Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study

被引:45
|
作者
Lee, Kyoung Sub [1 ]
Sung, Kyung Rim [1 ]
Kang, Sung Yong [1 ]
Cho, Jung Woo [1 ]
Kim, Dong Yoon [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Ophthalmol, Seoul 138736, South Korea
关键词
Anterior segment OCT; Anterior chamber angle; Laser peripheral iridotomy; FIBER LAYER THICKNESS; ASIAN EYES; GLAUCOMA; POPULATION; PREVALENCE; GONIOSCOPY; DEPTH;
D O I
10.1007/s10384-011-0009-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To study quantitative changes in anterior chamber angle (ACA) after laser peripheral iridotomy (LPI) in narrow-angle eyes using anterior segment optical coherence tomography (AS-OCT). Eighteen subjects with narrow angles were imaged with AS-OCT for determining test-retest variability. Forty-six participants with narrow angles were scanned with AS-OCT before LPI and 4 weeks after LPI. The presence of ACA closure by both AS-OCT imaging and gonioscopy was compared before and after LPI. Three ACA parameters by AS-OCT, angle opening distance at 500 mu m (AOD(500)), trabecular-ris space area at 500 mu m (TISA(500)) and angle recess area at 500 mu m (ARA(500)), at both nasal and temporal quadrants were incorporated for analysis. The increment of ACA parameters defined as exceeding the 95% confidence interval of test-retest variability was assessed after LPI. All 3 parameters obtained from the 18 eyes showed good measurement reproducibility (intraclass correlation coefficient 0.850-0.979). Persistent angle closure was detected in 23.9% of eyes by gonioscopy, and in 34.8% of eyes by AS-OCT images at temporal quadrant after LPI. When assessed by measurement variability criteria, the percentage of eyes that showed no significant change in ACA parameters ranged from 23.9% to 45.7% after LPI. Overall, ACA parameters changed significantly after LPI; however, when assessed by AS-OCT, ACA remained unchanged in some narrow-angle eyes despite LPI. Our findings suggest that multiple causes other than pupillary block may contribute to narrow-angle closure following LPI.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [31] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [32] Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes
    Nolan, Winifred P.
    See, Jovina L.
    Chew, Paul T. K.
    Friedman, David S.
    Smith, Scott D.
    Radhakrishnan, Sunita
    Zheng, Ce
    Foster, Paul J.
    Aung, Tin
    OPHTHALMOLOGY, 2007, 114 (01) : 33 - 39
  • [33] Anterior segment optical coherence tomography in subtypes of angle closure glaucoma
    Nouri-Mahdavi, Kouros
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 159 - 160
  • [34] Anterior segment optical coherence tomography of acute primary angle closure
    Zhang, Hai Tao
    Xu, Liang
    Cao, Wei Fang
    Wang, Ya Xing
    Jonas, Jost B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 825 - 831
  • [35] Influence of Anterior Segment Biometric Parameters on the Anterior Chamber Angle Width in Eyes With Angle Closure
    Matsuki, Takaaki
    Hirose, Fumitaka
    Ito, Shin-ichiro
    Hata, Masayuki
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    JOURNAL OF GLAUCOMA, 2015, 24 (02) : 144 - 148
  • [36] Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography
    Liu, Lance
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 614 - 622
  • [37] Anterior segment optical coherence tomography of acute primary angle closure
    Hai Tao Zhang
    Liang Xu
    Wei Fang Cao
    Ya Xing Wang
    Jost B. Jonas
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 825 - 831
  • [38] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    Mansouri, K.
    Sommerhalder, J.
    Shaarawy, T.
    EYE, 2010, 24 (02) : 233 - 239
  • [39] Reproducibility of Anterior Chamber Angle Measurements With Anterior Segment Coherence Tomography
    De Brabander, J.
    Tan, A. N.
    Berendschot, T. T. J. M.
    Sauren, L. D. C.
    Nekeman, D.
    Passos, V. Lima
    Webers, C. A. B.
    Beckers, H. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    K Mansouri
    J Sommerhalder
    T Shaarawy
    Eye, 2010, 24 : 233 - 239