New method for evaluating maximal respiratory pressures: Concurrent validity, test-retest, and inter-rater reliability

被引:8
|
作者
Silveira, Bruna M. F. [1 ]
Pereira, Manoel C. B. [2 ]
Cardoso, Daniella R. [3 ]
Ribeiro-Samora, Giane A. [1 ]
Martins, Henrique R. [4 ]
Parreira, Veronica F. [3 ]
机构
[1] Univ Fed Minas Gerais, Rehabil Sci Program, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Elect Engn Program, Belo Horizonte, MG, Brazil
[3] Univ Fed Minas Gerais, Dept Phys Therapy, Ave Antonio Carlos,6627 Pampulha, BR-31270901 Belo Horizonte, MG, Brazil
[4] Univ Fed Minas Gerais, Dept Elect Engn, Belo Horizonte, MG, Brazil
关键词
Chronic obstructive; pulmonary disease; Functional residual capacity; Measurement properties; Physical therapy; Respiratory muscles; DIAPHRAGM; STRENGTH;
D O I
10.1016/j.bjpt.2021.04.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Maximal respiratory pressures (MRP) obtained at functional residual capacity (FRC) may reflect the real respiratory muscle pressure. Objectives: To evaluate concurrent validity, test-retest, and inter-rater reliability of MRP performed with a new instrument in healthy individuals, and to compare values obtained at different volumes in healthy individuals and individuals with COPD. Methods: MRP of 100 healthy individuals were obtained using the TrueForce and the MicroRPM (R) at residual volume (RV) and total lung capacity (TLC) to evaluate concurrent validity. MRP were obtained at FRC using the TrueForce to evaluate reliability. Comparisons of inspiratory pressure values (FRC compared to RV) and expiratory pressure values (FRC compared to TLC) were performed with 100 healthy individuals and 15 individuals with COPD. Results: The intraclass correlation coefficient (ICC) was 0.77 and 0.86 for concurrent validity for inspiratory and expiratory pressures, respectively. Test- retest reliability showed an ICC of 0.87 for inspiratory pressure, and 0.78 for expiratory pressure; inter-rater reliability showed an ICC of 0.91 for inspiratory pressure, and 0.84 for expiratory pressure. Measurements performed at RV and TLC were higher when compared to FRC [mean difference (95%CI)= -8.30 (- 11.82, -4.78) cmH(2)O; -37.29 (-42.63, -31.96) cmH(2)O] in healthy individuals, and -11.09 (- 15.83, -6.35) cmH(2)O; -57.14 (-71.05, -43.05) cmH(2)O in COPD, for inspiratory and expiratory pressures, respectively. Conclusion: MRP performed with the TrueForce presented good concurrent validity, good testretest reliability, excellent inter-rater reliability for inspiratory pressure and good inter-rater reliability for expiratory pressure. MRP were lower when obtained at FRC for healthy individuals and with COPD. (C) 2021 Associacao Brasileira de Pesquisa e Pos-Graduacao em Fisioterapia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:741 / 748
页数:8
相关论文
共 50 条
  • [41] Evaluation of inter-rater and test-retest reliability for near-infrared spectroscopy reactive hyperemia measures
    McGranahan, Melissa J.
    Kibildis, Samuel W.
    McCully, Kevin K.
    O'Connor, Patrick J.
    MICROVASCULAR RESEARCH, 2023, 148
  • [42] Preschool Behavioral and Emotional Rating Scale (PreBERS): Test-Retest and Inter-Rater Reliability for Children with Disabilities
    Cress, Cynthia J.
    Epstein, Michael H.
    Synhorst, Lori
    EXCEPTIONALITY, 2010, 18 (02) : 58 - 69
  • [43] Inter-Rater and Test-Retest Reliability, Internal Consistency, and Factorial Structure of the Instrument for Forensic Treatment Evaluation
    Schuringa, Erwin
    Spreen, Marinus
    Bogaerts, Stefan
    JOURNAL OF FORENSIC PSYCHOLOGY PRACTICE, 2014, 14 (02) : 127 - 144
  • [44] Inter-Rater and Test-Retest Reliability of the German Pediatric Evaluation of Disability Inventory (PEDI-G)
    Schulze, Christina
    Kottorp, Anders
    Meichtry, Andre
    Lilja, Margareta
    Page, Julie
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2015, 35 (03) : 296 - 310
  • [45] Test-retest reliability and inter-rater reliability of the Modified Tardieu Scale and the Modified Ashworth Scale in hemiplegic patients with stroke
    Li, F.
    Wu, Y.
    Li, X.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2014, 50 (01) : 9 - 15
  • [46] Submaximal exercise in persons with stroke: Test-retest reliability and concurrent validity with maximal oxygen consumption
    Eng, JJ
    Dawson, AS
    Chu, KS
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (01): : 113 - 118
  • [47] Concurrent validity and test-retest reliability of the information processing styles
    Baloglu, M
    Zelhart, PF
    PSYCHOLOGICAL REPORTS, 2000, 87 (03) : 973 - 979
  • [48] Inter-rater and test-retest reliability of three contingent valuation question formats in south-east Nigeria
    Onwujekwe, O
    Fox-Rushby, J
    Hanson, K
    HEALTH ECONOMICS, 2005, 14 (05) : 529 - 536
  • [49] Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson's Disease
    van Lummel, Rob C.
    Walgaard, Stefan
    Hobert, Markus A.
    Maetzler, Walter
    van Dieen, Jaap H.
    Galindo-Garre, Francisca
    Terwee, Caroline B.
    PLOS ONE, 2016, 11 (03):
  • [50] Test-Retest and Inter-Rater Reliability of Isokinetic Ankle Dorsiflexor and Plantar Flexor Strength Measurement in Healthy Adults
    Ozyemisci Taskiran, Ozden
    Ozdodan, Vildan
    Sepici, Vesile
    Meray, Jale
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2013, 59 (01): : 32 - 35