Reduction of Intravenous Contrast Related Artifacts in CT-Based Attenuation Corrected PET Images

被引:0
|
作者
Ay, M. R. [1 ,2 ]
Bidgholi, J. H. [2 ,5 ]
Ghafarian, P. [2 ,3 ]
Zaidi, H. [4 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Shahid Beheshti Univ, Dept Radiat Med, Tehran, Iran
[4] Univ Hosp Geneva, Div Nucl Med, Geneva, Switzerland
[5] East Tehran Azad Univ, Dept Elect & Comp Engn, Tehran, Iran
来源
4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING | 2009年 / 22卷 / 1-3期
基金
瑞士国家科学基金会;
关键词
Intravenous; Contrast medium; Attenuation Correction; CT; PET;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A well established advantage of using contrast-enhanced CT in dual-modality PET/CT imaging is the possibility to obtain diagnostic quality CT images, thus allowing to increase patient throughput and reduce patient absorbed dose. However, the use of CT data following intravenous (IV) injection of contrast media for attenuation correction might bias the attenuation-map (mu map) and generate visible artifacts on reconstructed PET images owing to the misclassification of contrast-medium with high density bone when using standard procedures for conversion of CT numbers to linear attenuation coefficients at 511 keV. In this study, an algorithm for segmentation and classification of irregular shapes of regions containing IV contrast-medium usually found in clinical CT images is proposed and assessed using clinical data. The proposed automated three-dimensional segmentation method consists of two steps: firstly all objects with high CT number are segmented based on a region-based segmentation method in conjunction with boundary-based segmentation to reduce mis-segmentation of objects. Second, the process of object classification to separate bones and contrast-medium is carried out using a fuzzy classifier as knowledge based nonlinear classifier. Thereafter, either the CT numbers of pixels belonging to the regions segmented as contrast medium are substituted with their equivalent effective bone CT numbers based on segmented contrast correction (SCC) algorithm, or the classified regions as contrast medium can be converted to mu map using different calibration curves for energy mapping. The generated CT images were down-sampled followed by Gaussian smoothing to match the resolution of PET images. The bi-linear calibration curve was used to convert CT pixel values in HU to mu map at 511 keV. The visual assessment of segmented regions in clinical CT images by an experienced radiologist confirmed the accuracy of the algorithm for delineation of contrast enhanced regions. The results illustrate the difference between attenuation coefficients in the generated attenuation maps before and after SCC. Quantitative analysis of the generated mu maps from a clinical study showed an overestimation of 23.4% of attenuation coefficients in the 3D regions classified as contrast-medium. The algorithm is being refined and further validated in clinical setting to enable the application of this algorithm in PET/CT clinical arena.
引用
收藏
页码:513 / 516
页数:4
相关论文
共 50 条
  • [41] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Medhat M. Osman
    Christian Cohade
    Yuji Nakamoto
    Richard L. Wahl
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 603 - 606
  • [42] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.
    Osman, MM
    Cohade, C
    Wahl, RL
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 305P - 305P
  • [43] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Osman, MM
    Cohade, C
    Nakamoto, Y
    Wahl, RL
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 603 - 606
  • [44] The effect of different chemoembolization materials on CT-based attenuation correction in PET/CT
    Heusner, T. -A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Forsting, M.
    Bockisch, A.
    Antoch, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (11): : 1159 - 1165
  • [45] CT-based attenuation correction on the FLEX Triumph™ preclinical PET/CT scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3357 - +
  • [46] CT-Based Attenuation Correction on the FLEX Triumph Preclinical PET/CT Scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 66 - 75
  • [47] Intravenous contrast-enhanced CT can be used for CT-based attenuation correction in clinical 111In-octreotide SPECT/CT
    Klausen T.L.
    Mortensen J.
    de Nijs R.
    Andersen F.L.
    Højgaard L.
    Beyer T.
    Holm S.
    EJNMMI Physics, 2 (1) : 1 - 13
  • [48] Non Attenuation Corrected Versus Body Attenuation Corrected PET/CT and PET Data in Lung Cancer
    Houzard, C.
    Ksyar, R.
    Maintas, C.
    Scheiber, C.
    Itti, R.
    Maintas, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S144 - S144
  • [49] Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 2009,
  • [50] Metal Artifact Reduction in CT-Based Attenuation Correction of PET Data Using the Virtual Sinogram Concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1848 - +