ANALYSIS OF AN INTEGRATED ABSORPTION LIQUID DESICCANT AIR-CONDITIONING SYSTEM

被引:4
|
作者
GARI, HA
ALY, SE
FATHALAH, KA
机构
[1] Thermal Engineering Department, King Abdulaziz University, P.O. Box 9027
来源
HEAT RECOVERY SYSTEMS & CHP | 1990年 / 10卷 / 02期
关键词
D O I
10.1016/0890-4332(90)90163-E
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an analysis of an integrated absorption cooling machine with a water heat-driven liquid desiccant dehumidifier for air conditioning systems. The waste heat recovery unit operates between the condenser of the absorption machine and the liquid absorbent regenerator. A mathematic model for the liquid desiccant unit is described and the governing equations are solved. The model is applied to the dehumidifying chamber (DHC) and the regeneration chamber (RGC) in a coupled mode. Results showed that the cooling water temperature and the transfer potentials are the controlling factors affecting the DHC while the mass transfer potential and the absorbent air mass ratio are dominant in the RGC. For a 42°C/31°C DBT/WBT outside air, the integrated system has an estimated overall COP of 1.21 for a supply of hot water at 140°C fed to the generator and a cooling water supply at 30°C. This COP is 50% higher than the COP for the absorption chiller alone (0.81). The overall COP is higher than that for a double effect absorption machine if the outside air conditions and the cooling water effects are taken into consideration. Moreover, a LiBr-H2O solution is used at both ends of the system, which would reflect some savings in both capital and running cost of the air conditioning unit. © 1990.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 50 条
  • [1] Performance Analysis of Hybrid Air-Conditioning System with Integrated Liquid Desiccant Dehumidification
    Zhang, Li
    Hihara, Eiji
    Dang, Chaobin
    [J]. ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 535 - 540
  • [2] Performance analysis of a combined desiccant/absorption air-conditioning system
    Schinner, EN
    Radermacher, R
    [J]. HVAC&R RESEARCH, 1999, 5 (01): : 77 - 84
  • [3] Performance analysis of a membrane liquid desiccant air-conditioning system
    Abdel-Salam, Ahmed H.
    Ge, Gaoming
    Simonson, Carey J.
    [J]. ENERGY AND BUILDINGS, 2013, 62 : 559 - 569
  • [4] Simulation and analysis of a novel liquid desiccant air-conditioning system
    Tu, Min
    Ren, Cheng-Qin
    Zhang, Long-Ai
    Shao, Jian-Wei
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) : 2417 - 2425
  • [5] Analysis on a hybrid desiccant air-conditioning system
    Jia, C. X.
    Dai, Y. J.
    Wu, J. Y.
    Wang, R. Z.
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) : 2393 - 2400
  • [6] Control strategies for a liquid desiccant air-conditioning system
    Ge, Gaoming
    Xiao, Fu
    Niu, Xiaofeng
    [J]. ENERGY AND BUILDINGS, 2011, 43 (06) : 1499 - 1507
  • [7] Thermodynamic analysis of a compression-absorption refrigeration air-conditioning system coupled with liquid desiccant dehumidification
    Su, Wei
    Zhang, Xiaosong
    [J]. APPLIED THERMAL ENGINEERING, 2017, 115 : 575 - 585
  • [8] Performance analysis of a novel multi-function liquid desiccant regeneration system for liquid desiccant air-conditioning system
    Cheng, Qing
    Xu, Wenhao
    [J]. ENERGY, 2017, 140 : 240 - 252
  • [9] Factor analysis and optimization of operational parameters in a liquid desiccant air-conditioning system
    Tu, Min
    Huang, Hui
    Liu, Ze-Hua
    Chen, Huan-Xin
    Ren, Cheng-Qin
    Chen, Guo-Jie
    Hu, Yan
    [J]. ENERGY, 2017, 139 : 767 - 781
  • [10] Exergy analysis of a liquid-desiccant-based, hybrid air-conditioning system
    Ahmed, CSK
    Gandhidasan, P
    Zubair, SM
    Al-Farayedhi, AA
    [J]. ENERGY, 1998, 23 (01) : 51 - 59