Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study

被引:45
|
作者
Lee, Kyoung Sub [1 ]
Sung, Kyung Rim [1 ]
Kang, Sung Yong [1 ]
Cho, Jung Woo [1 ]
Kim, Dong Yoon [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Ophthalmol, Seoul 138736, South Korea
关键词
Anterior segment OCT; Anterior chamber angle; Laser peripheral iridotomy; FIBER LAYER THICKNESS; ASIAN EYES; GLAUCOMA; POPULATION; PREVALENCE; GONIOSCOPY; DEPTH;
D O I
10.1007/s10384-011-0009-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To study quantitative changes in anterior chamber angle (ACA) after laser peripheral iridotomy (LPI) in narrow-angle eyes using anterior segment optical coherence tomography (AS-OCT). Eighteen subjects with narrow angles were imaged with AS-OCT for determining test-retest variability. Forty-six participants with narrow angles were scanned with AS-OCT before LPI and 4 weeks after LPI. The presence of ACA closure by both AS-OCT imaging and gonioscopy was compared before and after LPI. Three ACA parameters by AS-OCT, angle opening distance at 500 mu m (AOD(500)), trabecular-ris space area at 500 mu m (TISA(500)) and angle recess area at 500 mu m (ARA(500)), at both nasal and temporal quadrants were incorporated for analysis. The increment of ACA parameters defined as exceeding the 95% confidence interval of test-retest variability was assessed after LPI. All 3 parameters obtained from the 18 eyes showed good measurement reproducibility (intraclass correlation coefficient 0.850-0.979). Persistent angle closure was detected in 23.9% of eyes by gonioscopy, and in 34.8% of eyes by AS-OCT images at temporal quadrant after LPI. When assessed by measurement variability criteria, the percentage of eyes that showed no significant change in ACA parameters ranged from 23.9% to 45.7% after LPI. Overall, ACA parameters changed significantly after LPI; however, when assessed by AS-OCT, ACA remained unchanged in some narrow-angle eyes despite LPI. Our findings suggest that multiple causes other than pupillary block may contribute to narrow-angle closure following LPI.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [21] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [22] Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography
    Moghimi, Sasan
    Zandvakil, Narges
    Vahedian, Zakieh
    Mohammadi, Massood
    Fakhraie, Ghasem
    Coleman, Anne L.
    Lin, Shan C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07): : 615 - 622
  • [23] Anterior segment optical coherence tomography imaging of a laser peripheral iridotomy
    Ouederni, M.
    Maamouri, R.
    Sassi, H.
    Nefaa, F.
    Cheour, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (05): : 772 - 773
  • [24] Changes in Anterior Segment Morphology after Laser Peripheral Iridotomy: An Anterior Segment Optical Coherence Tomography Study
    How, Alicia C.
    Baskaran, Mani
    Kumar, Rajesh S.
    He, Mingguang
    Foster, Paul J.
    Lavanya, Raghavan
    Wong, Hon-Tym
    Chew, Paul T. K.
    Friedman, David S.
    Aung, Tin
    OPHTHALMOLOGY, 2012, 119 (07)
  • [25] Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes
    Moghimi, Sasan
    Ramezani, Farshid
    He, Mingguang
    Coleman, Anne L.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 7611 - 7617
  • [26] Assessment of the Anterior Chamber Angle in Patients with Nanophthalmos: An Anterior Segment Optical Coherence Tomography Study
    Kara, Necip
    Baz, Okkes
    Altinkaynak, Hasan
    Altan, Cigdem
    Demirok, Ahmet
    CURRENT EYE RESEARCH, 2013, 38 (05) : 563 - 568
  • [27] Factors Influencing Laser Peripheral Iridotomy Outcomes in White Eyes An Anterior Segment Optical Coherence Tomography Study
    Ang, Ghee Soon
    Wells, Anthony P.
    JOURNAL OF GLAUCOMA, 2011, 20 (09) : 577 - 583
  • [28] Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
    Liu, Lance
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (12) : 1682 - 1686
  • [29] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [30] Effect of Hemodialysis on Anterior Chamber Angle Measured by Anterior Segment Optical Coherence Tomography
    Shin, Yong Un
    Kim, Ji Hong
    Cho, Heeyoon
    Kim, Dae Sung
    Yi, Joo-Hark
    Han, Sang-Woong
    Seong, Mincheol
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019