Prognostic impact of permanent pacemaker implantation after transcatheter aortic valve replacement

被引:7
|
作者
Sharobeem, Sam [1 ]
Boulmier, Dominique [1 ]
Leurent, Guillaume [1 ]
Bedossa, Marc [1 ]
Leclercq, Christophe [1 ]
Mabo, Philippe [1 ]
Martins, Raphael P. [1 ]
Tomasi, Jacques [2 ]
Verhoye, Jean-Philippe [2 ]
Donal, Erwan [1 ]
Sost, Gwenaelle [3 ]
Le Guellec, Marielle [1 ]
Le Breton, Herve [1 ]
Auffret, Vincent [1 ]
机构
[1] Univ Rennes 1, CHU Rennes, Serv Cardiol, Inserm LTSI U1099, Rennes, France
[2] Univ Rennes 1, CHU Rennes, Serv Chirurg Cardiaque, Inserm LTSI U1099, Rennes, France
[3] Univ Rennes 1, Serv Geriatr, CHU Rennes, Rennes, France
关键词
Aortic stenosis; TAVR; Conduction disturbances; Permanent pacemaker implantation; Heart failure; CONDUCTION DISTURBANCES; CLINICAL-OUTCOMES; DISEASE; PREDICTORS; MANAGEMENT; COLLEGE; BLOCK;
D O I
10.1016/j.hrthm.2022.03.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Conduction disturbances requiring permanent pacemaker implantation (PPI) remain a common complication of transcatheter aortic valve replacement (TAVR). OBJECTIVE The purpose of this study was to determine the prognostic impact of PPI after TAVR according to the timing of implantation relative to TAVR. METHODS A total of 1199 patients (median age 83 years; interquartile range 78-86 years; 549 [45.8%] female) were included in the analysis, of whom 894 (70.8%) had not undergone PPI, 130 (10.8%) had undergone previous PPI, 116 (9.7%) had undergone in-hospital PPI, and 59 (4.9%) had undergone PPI during followup. Median follow-up was 2.94 years (1.42-4.32 years). The primary outcome was the composite of all-cause mortality and hospitalization for heart failure. RESULTS PPI during follow-up was associated with a higher occurrence of the primary outcome (hazard ratio [HR] 2.11; 95% confidence interval [CI] 1.39-3.20) whereas previous PPI and in-hospital PPI were not (HR 0.96; 95% CI 0.71-1.29 and HR 1.26; 95% CI 0.88-1.81, respectively). PPI during follow-up was associated with a higher risk of hospitalization for heart failure (sub-HR 3.21; 95% CI 2.02-5.11), while this relationship was only borderline significant for previous PPI (sub-HR 1.51; 95% CI 0.99-2.29). In contrast, there was no relationship between in-hospital PPI and the subsequent risk of hospitalization for heart failure. CONCLUSION Previous PPI and in-hospital PPI had no long-term prognostic impact on the risk of all-cause mortality and hospitalization for heart failure, whereas PPI during follow-up was associated with a higher risk of hospitalization for heart failure. The present study questions the deleterious influence of periprocedural post-TAVR PPI, which has previously been suggested by certain studies.
引用
收藏
页码:1124 / 1132
页数:9
相关论文
共 50 条
  • [1] Prognostic impact of new permanent pacemaker implantation following transcatheter aortic valve replacement
    Zheng, Hua-Jie
    Yan, Chao-Jun
    Lin, De-Qing
    Cheng, Yong-Bo
    Yu, San-Jiu
    Li, Jun
    Zhang, Xian-Pu
    Cheng, Wei
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (04) : 743 - 750
  • [2] Prognostic effect of permanent pacemaker implantation on mortality after transcatheter aortic valve replacement
    Engborg, J.
    Olson, F.
    Riechel-Sarup, C.
    Lauritsen, M. T.
    Gerke, O.
    Mickley, H.
    Sandgaard, N.
    Nissen, H.
    Diederichsen, A. C. P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1051 - 1051
  • [3] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Hoyt, Matthew J.
    Hathaway, Jessica
    Palmer, Roseanne
    Beach, Michael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1162 - 1166
  • [4] Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients
    Xiong, Tian-Yuan
    Liao, Yan-Biao
    Li, Yi-Jian
    Zhao, Zhen-Gang
    Wei, Xin
    Tsauo, Jiay-yu
    Xu, Yuan-Ning
    Feng, Yuan
    Chen, Mao
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 878 - 884
  • [5] Impact of periprocedural permanent pacemaker implantation on clinical outcomes after transcatheter aortic valve replacement
    Xi, Ziwei
    Zhou, Yujie
    Liu, Wei
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C178 - C178
  • [6] THE IMPACT OF PERMANENT PACEMAKER IMPLANTATION FOLLOWING TRANSCATHETER AORTIC VALVE REPLACEMENT ON OUTCOME
    Pereira, Marco Magalhaes
    Minha, Sa'ar
    Alarcon, Ricardo Escarcega
    Baker, Nevin
    Ota, Hideaki
    Omar, Al Fazir
    Pendyala, Lakshmana
    Loh, Joshua
    Rodriguez-Weisson, Jose F.
    Torguson, Rebecca
    Chen, Fang
    Ben-Dor, Itsik
    Okubagzi, Petros
    Suddath, William
    Satler, Lowell
    Pichard, Augusto
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1735 - A1735
  • [7] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Qi, Yiming
    Lin, Xiaolei
    Pan, Wenzhi
    Zhang, Xiaochun
    Ding, Yuefan
    Chen, Shasha
    Zhang, Lei
    Zhou, Daxin
    Ge, Junbo
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [8] Incidence and determinants of permanent pacemaker implantation after transcatheter aortic valve replacement
    Bellantoni, Antonio
    Sorrentino, Sabato
    Boccuto, Fabiola
    Carabett, Nicole
    Giordano, Salvatore
    Cacia, Michele Antonio
    Polimeni, Alberto
    Leo, Isabella
    Varano, Ylenia
    Augusto, Florinda Maria
    Mongiardo, Annalisa
    De Rosa, Salvatore
    Indolfi, Ciro
    Spaccarotella, Carmen
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [9] Incidence and determinants of permanent pacemaker implantation after transcatheter aortic valve replacement
    Bellantoni, Antonio
    Sorrentino, Sabato
    Boccuto, Fabiola
    Carabett, Nicole
    Giordano, Salvatore
    Cacia, Michele Antonio
    Polimeni, Alberto
    Leo, Isabella
    Varano, Ylenia
    Augusto, Florinda Maria
    Mongiardo, Annalisa
    De Rosa, Salvatore
    Indolfi, Ciro
    Spaccarotella, Carmen
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G) : G196 - G196
  • [10] Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Cost Analysis
    Ahmad, Mansoor
    Patel, Jay N.
    Loc, Brian L.
    Vipparthy, Sharath C.
    Divecha, Chirag
    Barzallo, Pablo X.
    Kim, Minchul
    Baman, Timir
    Barzallo, Marco
    Mungee, Sudhir
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)