerve Fibers
    Cho, Sung-Hoon
    Lu, Hong Meng
    Cauller, Lawrence
    Romero-Ortega, Mario I.
    Lee, Jeong-Bong
    Hughes, Gareth A.
    IEEE SENSORS JOURNAL, 2008, 8 (11-12) : 1830 - 1836
  • [40] Micromechanical force sensors based on SU-8 resist
    Jordan, A.
    Buettgenbach, S.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2012, 18 (7-8): : 1095 - 1101