Integration method of silicon sensors on SU-8-based microfluidic platforms

被引:3
|
作者
Perdigones, Francisco [1 ]
Aracil, Carmen [1 ]
Quero, Jose M. [1 ]
Gutierrez, Manuel [2 ]
Jiménez, Cecilia [2 ]
Giménez, Pablo [2 ]
机构
[1] Escuela Super Ingn, Dept Ingn Elect, Seville, Spain
[2] CSIC, CNM, IMB, Cerdanyola Del Valles 08193, Spain
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2015年 / 21卷 / 01期
关键词
SYSTEM; SU-8; DEVICES; FABRICATION; TECHNOLOGY; CHIPS; GUIDE; PDMS;
D O I
10.1007/s00542-014-2082-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a method of integration of silicon sensors in microfluidic platform is presented. In particular, impedimetric silicon sensors are used to make the proof of concept. These sensors are integrated in a FR4 substrate [component of a printed circuit board (PCB)] where the SU-8 microfluidic circuit is built. In order to generalize the application of this method, standard processes that are typical in the laboratories are used. The material to fabricate those microfluidic circuits is the negative photoresist SU-8. The method of fabrication consists on performing the typical SU-8 process over the silicon chips once they are inserted in the FR4 substrate. This method must provide flatness to avoid irregular microchannels. Also, the proposed process must ensure the insulation of the electric connections to avoid short-circuits when the sample fluid flows through the systems, and bondings robust enough to support a spinning step. In addition, the SU-8 process must be clean enough to keep the capability of measurement of the sensors. This cleanness has been studied using different conductivities of a KCl solution, providing good results. Finally, apart from integrating microfluidic and electronics in the same substrate, this method of integration provides an approach to the optimum between low cost, simplicity and precise measurements thank to the use of inexpensive PCB-based platforms and precise silicon sensors.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 50 条
  • [21] A SU-8-Based Fully Integrated Biocompatible Inductively Powered Wireless Neurostimulator
    Cho, Sung-Hoon
    Xue, Ning
    Cauller, Lawrence
    Rosellini, Will
    Lee, Jeong-Bong
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2013, 22 (01) : 170 - 176
  • [22] An SU-8-based microprobe with a nanostructured surface enhances neuronal cell attachment and growth
    Kim E.
    Kim J.-Y.
    Choi H.
    Micro and Nano Systems Letters, 5 (1)
  • [23] Highly Integrable Pressurized Microvalve for Portable SU-8 Microfluidic Platforms
    Perdigones, Francisco
    Aracil, Carmen
    Moreno, Jose M.
    Luque, Antonio
    Quero, Jose M.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2014, 23 (02) : 398 - 405
  • [24] Fabrication and characterization of SU-8-based capacitive micromachined ultrasonic transducer for airborne applications
    Joseph, Jose
    Singh, Shiv Govind
    Vanjari, Siva Rama Krishna
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2018, 17 (01):
  • [25] On comparison of the temperature sensitivity of SU-8-based triple-arm MZI against straight rib optical waveguides patterned on silicon wafer
    I. S. Amiri
    M. M. Ariannejad
    M. Ghasemi
    A. Dehzangi
    H. Ahmad
    P. Yupapin
    Indian Journal of Physics, 2019, 93 : 385 - 391
  • [26] On comparison of the temperature sensitivity of SU-8-based triple-arm MZI against straight rib optical waveguides patterned on silicon wafer
    Amiri, I. S.
    Ariannejad, M. M.
    Ghasemi, M.
    Dehzangi, A.
    Ahmad, H.
    Yupapin, P.
    INDIAN JOURNAL OF PHYSICS, 2019, 93 (03) : 385 - 391
  • [27] Simulation, Fabrication, and Characterization of a Sensitive SU-8-Based Fabry-Perot MOEMS Accelerometer
    Taghavi, Majid
    Latifi, Hamid
    Parsanasab, Gholam Mohammad
    Abedi, Abolfazl
    Nikbakht, Hamed
    Sharifi, Mohammad Javad
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2019, 37 (09) : 1893 - 1902
  • [28] A SU-8-Based Compact Implantable Wireless Pressure Sensor for Intraocular Pressure Sensing Application
    Xue, Ning
    Chang, Sung Pil
    Lee, Jeong-Bong
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2854 - 2857
  • [29] Stiffness controlled SU-8-based nanocomposites: application for 1 GHz matching layer conception
    Wang, S. -X.
    Carlier, J.
    Ndieguene, A.
    Campistron, P.
    Debavelaere, D. C.
    Soyet, C.
    Nongaillard, B.
    Zhao, X. -Z.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 678 - +
  • [30] SU-8-based Flexible Amperometric Device with IDA Electrodes to Regenerate Redox Species in Small Spaces
    Kanno, Yusuke
    Goto, Takehito
    Ino, Kosuke
    Inoue, Kumi Y.
    Takahashi, Yasufumi
    Shiku, Hitoshi
    Matsue, Tomokazu
    ANALYTICAL SCIENCES, 2014, 30 (02) : 305 - 309