Reduction of Intravenous Contrast Related Artifacts in CT-Based Attenuation Corrected PET Images

被引:0
|
作者
Ay, M. R. [1 ,2 ]
Bidgholi, J. H. [2 ,5 ]
Ghafarian, P. [2 ,3 ]
Zaidi, H. [4 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Shahid Beheshti Univ, Dept Radiat Med, Tehran, Iran
[4] Univ Hosp Geneva, Div Nucl Med, Geneva, Switzerland
[5] East Tehran Azad Univ, Dept Elect & Comp Engn, Tehran, Iran
来源
4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING | 2009年 / 22卷 / 1-3期
基金
瑞士国家科学基金会;
关键词
Intravenous; Contrast medium; Attenuation Correction; CT; PET;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A well established advantage of using contrast-enhanced CT in dual-modality PET/CT imaging is the possibility to obtain diagnostic quality CT images, thus allowing to increase patient throughput and reduce patient absorbed dose. However, the use of CT data following intravenous (IV) injection of contrast media for attenuation correction might bias the attenuation-map (mu map) and generate visible artifacts on reconstructed PET images owing to the misclassification of contrast-medium with high density bone when using standard procedures for conversion of CT numbers to linear attenuation coefficients at 511 keV. In this study, an algorithm for segmentation and classification of irregular shapes of regions containing IV contrast-medium usually found in clinical CT images is proposed and assessed using clinical data. The proposed automated three-dimensional segmentation method consists of two steps: firstly all objects with high CT number are segmented based on a region-based segmentation method in conjunction with boundary-based segmentation to reduce mis-segmentation of objects. Second, the process of object classification to separate bones and contrast-medium is carried out using a fuzzy classifier as knowledge based nonlinear classifier. Thereafter, either the CT numbers of pixels belonging to the regions segmented as contrast medium are substituted with their equivalent effective bone CT numbers based on segmented contrast correction (SCC) algorithm, or the classified regions as contrast medium can be converted to mu map using different calibration curves for energy mapping. The generated CT images were down-sampled followed by Gaussian smoothing to match the resolution of PET images. The bi-linear calibration curve was used to convert CT pixel values in HU to mu map at 511 keV. The visual assessment of segmented regions in clinical CT images by an experienced radiologist confirmed the accuracy of the algorithm for delineation of contrast enhanced regions. The results illustrate the difference between attenuation coefficients in the generated attenuation maps before and after SCC. Quantitative analysis of the generated mu maps from a clinical study showed an overestimation of 23.4% of attenuation coefficients in the 3D regions classified as contrast-medium. The algorithm is being refined and further validated in clinical setting to enable the application of this algorithm in PET/CT clinical arena.
引用
收藏
页码:513 / 516
页数:4
相关论文
共 50 条
  • [21] PET recognition of pulmonary metastases on PET/CT imaging: impact of attenuation-corrected and non-attenuation-corrected PET images
    Reinhardt, MJ
    Wiethoelter, N
    Matthies, A
    Joe, AY
    Strunk, H
    Jaeger, U
    Biersack, HJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (02) : 134 - 139
  • [22] Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties
    Kim, Soo Mee
    Alessio, Adam M.
    De Man, Bruno
    Asma, Evren
    Kinahan, Paul E.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [23] Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid
    Mehrsima Abdoli
    Johan R. de Jong
    Jan Pruim
    Rudi A. J. O. Dierckx
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 2257 - 2268
  • [24] Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid
    Abdoli, Mehrsima
    de Jong, Johan R.
    Pruim, Jan
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (12) : 2257 - 2268
  • [25] Direct Reconstruction of CT-Based Attenuation Correction Images for PET With Cluster-Based Penalties
    Kim, Soo Mee
    Alessio, Adam M.
    De Man, Bruno
    Kinahan, Paul E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (03) : 959 - 968
  • [26] Differences between MRI and external CT derived attenuation corrected PET images obtained on PET/MRI system in presence of metallic artifacts
    Knesaurek, Karin
    Izauierdo-Garcia, David
    Machae, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [27] Contrast artifact correction in CT-based attenuation correction
    Chen, T.
    Lin, H. H.
    Chuang, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S285
  • [28] Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents.
    Beyer, T
    Townsend, DW
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 56P - 56P
  • [29] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [30] Effect of different Chemoembolization materials on CT-based PET attenuation correction in PET/CT
    Heusner, T. A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Bockisch, A.
    Antoch, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S151 - S151