Direct mercury determination in blood and urine by means of high-resolution continuum source graphite furnace atomic absorption spectrometry using gold nanoparticles as a chemical modifier

被引:17
|
作者
Aramendia, Maite [1 ,2 ]
Guarda, Ananda [2 ]
Leite, Diego [2 ]
Resano, Martin [2 ]
机构
[1] Acad Gen Mil Zaragoza, Ctr Univ Def Zaragoza, Carretera Huesca S-N, Zaragoza 50090, Spain
[2] Univ Zaragoza, Dept Analyt Chem, Aragon Inst Engn Res I3A, Pedro Cerbuna 12, E-50009 Zaragoza, Spain
关键词
PALLADIUM NANOPARTICLES; SOLID SAMPLES; PERFORMANCE; SULFUR; SOILS; HG;
D O I
10.1039/c7ja00323d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of Hg in biological fluids, such as blood and urine, is important considering its known toxicity to human health. This kind of analysis typically requires the use of expensive instrumentation and/or sample pretreatment, which can be a problem for implementation in laboratories in low-and middle-income countries. In this work, a cost-effective methodology for the direct determination of Hg in blood and urine at low mu g L-1 levels by means of high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) is presented. This method is based on the use of Au nanoparticles (Au NPs) as a modifier, which can be readily synthesized in any basic laboratory. By using this modifier, direct analysis of one sample can be performed in a few minutes without the need for extensive sample pretreatment and calibrating with aqueous standards. Although developed for HR CS GFAAS, this method might be adopted by any laboratory equipped with any GFAAS instrument. With our instrumentation, a characteristic mass of 16 pg and a LOD of 2.3 mu g L-1 (for a typical sample volume of 10 mL, although higher volumes can also be analyzed, if required) was obtained for Hg, which is fit for purpose in the context of Hg exposure monitoring as a result of occupational hazards.
引用
收藏
页码:2352 / 2359
页数:8
相关论文
共 50 条
  • [21] Determination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
    Krawczyk, Magdalena
    Matusiewicz, Henryk
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (05) : 749 - 757
  • [22] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [23] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    Da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (08): : 763 - 769
  • [24] Determination of Pb and Cr in sunscreen samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct analysis
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Duarte, Alvaro T.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2016, 128 : 89 - 94
  • [25] Direct determination of Zn in individual Daphnia magna specimens by means of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Briceno, J.
    Belarra, M. A.
    De Schamphelaere, K. A. C.
    Vanblaere, S.
    Janssen, C. R.
    Vanhaecke, F.
    Resano, M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 503 - 510
  • [26] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [27] Determination of selenium in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Castilho, Ivan N. B.
    Pereira, Ederson R.
    Welz, Bernhard
    Shaltout, Abdallah A.
    Caraseka, Eduardo
    Martensd, Irland B. Gonzaga
    ANALYTICAL METHODS, 2014, 6 (09) : 2870 - 2875
  • [28] Determination of Chlorine in Milk via Molecular Absorption of SrCI Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (28) : 5767 - 5772
  • [29] Determination of Antimony in Pharmaceutical Formulations and Beverages Using High-Resolution Continuum-Source Graphite Furnace Atomic Absorption Spectrometry
    Mattiazzi, Patricia
    Bohrer, Denise
    Viana, Carine
    do Nascimento, Paulo Cicero
    Veiga, Marlei
    de Carvalho, Leandro Machado
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 737 - 743
  • [30] Direct determination of bromine in plastic materials by means of solid sampling high-resolution continuum source graphite furnace molecular absorption spectrometry
    Florez, M. R.
    Resano, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 88 : 32 - 39