Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study

被引:45
|
作者
Lee, Kyoung Sub [1 ]
Sung, Kyung Rim [1 ]
Kang, Sung Yong [1 ]
Cho, Jung Woo [1 ]
Kim, Dong Yoon [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Ophthalmol, Seoul 138736, South Korea
关键词
Anterior segment OCT; Anterior chamber angle; Laser peripheral iridotomy; FIBER LAYER THICKNESS; ASIAN EYES; GLAUCOMA; POPULATION; PREVALENCE; GONIOSCOPY; DEPTH;
D O I
10.1007/s10384-011-0009-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To study quantitative changes in anterior chamber angle (ACA) after laser peripheral iridotomy (LPI) in narrow-angle eyes using anterior segment optical coherence tomography (AS-OCT). Eighteen subjects with narrow angles were imaged with AS-OCT for determining test-retest variability. Forty-six participants with narrow angles were scanned with AS-OCT before LPI and 4 weeks after LPI. The presence of ACA closure by both AS-OCT imaging and gonioscopy was compared before and after LPI. Three ACA parameters by AS-OCT, angle opening distance at 500 mu m (AOD(500)), trabecular-ris space area at 500 mu m (TISA(500)) and angle recess area at 500 mu m (ARA(500)), at both nasal and temporal quadrants were incorporated for analysis. The increment of ACA parameters defined as exceeding the 95% confidence interval of test-retest variability was assessed after LPI. All 3 parameters obtained from the 18 eyes showed good measurement reproducibility (intraclass correlation coefficient 0.850-0.979). Persistent angle closure was detected in 23.9% of eyes by gonioscopy, and in 34.8% of eyes by AS-OCT images at temporal quadrant after LPI. When assessed by measurement variability criteria, the percentage of eyes that showed no significant change in ACA parameters ranged from 23.9% to 45.7% after LPI. Overall, ACA parameters changed significantly after LPI; however, when assessed by AS-OCT, ACA remained unchanged in some narrow-angle eyes despite LPI. Our findings suggest that multiple causes other than pupillary block may contribute to narrow-angle closure following LPI.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [1] Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study
    Kyoung Sub Lee
    Kyung Rim Sung
    Sung Yong Kang
    Jung Woo Cho
    Dong Yoon Kim
    Michael S. Kook
    Japanese Journal of Ophthalmology, 2011, 55 : 213 - 219
  • [2] Comparing Laser Peripheral Iridotomy to Cataract Extraction in Narrow Angle Eyes Using Anterior Segment Optical Coherence Tomography
    Melese, Ephrem
    Peterson, Jeffrey R.
    Feldman, Robert M.
    Baker, Laura A.
    Bell, Nicholas P.
    Chuang, Alice Z.
    Blieden, Lauren S.
    PLOS ONE, 2016, 11 (09):
  • [3] Predicting the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes using Anterior Segment Optical Coherence Tomography
    Koh, Victor T. C.
    Keshtkaran, Muhammad Reza
    Chew, Paul Tec Kuan
    Aquino, Maria Cecilia D.
    Sng, Chelvin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [4] Predicting the outcome of laser peripheral iridotomy for primary angle closure suspect eyes using anterior segment optical coherence tomography
    Koh, Victor
    Keshtkaran, Mohammad Reza
    Hernstadt, David
    Aquino, Maria Cecilia D.
    Chew, Paul T.
    Sng, Chelvin
    ACTA OPHTHALMOLOGICA, 2019, 97 (01) : E57 - E63
  • [5] Comparing the Effect of Laser Peripheral Iridotomy to Lens Extraction on Anterior Segment Morphology in Narrow Angle Eyes using Anterior Segment Optical Coherence Tomography (ASOCT)
    Gross, Jacob
    Baker, Laura
    Chuang, Alice
    Blieden, Lauren S.
    Bell, Nicholas P.
    Feldman, Robert M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [7] Quantitative analysis of anterior chamber following peripheral laser iridotomy using Pentacam in eyes with primary angle closure
    Jain, Rajeev
    Grewal, Dilraj
    Grewal, Satinder Pal Singh
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (01) : 55 - 60
  • [8] Outcomes of Laser Peripheral Iridotomy in Angle Closure Subgroups According to Anterior Segment Optical Coherence Tomography Parameters
    Han, Seungbong
    Sung, Kyung Rim
    Lee, Kyoung Sub
    Hong, Ji Wook
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6795 - 6801
  • [9] Anatomic Predictors for Anterior Chamber Angle Opening After Laser Peripheral Iridotomy in Narrow Angle Eyes
    Huang, Guofu
    Gonzalez, Eduardo
    Lee, Roland
    Osmonavic, Senad
    Leeungurasatien, Thidarat
    He, Mingguang
    Lin, Shan C.
    CURRENT EYE RESEARCH, 2012, 37 (07) : 575 - 582
  • [10] Anterior segment optical coherence tomography for imaging the anterior chamber after laser peripheral iridotomy
    Memarzadeh, Farnaz
    Li, Yan
    Chopra, Vikas
    Varma, Rohit
    Francis, Brian A.
    Huang, David
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (05) : 877 - 879