Incidence, indications and predicting factors of permanent pacemaker implantation after transcatheter aortic valve implantation: A retrospective study

被引:17
|
作者
Becker, Mathieu [1 ]
Blangy, Hugues [1 ]
Folliguet, Thierry [1 ,2 ]
Villemin, Thibault [1 ,2 ]
Freysz, Luc [1 ]
Luc, Amandine [3 ]
Maureira, Pablo [1 ,2 ]
Popovic, Batric [1 ]
Olivier, Arnaud [1 ,2 ]
Sadoul, Nicolas [1 ,2 ]
机构
[1] CHU Nancy, Dept Cardiol, F-54511 Vandoeuvre Les Nancy, France
[2] Univ Lorraine, F-54000 Nancy, France
[3] Univ Hosp Nancy, PARC, ESPRI Biobase Unit, F-54511 Vandoeuvre Les Nancy, France
关键词
Transcatheter aortic valve implantation; Aortic stenosis; Permanent pacemaker implantation; Predicting factors; Incidence; BUNDLE-BRANCH BLOCK; INTRAVENTRICULAR-CONDUCTION DISTURBANCES; HEART-ASSOCIATION ELECTROCARDIOGRAPHY; MULTIDETECTOR COMPUTED-TOMOGRAPHY; BALLOON-EXPANDABLE VALVE; OF-CARDIOLOGY-FOUNDATION; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; CLINICAL CARDIOLOGY; RHYTHM-SOCIETY;
D O I
10.1016/j.acvd.2017.03.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - As the number of transcatheter aortic valve implantation (TAVI) procedures is constantly increasing, it is important to consider common complications, such as pacemaker (PM) implantation, and their specific risk factors. Aims. - Echocardiographic, computed tomography and electrocardiographic data were analysed to determine the predicting factors, if any, associated with PM implantation. Methods.- This retrospective study included patients referred to Nancy University Hospital for a TAVI procedure from January 2013 to December 2015. Both Medtronic CoreValve and Edwards SAPIEN valves were implanted. Patients with preprocedurally implanted PMs and/or referred from another institution were excluded. Results. - Of 208 TAVI patients, 23 had a pre-existing PM and were excluded. A new PM was required in 38 patients (20.5%). Pre-existing right bundle branch block (RBBB), the use of the Medtronic CoreValve and large prostheses were identified as predictors of PM implantation (P=0.0361, P=0.0004 and P=0.0019,respectively). Using logistic regression, predictors of PM implantation included first-degree atrioventricular block (odds ratio 3.7, 95% confidence interval 1.5-9.1; P=0.0054) and large aortic annulus diameter in echocardiography (odds ratio 1.2, 95% confidence interval 1-1.4; P=0.0447), with a threshold of 24.1 mm. For the combination of preTAVI PR duration > 220 ms and QRS duration > 120 ms, the positive predictive value for PM implantation reached 80%. Conclusion. - Use of the Medtronic CoreValve, RBBB and first-degree atrioventricular block are major risk factors for post-TAVI PM implantation. In addition, large aortic annulus and large valvular prosthesis are independent risk factors for PM implantation. The combination of preTAVI prolonged PR interval and increased QRS duration could be used as a marker for periprocedural PM implantation. (C) 2017 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:508 / 516
页数:9
相关论文
共 50 条
  • [31] Comparison of permanent pacemaker implantation rate after first and second generation of transcatheter aortic valve implantation-A retrospective cohort study
    Minha, Sa'ar
    Yarkoni, Yuval
    Segev, Amit
    Finkelstein, Ariel
    Danenberg, Haim
    Fefer, Paul
    Orvin, Katia
    Steinvil, Arie
    Maor, Elad
    Beinart, Roy
    Rosso, Raphael
    Golovchiner, Gregory
    Kornowski, Ran
    Guetta, Victor
    Barbash, Israel M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (07) : E990 - E999
  • [32] Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry
    Rudolph, Tanja
    Droppa, Michal
    Baan, Jan
    Nielsen, Niels-Erik
    Baranowski, Jacek
    Hachaturyan, Violetta
    Kurucova, Jana
    Hack, Luis
    Bramlage, Peter
    Geisler, Tobias
    OPEN HEART, 2023, 10 (01):
  • [33] Transcatheter Aortic Valve Implantation: Addressing the Subsequent Risk of Permanent Pacemaker Implantation
    Lauten, Philipp
    Costello-Boerrigter, Lisa C.
    Goebel, Bjoern
    Gonzalez-Lopez, David
    Schreiber, Matthias
    Kuntze, Thomas
    Al Jassem, Mahmoud
    Lapp, Harald
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (06)
  • [34] Permanent Pacemaker Insertion After CoreValve Transcatheter Aortic Valve Implantation Incidence and Contributing Factors (the UK CoreValve Collaborative)
    Khawaja, M. Z.
    Rajani, R.
    Cook, A.
    Khavandi, A.
    Moynagh, A.
    Chowdhary, S.
    Spence, M. S.
    Brown, S.
    Khan, S. Q.
    Walker, N.
    Trivedi, U.
    Hutchinson, N.
    De Belder, A. J.
    Moat, N.
    Blackman, D. J.
    Levy, R. D.
    Manoharan, G.
    Roberts, D.
    Khogali, S. S.
    Crean, P.
    Brecker, S. J.
    Baumbach, A.
    Mullen, M.
    Laborde, J. -C.
    Hildick-Smith, D.
    CIRCULATION, 2011, 123 (09) : 951 - U47
  • [35] Effect of Pacemaker Implantation After Transcatheter Aortic Valve Implantation Compared to Surgical Aortic Valve Implantation
    Annie, Frank H.
    Dave, Sahil
    Muhammad, Syed
    Nanjundappa, Aravinda
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 164 : 133 - 133
  • [36] Effect of Pacemaker Implantation After Transcatheter Aortic Valve Implantation Compared to Surgical Aortic Valve Implantation
    Annie, Frank H.
    Dave, Sahil
    Muhammad, Syed
    Nanjundappa, Aravinda
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 164 : 133 - 133
  • [37] Prognostic impact of permanent pacemaker implantation after transcatheter aortic valve replacement
    Sharobeem, Sam
    Boulmier, Dominique
    Leurent, Guillaume
    Bedossa, Marc
    Leclercq, Christophe
    Mabo, Philippe
    Martins, Raphael P.
    Tomasi, Jacques
    Verhoye, Jean-Philippe
    Donal, Erwan
    Sost, Gwenaelle
    Le Guellec, Marielle
    Le Breton, Herve
    Auffret, Vincent
    HEART RHYTHM, 2022, 19 (07) : 1124 - 1132
  • [38] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Qi, Yiming
    Lin, Xiaolei
    Pan, Wenzhi
    Zhang, Xiaochun
    Ding, Yuefan
    Chen, Shasha
    Zhang, Lei
    Zhou, Daxin
    Ge, Junbo
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [39] Quality Control for Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Yazdchi, Farhang
    Hirji, Sameer
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2020, 110 (01): : 347 - 348
  • [40] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Yiming Qi
    Xiaolei Lin
    Wenzhi Pan
    Xiaochun Zhang
    Yuefan Ding
    Shasha Chen
    Lei Zhang
    Daxin Zhou
    Junbo Ge
    European Journal of Medical Research, 28