Characteristics of a mixed-gas cluster ion beam for time-of-flight secondary ion mass spectrometry

被引:7
|
作者
Lee, Sang Ju [1 ]
Hong, Aram [1 ]
Cho, Jinwan [1 ]
Choi, Chang Min [1 ]
Baek, Ji Young [1 ]
Eo, Jae Yeong [2 ]
Cha, Byeong Jun [1 ]
Byeon, Woo Jun [1 ]
We, Jin Young [1 ]
Hyun, Sangwon [2 ]
Jeon, Minwoo [2 ]
Jeon, Choelho [3 ]
Ku, Dong Jin [4 ]
Choi, Myoung Choul [1 ]
机构
[1] Korea Basic Sci Inst, Ctr Sci Instrumentat, Cheongju, South Korea
[2] Korea Basic Sci Inst, Ctr Res Equipment, Daejeon, South Korea
[3] Korea Basic Sci Inst, Res Ctr Mat Anal, Daejeon, South Korea
[4] Y&DK Co Ltd, Ultraprecis Tech Res Inst, Daejeon, South Korea
关键词
Mixed-gas duster ion beam; Time-of-flight secondary ion mass spectrometry; CO2; clusters; Mass spectra; TOF-SIMS;
D O I
10.1016/j.apsusc.2021.151467
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The gas cluster ion beam (GCIB) is a valuable tool for surface analysis, providing new 3D mass analysis equipment possibilities. The main feature of the GCIB is that many particles are involved during the collision of the cluster ion beam with a sample surface. Studying the characteristics of the GCIB is essential for improving the performance of the analysis equipment. We evaluated the efficiency of the GCIB using a mixed-gas of Ar and CO2 as a primary ion beam for time-of-flight secondary ion mass spectrometry. We measured the characteristic factors and composition of the cluster ion beam depending on the mole fraction ratio of CO2/Ar. We measured that the CO2 composition of the output cluster ion beam rapidly increases to over 95% when the mole fraction ratio of CO2 increases by more than 10% in the injected mixed gas. Nevertheless, the optimal ratio of the CO2/Ar mole fraction (%) to increase the secondary ion efficiency was 96% CO2, which more than doubled the secondary ion efficiency over that of pure Ar clusters. The beam spot size began rapidly decreasing from 95% CO2, and it was reduced by up to 0.67 times at 100% CO2. According to the mixed-gas ratio, the sputtering yield of the Si wafer was 8 times lower than that of pure Ar clusters.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Lipid imaging with cluster time-of-flight secondary ion mass spectrometry
    Alain Brunelle
    Olivier Laprévote
    Analytical and Bioanalytical Chemistry, 2009, 393
  • [2] Lipid imaging with cluster time-of-flight secondary ion mass spectrometry
    Brunelle, Alain
    Laprevote, Olivier
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) : 31 - 35
  • [3] Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources
    Brunelle, A
    Touboul, D
    Laprévote, O
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08): : 985 - 999
  • [4] Time-of-flight secondary ion mass spectrometry of fullerenes
    Saldi, F
    Marie, Y
    Gao, Y
    Simon, C
    Migeon, HN
    Begin, D
    Mareche, JF
    EUROPEAN MASS SPECTROMETRY, 1995, 1 (05): : 487 - 492
  • [5] SECONDARY ION MASS-SPECTROMETRY BY TIME-OF-FLIGHT
    STANDING, KG
    BEAVIS, R
    ENS, W
    SCHUELER, B
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 53 (SEP): : 125 - 134
  • [6] Time-of-flight secondary ion mass spectrometry in the helium ion microscope
    Klingner, N.
    Heller, R.
    Hlawacek, G.
    Facsko, S.
    von Borany, J.
    ULTRAMICROSCOPY, 2019, 198 : 10 - 17
  • [7] Three-Dimensional Image of Cleavage Bodies in Nuclei Is Configured Using Gas Cluster Ion Beam with Time-of-Flight Secondary Ion Mass Spectrometry
    Noritaka Masaki
    Itsuko Ishizaki
    Takahiro Hayasaka
    Gregory L. Fisher
    Noriaki Sanada
    Hideo Yokota
    Mitsutoshi Setou
    Scientific Reports, 5
  • [8] Three-Dimensional Image of Cleavage Bodies in Nuclei Is Configured Using Gas Cluster Ion Beam with Time-of-Flight Secondary Ion Mass Spectrometry
    Masaki, Noritaka
    Ishizaki, Itsuko
    Hayasaka, Takahiro
    Fisher, Gregory L.
    Sanada, Noriaki
    Yokota, Hideo
    Setou, Mitsutoshi
    SCIENTIFIC REPORTS, 2015, 5
  • [9] Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations
    Angerer, Tina B.
    Velickovic, Dusan
    Nicora, Carrie D.
    Kyle, Jennifer E.
    Graham, Daniel J.
    Anderton, Christopher
    Gamble, Lara J.
    ANALYTICAL CHEMISTRY, 2019, 91 (23) : 15073 - 15080
  • [10] Time-of-flight secondary ion mass spectroscopy for surface analysis of insulators using a cluster ion beam
    Hirata, K
    Saitoh, Y
    Chiba, A
    Narumi, K
    Kobayashi, Y
    Arakawa, K
    APPLIED PHYSICS LETTERS, 2003, 83 (23) : 4872 - 4874