Experimental investigation of an integrated absorption- solid desiccant air conditioning system

被引:17
|
作者
Ali, Muzaffar [1 ]
Habib, Muhammad Farhan [1 ]
Sheikh, Nadeem Ahmed [2 ]
Akhter, Javed [3 ]
Gilani, Syed Ihtsham ul Haq [4 ]
机构
[1] Univ Engn & Technol, Mech Engn Dept, Taxila, Pakistan
[2] Int Islamic Univ, Fac Engn & Technol, Mech Engn Dept, Islamabad, Pakistan
[3] Univ Chakwal, Dept Mechatron Engn, Chakwal, Punjab, Pakistan
[4] Univ Teknol PETRONAS, Mech Engn Dept, Seri Iskandar 32610, Perak, Malaysia
关键词
Integrated system; Solid desiccant; Dehumidification; Thermal load; Absorption system; COOLING SYSTEM; SOLAR-ENERGY; HYBRID; PERFORMANCE; HOT; REFRIGERATION;
D O I
10.1016/j.applthermaleng.2021.117912
中图分类号
O414.1 [热力学];
学科分类号
摘要
Separate handling of sensible and latent components of building loads can be an energy efficient approach compared to simultaneous management of both. This paper presents a detailed experimental analysis of an energy efficient air conditioning system using solid desiccant integrated with absorption system for separate building thermal load handling. The experimental system consists of silica-gel based solid desiccant for latent load handling, whereas the gas fired air-cooled NH3-H2O absorption chiller is used to handle sensible load of the space. A chilled water-cooling coil heat exchanger is installed on the process side of desiccant cooling system to integrate it with the absorption chiller. The performance of integrated absorption- solid desiccant system is compared with a standalone conventional desiccant air conditioning system with a direct evaporative cooler considering it as baseline system under wide range of operating conditions including air temperature, air humidity, and regeneration temperature. The comparative analysis is performed in terms of supply air temperature, cooling capacity, and coefficient of performance. The experimental results exhibit that supply air temperature of the integrated system is 15.2 degrees C compared to 24.6 degrees C achieved by conventional desiccant system. Moreover, COPth of the integrated system is also 50-55% higher than its counterpart and it is almost comparable with double-effect absorption chiller. It is concluded that the integrated system using separate load management approach is more efficient for HVAC applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental investigation on air dehumidification performance of metal organic frameworks and its application potential for solid desiccant air conditioning systems
    Nie, Jinzhe
    Pang, Yuxin
    Liu, Jilei
    Kong, Xiangrui
    Zhang, Han
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (02) : 230 - 240
  • [32] Experimental investigation on solar powered desiccant coated heat exchanger humidification air conditioning system in winter
    Zhang, J. Y.
    Ge, T. S.
    Dai, Y. J.
    Zhao, Y.
    Wang, R. Z.
    ENERGY, 2017, 137 : 468 - 478
  • [33] COMBINED ABSORPTION-DESICCANT SOLAR POWERED AIR CONDITIONING SYSTEM.
    Aly, S.E.
    Fathalah, K.A.
    Warme- und Stoffubertragung Zeitschrift, 1988, 23 (02): : 111 - 121
  • [34] COMBINED ABSORPTION-DESICCANT SOLAR POWERED AIR-CONDITIONING SYSTEM
    ALY, SE
    FATHALAH, KA
    WARME UND STOFFUBERTRAGUNG-THERMO AND FLUID DYNAMICS, 1988, 23 (02): : 111 - 121
  • [35] An experimental study on multi-purpose desiccant integrated vapor-compression air-conditioning system
    Khalil, Alsaied
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (04) : 535 - 544
  • [36] Adsorption air conditioning: a comprehensive review in desiccant materials, system progress, and recent studies on different configurations of hybrid solid desiccant air conditioning systems
    Mohamed Abdelgaied
    Mohamed A. Saber
    Mohamed Mahgoub Bassuoni
    Ahmed M. Khaira
    Environmental Science and Pollution Research, 2023, 30 : 28344 - 28372
  • [37] Adsorption air conditioning: a comprehensive review in desiccant materials, system progress, and recent studies on different configurations of hybrid solid desiccant air conditioning systems
    Abdelgaied, Mohamed
    Saber, Mohamed A.
    Bassuoni, Mohamed Mahgoub
    Khaira, Ahmed M.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (11) : 28344 - 28372
  • [38] Investigation of solar energy utilization in a novel desiccant based air conditioning system
    Hurdogan, Ertac
    Buyukalaca, Orhan
    Yilmaz, Tuncay
    Hepbasli, Arif
    Uckan, Irfan
    ENERGY AND BUILDINGS, 2012, 55 : 757 - 764
  • [39] An overview of solid desiccant dehumidification and air conditioning systems
    Sultan, Muhammad
    El-Sharkawy, Ibrahim I.
    Miyazaki, Takahiko
    Saha, Bidyut Baran
    Koyama, Shigeru
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 46 : 16 - 29
  • [40] Solid desiccant air conditioning - A state of the art review
    Jani, D. B.
    Mishra, Manish
    Sahoo, P. K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 : 1451 - 1469