Direct mercury determination in blood and urine by means of high-resolution continuum source graphite furnace atomic absorption spectrometry using gold nanoparticles as a chemical modifier

被引:17
|
作者
Aramendia, Maite [1 ,2 ]
Guarda, Ananda [2 ]
Leite, Diego [2 ]
Resano, Martin [2 ]
机构
[1] Acad Gen Mil Zaragoza, Ctr Univ Def Zaragoza, Carretera Huesca S-N, Zaragoza 50090, Spain
[2] Univ Zaragoza, Dept Analyt Chem, Aragon Inst Engn Res I3A, Pedro Cerbuna 12, E-50009 Zaragoza, Spain
关键词
PALLADIUM NANOPARTICLES; SOLID SAMPLES; PERFORMANCE; SULFUR; SOILS; HG;
D O I
10.1039/c7ja00323d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of Hg in biological fluids, such as blood and urine, is important considering its known toxicity to human health. This kind of analysis typically requires the use of expensive instrumentation and/or sample pretreatment, which can be a problem for implementation in laboratories in low-and middle-income countries. In this work, a cost-effective methodology for the direct determination of Hg in blood and urine at low mu g L-1 levels by means of high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) is presented. This method is based on the use of Au nanoparticles (Au NPs) as a modifier, which can be readily synthesized in any basic laboratory. By using this modifier, direct analysis of one sample can be performed in a few minutes without the need for extensive sample pretreatment and calibrating with aqueous standards. Although developed for HR CS GFAAS, this method might be adopted by any laboratory equipped with any GFAAS instrument. With our instrumentation, a characteristic mass of 16 pg and a LOD of 2.3 mu g L-1 (for a typical sample volume of 10 mL, although higher volumes can also be analyzed, if required) was obtained for Hg, which is fit for purpose in the context of Hg exposure monitoring as a result of occupational hazards.
引用
收藏
页码:2352 / 2359
页数:8
相关论文
共 50 条
  • [1] Direct determination of sulfur in solid samples by means of high-resolution continuum source graphite furnace molecular absorption spectrometry using palladium nanoparticles as chemical modifier
    Resano, Martin
    Florez, Maria R.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (03) : 401 - 412
  • [2] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355
  • [3] Application of Disposable Pipette Extraction for Determination of Yb by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier
    Betiolo, Diogo M.
    Cadorim, Heloisa R.
    Carasek, Eduardo
    Maranhao, Tatiane A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (08) : 1087 - 1099
  • [4] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martin
    Garcia-Ruiz, Esperanza
    Garde, Raul
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2233 - 2241
  • [5] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martín (mresano@unizar.es), 1600, Royal Society of Chemistry (31):
  • [6] Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Pereira, Ederson R.
    de Almeida, Tarcisio S.
    Borges, Daniel L. G.
    Carasek, Eduardo
    Welz, Bernhard
    Feldmann, Joerg
    del Campo Menoyo, Javier
    TALANTA, 2016, 150 : 142 - 147
  • [7] Determination of Cu in blood via direct analysis of dried blood spots using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Garcia-Poyo, M. Carmen
    Pecheyran, Christophe
    Rello, Luis
    Garcia-Gonzalez, Elena
    Alonso Rodriguez, Sharay
    Nakadi, Flavio V.
    Aramendia, Maite
    Resano, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (08) : 1666 - 1677
  • [8] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107
  • [9] Determination of Lead in Coal Using Direct Solid Sampling and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Daniel L. Gallindo Borges
    Alessandra Furtado da Silva
    Adilson José Curtius
    Bernhard Welz
    Uwe Heitmann
    Microchimica Acta, 2006, 154 : 101 - 107
  • [10] Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry
    Lepri, Fabio G.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Borges, Daniel L. G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 934 - 944