Experimental investigation of an integrated absorption- solid desiccant air conditioning system

被引:17
|
作者
Ali, Muzaffar [1 ]
Habib, Muhammad Farhan [1 ]
Sheikh, Nadeem Ahmed [2 ]
Akhter, Javed [3 ]
Gilani, Syed Ihtsham ul Haq [4 ]
机构
[1] Univ Engn & Technol, Mech Engn Dept, Taxila, Pakistan
[2] Int Islamic Univ, Fac Engn & Technol, Mech Engn Dept, Islamabad, Pakistan
[3] Univ Chakwal, Dept Mechatron Engn, Chakwal, Punjab, Pakistan
[4] Univ Teknol PETRONAS, Mech Engn Dept, Seri Iskandar 32610, Perak, Malaysia
关键词
Integrated system; Solid desiccant; Dehumidification; Thermal load; Absorption system; COOLING SYSTEM; SOLAR-ENERGY; HYBRID; PERFORMANCE; HOT; REFRIGERATION;
D O I
10.1016/j.applthermaleng.2021.117912
中图分类号
O414.1 [热力学];
学科分类号
摘要
Separate handling of sensible and latent components of building loads can be an energy efficient approach compared to simultaneous management of both. This paper presents a detailed experimental analysis of an energy efficient air conditioning system using solid desiccant integrated with absorption system for separate building thermal load handling. The experimental system consists of silica-gel based solid desiccant for latent load handling, whereas the gas fired air-cooled NH3-H2O absorption chiller is used to handle sensible load of the space. A chilled water-cooling coil heat exchanger is installed on the process side of desiccant cooling system to integrate it with the absorption chiller. The performance of integrated absorption- solid desiccant system is compared with a standalone conventional desiccant air conditioning system with a direct evaporative cooler considering it as baseline system under wide range of operating conditions including air temperature, air humidity, and regeneration temperature. The comparative analysis is performed in terms of supply air temperature, cooling capacity, and coefficient of performance. The experimental results exhibit that supply air temperature of the integrated system is 15.2 degrees C compared to 24.6 degrees C achieved by conventional desiccant system. Moreover, COPth of the integrated system is also 50-55% higher than its counterpart and it is almost comparable with double-effect absorption chiller. It is concluded that the integrated system using separate load management approach is more efficient for HVAC applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [2] ANALYSIS OF AN INTEGRATED ABSORPTION LIQUID DESICCANT AIR-CONDITIONING SYSTEM
    GARI, HA
    ALY, SE
    FATHALAH, KA
    HEAT RECOVERY SYSTEMS & CHP, 1990, 10 (02): : 87 - 98
  • [3] Experimental investigation on desiccant air-conditioning system in India
    Mittal V.
    Khan B.K.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (2): : 161 - 165
  • [4] Performance investigation on solid desiccant assisted mobile air conditioning system
    Lee, Hoseong
    Lin, Xiaojie
    Hwang, Yunho
    Radermacher, Reinhard
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1370 - 1380
  • [5] Theoretical and experimental investigation of the performance of a desiccant air-conditioning system
    Panaras, G.
    Mathioulakis, E.
    Belessiotis, V.
    Kyriakis, N.
    RENEWABLE ENERGY, 2010, 35 (07) : 1368 - 1375
  • [6] An experimental study of a novel integrated desiccant air conditioning system for building applications
    Elmer, Theo
    Worall, Mark
    Wu, Shenyi
    Riffat, Saffa
    ENERGY AND BUILDINGS, 2016, 111 : 434 - 445
  • [7] Experimental investigation of a novel configuration of desiccant based evaporative air conditioning system
    Uckan, Irfan
    Yilmaz, Tuncay
    Hurdogan, Ertac
    Buyukalaca, Orhan
    ENERGY CONVERSION AND MANAGEMENT, 2013, 65 : 606 - 615
  • [8] Solid desiccant air conditioning system using desiccant dehumidifiers with cooling technique and thermal recovery unit: Experimental investigation and performance analysis
    Abdelgaied, Mohamed
    Saber, Mohamed A.
    Bassuoni, M. M.
    Khaira, Ahmad M.
    JOURNAL OF CLEANER PRODUCTION, 2023, 421
  • [9] Experimental investigation of a ground-coupled desiccant assisted air conditioning system
    Speerforck, Arne
    Schmitz, Gerhard
    APPLIED ENERGY, 2016, 181 : 575 - 585
  • [10] Experimental and numerical investigation to optimise liquid desiccant system for advanced air conditioning
    Shivaprasad, K. V.
    Roy, Sumit
    Giampieri, Alessandro
    Smallbone, Andrew
    Roskilly, Anthony Paul
    SCIENTIFIC REPORTS, 2025, 15 (01):